HomeMy WebLinkAboutEngineered Plan - 20181.2' PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE MINIMUM .75' OF COVER OVER PRECAST PRECAST H-10 28.5' RISERS (TYP.) IIt 2'0 U 10" "EXISTING 14" TEE SEPTIC TANK TEE GAS BAF 4' LIQ. LEVEL (ACME OR EQL **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE —USE. REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE FOUNDATION EXIST. LEGEND 99 — EXISTING CONTOUR X 99• 1 EXIST. SPOT ELEV. —[99]-- PROPOSED CONTOUR 198.4] PROPOSED SPOT EL. TH1 TEST HOLE 2� SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE. NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE # 13871 WITNESS: AMY VON HONE, RS DATE: 10/ 17/2018 PERC. RATE = < 2 MIN/INCH CLASS ' SOILS . � ELEV. p1 28.5' A LS 12" 1OYR 4/1 B LS 42„ 1OYR 5/6 25' C PERC MS 1OYR 7/4 144" I 116.5' NO GROUNDWATER ENCOUNTERED ICE # 18-368 SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM 28-29' NOTE: 2" MIN. WALL THICKNESS REQUIRED BLOCKS OR 4"OSCH40 PVC MORTAR ALL PRECAST RISERS 6" MIN. SUMP PIPES LEVEL 1ST 2' COMPONENTS H-10 12" MIN. INT. DIM. � ENDS (NP.) SIDES 26.03' eoaoao<. )„O O O O f�� '> 0 0 0 0 0 �0016 �60�—i 0 —Q��� >00000000 7—\*27.2' ° ° o ° o. ° WATERTEHT D'BOX 'o°o°o°o° CI��ODaO�OO� �OOo �aa�OaOo a '>'00000" 0 00000000000O >o°o°o°o° O O O O O O O O O O O O O O O O O O O 'o°o°o°o° °° ° ° ° ° o�ooaoaoao� aaoaooao�oo ° ° ° ° LE °�o�gFOR LEVELNESS (V >00000000 00000000 >00000000 ��aa l-I ��I�o IJI'_I I�.II�I�a �a I� I� I] IJ I 00000000 , 25.47' 25.30' °°°°°°°° 23.2 L) > o o 0 0 0 0 0 0 3/4"-1-1/2" L H-10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. DOUBLE WASHED STONE 4' MIN. (2) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15.221 [2]) ( 3.7 % SLOPE) ( 1 % SLOPE) SEPTIC TANK 47' D' BOX 12' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING. ANY PORTION OF SEPTIC SYSTEM FLOOR PLAN NOT TO SCALE Scale:1 "= 20' 0 10 20 30 40 50 FEET LEACHING FACILITY 16.5' BOTTOM TH-1 NO GROUNDWATER FOUND i p —\-1-- e> DATE Rol Iw 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-1M 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING AND VERIFYING ITHEFLOCATION OF ALL233) UNDERGROUND .& LOCUS MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1 "=2000'f 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 88 PARCEL 236 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. SITE IS LOCATED WITHIN A ZONE it 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. SIYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 **RE —USE EXISTING 1000 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND APPROVED , MA DATE BOARD OF HEALTH Yarmouth Heatt';a Department fte .Date 421-1 TITLE 5 SITE PLAN OF #326 STATION AVENUE SOUTH YARMOUTH, MA PREPARED FOR FAITH KEHOE F CS Tcr`/�� SU; 3 DANIEL A. OJALA, P.E., P.L.S. DATE: OCTOBER 17, 2018 off 508-362-4541 I fax 508-362-9880 downcape.com 90WO cape en�ifieeria f, ific. civil engineers Ion d surveyors 939 Main Stree t ( R to 6A) YARMOUTHPORT MA 02675 18-368