HomeMy WebLinkAboutEngineered Plan - Rev. 2018ACCESS COVERS TO WITHIN 6" OF FIN. GRADE TOP FOUND. EL. 21.6' MINIMUM .75' OF COVER OVER PRFCAST SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE PRECAST H-10 RISERS (TYP.) 2 0 19'9INSTALL TEE 4" OSCH40 PVC o PIPES LEVEL 1ST 2' 10" EXISTING 1411 TEE SEPTIC TANK** TEE *18.6't GAS BAFFLE t_ 17.88' 17.71 ' �!• WATERTEST D'BOX FOR LEVELNESS 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) ( 9 % SLOPE) FOUNDATION -EXISTING SEPTIC TANK 8' D' BOX *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE LEGEN D 99 - EXISTING CONTOUR X 99• 1 EXIST. SPOT ELEV. -[991-- PROPOSED CONTOUR 19$•41 PROPOSED SPOT EL. TH1 TEST HOLE SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: PHIL RENAUD DATE: 1 1 /7/ 18 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS Q ELEV. 1. 011 20.5' � V G` \ GRAVEL DRIVE / OH w�RES FI LL 10" \ c A LS 'EXIS\TING15" 1OYR 4/2 DWE B LS 30" 1OYR 5/6 18' C PERC MS 2.5Y 7/4 120" I 110.5 NO GROUNDWATER ENCOUNTERED LICE # 13-397 (1 % SLOPE) 6' - ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORTS TO WITHIN 3" OF FINISH GRADE OVER SYSTEM • 17.0' QUICK4 PLUS STANDARD LOW PROFILE UNITS OVERALL DIMENSIONS TO CUTSIDE OF UNITS: 17.0'x11.33' (NO STON= PROPOSED) LEACHING FACILITY NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING Whites Path 3. MINIMUM PIPE PITCH TO BE 1 /8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST eac Locus UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. r wnin9 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) o z 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. sro�. o mall o at n 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. `1'n�j9� a 00 00� 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF �. oor eg nod HEALTH AND PERMISSION OBTAINED FROM BOARD a Hazelm OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING (1-888-344-7233) AND VERIFYING IGSAFE THE LOCATION OF ALL UNDERGROUND & LOCUS MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1 "=2000'f 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 99 PARCEL 86 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE X 12. EXISTING LEACHING FACILITY SHALL BE PUMPED (AREA OF MINIMAL FLOOD HAZARD) AS AND REMOVED. SHOWN ON COMMUNITY PANEL #25001 CO587J DATED 7/16/2014 A TWO BEDROOM DEED RESTRICTION IS REQUIRED VARIANCES REQUESTED: SYSTEM DESIGN. UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1a): REDUCTION IN SETBACK, SAS TO LOT LINE (10' TO 5') GARBAGE DISPOSER IS NOT ALLOWED (1b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 12.8' & 13.4') 6.5' BOTTOM TH 1 EL. 10.5, 'll c, O A 0 'v TH1 s�A BENCHMARK: CONC. STEP AT ELEV. 21.7' EXISTING GAS DWELLING MTR. TOF=21.6' 1� i sy 8S 20 Op, LOT 284 4,221 t SF100, O SAND_ J EXISTING, DWELLING • • 10 20 30 40 50 FEE I EXISTING 2 BEDROOM DWELLING DESIGN FLOW: 2 BEDROOMS ® 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 _.._ **RE -USE EXISTING 1000 GAL. SEPTIC -TANK =- LEACHING: 4.73 SF/LF x 4' LENGTH = 18.92 SF PER QUICK4 PLUS STANDARD LP UNIT LLIVINGFOOM BEDROOM 220 GPD/0.74 GPD/SF = 297.3 SF LEACHING REQ'D 297.3 SF/18.92 SF/UNIT = 15.7 UNITS KITCHEN 0 BEDROOM THEREFORE, USE GRAVELLESS SYSTEM OF (16) a QUICK4 PLUS STANDARD LP UNITS IN FIELD CONFIGURATION AS SHOWN 16 UNITS x 18.92 SF/UNIT = 302.72 SF > 297.3 SF 297.3 SF (0.74) = 220 GPD (OK) FLOOR PLAN NOT TO SCALE APPROVED DATE BOARD OF HEALTH Permit ,dlid for REPAIR t)1• F optic variances. TITLE 5 SITE PLAN ONLY,, due to State and Local septic v,tnanees: Board of Itealth review and approval is required for any future ' ad41 ions/re00% a+ions/alterations to OF sewage facilities and/or shructua cs/dwcdling. 5 FRANKLIN STREET SOUTH YARMOUTH, NIA Z2 Ley at^=e. Date k- `A-�� DATE DANIEL A. OJALA, P.E., P.L.S. PREPARED FOR MCKENZIE DATE: NOVEMBER 27, 2018 REV.: DECEMBER 4, 2018 (WATER MAINS) off 508-362-4541 I fax 508-362-9880 downcope.com opwo cape ell i4eerbi�, inc. civil engineers land surveyors 939 Main Street ( R to 6A) YARMOUTHPORT MA 02675 18-397 CCSEPTIC-MCKENZIE.DWG