HomeMy WebLinkAboutEngineered Plan - 20184 FI LL A LS 1OYR 3/2 B LS 1OYR 5/4 C MS 2.5Y 6/8 120" 25.7' NO GROUNDWATER ENCOUNTERED LICE # > 8-398 ELEV. 35.7' TOP ACCESS COVERS TO WITHIN 6" OF FIN. GRADE D. EL. 38.4' MINI IIU 79;' nF rnVFR MIM PRFrACT SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE PRECAST H-10 RISERS (TYP.) 34.7' INSTALL TEE 4" OSCH40 PVC PIPES LEVEL 1 ST 2' 10" EXISTING 14" TEE SEPTIC TANK** TEE *33.4'f :• 000000000000 GAS BAFFLE 32.56' 32.39' WATERTEST D'BOX FOR LEVELNESS 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) ( 12 q, SLOPE) FOUNDATION -EXISTING SEPTIC TANK 7' D' BOX *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE LEGEN D 99 - EXISTING CONTOUR X 99- 1 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH 1 TEST HOLE 2Y� SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: PHIL RENAUD DATE: 11 /7/ 18 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 0" 9„ 12" 28" 33.4' (1 % SLC - 4' Scale:1 "= 20' 0 10 20 30 40 50 FEET ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. 36 v - �36 PROVIDE INSPECTION PORTS TO / WITHIN 3" OF FINISH GRADE BOTTOM TH 1 EL. 25.7' NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALL33) AND VERIFYING IDITHE LOCATION OF ALL 2UNDERGROUND & LOCUS MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1 "=2000'f 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 99 PARCEL 86 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE X 12. EXISTING LEACHING FACILITY SHALL BE PUMPED (AREA OF MINIMAL FLOOD HAZARD) AS AND REMOVED. SHOWN ON COMMUNITY PANEL #25001 CO587J DATED 7/16/2014 A TWO BEDROOM DEED RESTRICTION IS REQUIRED SITE IS WITHIN A ZONE IL. SYSTEM DESIGN: 21.00' GARBAGE DISPOSER IS NOT ALLOWED 4.00'j EXISTING 2 BEDROOM DWELLING b DESIGN FLOW: 2 BEDROOMS 0 110 GPD = 220 GPD "' 00 USE A 220 GPD DESIGN FLOW 2.83' j Q �_ SEPTIC�TANK 2?0 rPD_-_(2)_-= 440 25.00' **RE -USE EXISTING 1000 GAL. SEPTIC TANK LEACHING: SAS DETAIL 4.73 SF/LF x 4' LENGTH = 18.92 SF PER QUICK4 SCALE: 1" = 10' PLUS STANDARD LP UNIT 220 GPD/0.74 GPD/SF = 297.3 SF LEACHING REQ'D 297.3 SF/18.92 SF/UNIT = 15.7 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (16) QUICK4 PLUS STANDARD -LB -UNITS IN FIELD CONFIGURATION AS SHOWN BEDROOM 16 UNITS x 18.92 SF/UNIT = 302.72 SF > 297.3 SF 297.3 SF (0.74) = 220 GPD (OK) DINING KITCHEN ROOM CI r1r1M E)1 A K1 NOT TO SCALE `16 DATE DANIEL A. OJALA, P.E., P.L.S. APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF , MA 86 ASTOR WAY SOUTH YARMOUTH, MA PREPARED FOR SHEILA S. DERN DATE: NOVEMBER 16, 2018 off 508-362-4541 I fox 508-362-9880 downcape.com dowa cave ell gineerin1, inc. civil engineers land surveyors 939 Main Street ( R to 6A) YARMOUTHPORT MA 02675 18-398 CCSEPTIC-DERN.DWG