Loading...
HomeMy WebLinkAboutEngineered Plan - 2018LEGEND _ - 99 - EXISTING CONTOUR X 99. 1 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR 198.4] PROPOSED SPOT EL. TH1 "2'1__ TEST HOLE SLOPE OF GROUND CO, UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED 1676 S.F. OFFICE @ 75 GPD/1000 S.F. = 126 GPD TOTAL DESIGN FLOW ESTIMATE = 126 GPD USE A MIN. OF 200 GPD I SEPTIC TANK: 200 GPD (2) = 400 USE A 1500 GAL. DUAL COMPARTMENT SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND MA APPROVED DATE BOARD OF HEALTH SYSTEM PROFILEALL SHALL MARK DSTEWITHCMAGNETIC TTAPE OR BE NOTES /' d Roo Sl (NOT TO SCALE) COMPARABLE MEANS FOR FUTURE LOCATION. ° PROVIDE MIN. 20" DIAM. WATERTIGHT 1. DATUM IS NAVD 88 0 n �o ACCESS COVERS TO WITHIN 6" OF FIN. GRADE CONCRETE COVERS TO WITHIN 3" GRADE ° 2" PEASTONE OR GEOTEXTILE 2. MUNICIPAL WATER IS EXISTING TOP FOUND. EL. 17.4 FILTER FABRIC OVER STONE 2% SLOPE REQUIRED OVER SYSTEM 17.0 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. �P R 28 \ MINIMUM .75' OF COVER OVER PRECAST c�� ° to Locus o 3 NOTE: 2" MIN. WALL 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS PRECAST H-10 THICKNESS REQUIRED BLOCKS OR TO BE AASHO H-20 (H-10 TANK) ` 5`• RISERS (TYP.) PRECAST RISERS � 2'0 4"OSCH40 PVC MORTAR ALL H-20 o`n \ PIPES LEVEL 1ST 2' COMPONENTS 5. PIPE JOINTS TO BE MADE WATERTIGHT. a p\d 5 • J�'� 0olco� ,.: r^.� 6" MIN. SUMP 4' (Np) INV'S EL. 13.2 1500 GAL H-10 12" MIN. INT. DIM. ENDS SIDES 14.2' 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH oh ti * 14.3' DUAL COMPARTMENT 14. ➢oo�oo�' 310 CMR 15.000 (TITLE 5.) o Q�e Jco\ 13.82 T�E SEPTIC TANK TEE 13.57' { °°°°°°o° ��OO 0 ���0 �O�O �D�O ;00000000 aSS ° ° �000�P13 00000000000 °°O000C 1ST °o°o°o ° ° 0 7. THIS PLAN 1S FOR PROPOSED WORK ONLY AND NOT TO omin 0 0 0 0 0 o WATERTE$T D'BQX 00�0000000� >°o°o°o°o ° ° ° ° ° ° ° ° BE USED FOR LOT LINE STAKING OR ANY OTHER COMPARTMENT :� GAS BAFFLE .:. 2ND m 00000 0 0_ FOR LEVELNESS N >00000000 DODOCoO� 000�OC�O� QQQQQ��0000 'o°o°O°o° '. MIN. 400 GAL. COMPARTMENT , 00000000 %'00000000 1 1.2' PURPOSE. 4' LIQ. LEVEL `, ACME OR EQUAL''; MIN. 200 GAL. 13.30 ? 13.47' 1 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. JO°000°°°°°°°°°0°°0°°°°o°°Oo°°°°°o°°°°°o°o°°� N C 0 00000 0 0 0 0 0000000000000 0 0 0 0 0 0 0 0 H-20 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. ? 010000n0n0n010100000�0�00000�0°00000, 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. (2) UNITS REQUIRED 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL;; DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' WITHOUT INSPECTION BY BOARD OF HEALTH AND � ;.� PERMISSION OBTAINED FROM BOARD OF HEALTH. COMPACTION. (15.221 [21) a 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING q DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCUS MAP OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. I 5.9' BOTTOM TH-1 SCALE 1 "=2000't ( 2.5% SLOPE MIN.) ( 1 %SLOPE) (1 % SLOPE) NO GROUNDWATER FOUND 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED ASSESSORS MAP 51 PARCEL 38 FOUNDATION- 18' SEPTIC TANK 10' D' BOX 12' LEACHING LEACHING FACILITY. FACILITY j 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND LOCUS IS WITHIN FEMA FLOOD ZONE X REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001 CO587J DATED 7/16/2014 r Date DANIEL o A. nr 9 DANIELA. r OJALA OJALA !: +10 _ o No. 40980I CIVIL `. �o 1*. 4` No. 46502 FfiS5�0 )o .,, IPA, F�� ra OF G/S1 ER \J _....... ; i a7 4 DATE DANIEL A. OJALA, P.E., P.L.S. l� TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE # 13871 WITWFCC• PHIL RENAUD DATE: 10/ 18/ 18 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. ELEV. 0" 16.9' 0" 16.9' A FILL LS _.. 10YR 42 B B LS LS 16" 1OYR 5/6 15.6' 18„ 1OYR 5/6 15.4' C C PERC FS MS 10YR 7/4 1OYR 7/4 132" 1 5.9' 132" I 5.9' NO GROUNDWATER ENCOUNTERED mw u iunmoM� � me i' uwuwcmn PREPARED FOR � "'EORG"'- DAVS .m L__ DATE: OCTOBER 25, 2018 Scale:1 "= 20' 1� 0 10 20 30 40 50 FEET off 508-362-4541 fox 508-362-9880 downcope.com o w,7 nape n eh erin , td��e (ropcivil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 18-359 DAVIS.DWG j DCE ## 18-359