Loading...
HomeMy WebLinkAboutEngineered Plans - 2018TBM-2 Cor./Bott. Step EL, =101. 94 i PB 220-PG 149 N 07'37'3.4" W 99.68 �, • S 7 --'+ x `w� / 100,06 LOT 21 (-9-,943-t- S. F / I x 100.21 99.84 1 x 1100.66 BH T' N QI / Q� 04 o 1 /EXISTING/ N 00 1 HOUSE(#50)/ 9b,78 T. 0. F.=102.2f xI x I, 100.59 / I EXISTING SEPTIC TANK I TOP OF TANK, EL.=99.53 99,97 TP INV.(OUT)=98.20t(VERIFY) PROPOSED S.A.S.- -10' EXISTING LEACH TRENCH TO gE REMOVED (SEE NOTE 11) 99.83 + 100.54 x 100,16 SPIKE PAT/0 100,89 ® GEN. m AC _4-o0� �- a 99,92 EDGE OF PAVEMENT 9 9.9 5 COLBURNE PLAN REFERENCE: CERTIFIED PLOT PLAN' BY LOW & WELLER, INC., YARMOUTH, MA DATED 10/30/84 Permif valid for REPAIR ()F SEPTIC SYS'fEM ONLti :,. duc to State and I ."cal septic variances. Board of Ileafth review and approval is required' for any C titre additions/ren+,satiou+/alterations to sewage facilities and/or structu,, esidwetling. Yarmouth Health Pepattn►ent AIPP()�'1� DI RC 4 n�100.04 0 \ Na �`99.01 100,57 ,00�A x 0 UJ 99.35 O N� III,o N +100,49 o r Q x 100,7 00 00 z � o W w + 100.64 ,1 x 101,28 0 99,82 101.19 • I • I x 100,54, + 100,73 100.33 00,90 05 100,19 99,96 -LP.ATH .23 99.83 J 99,781 e AG, NAIL 99,77 TOM-1 MAG. NAIL SET EL. = 99.77 Date q W N* OF MgsS. o PETER T. McENTEE � CIVIL 35109 W3cst(�- OWNER OF RECORD ROBILLARD, BERNICE TR THE AGN!ES A EGAN IRREV TRUST 10 BROOKMEADE CT STERLING, VA 20165 LEGEND _�dq, old Town House R - - gg -- EXISTING CONTOUR Ivanhoex ioo:98 EXISTING SPOT GRADE -W EXISTING WATER SERVICE N• // -G - EXISTING GAS SERVICE o Ave OVERHEAD WIRES CDo Cn5 tonce TEST PIT � Cardinal Ln 0 or ^ BENCHMARK � Buntin Ln j Q fl 1 Mockingbird I Ln LOCUS LOCUS MAP GENERAL NOTES: NOT TO SCALE 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: -310 CMR 15.405(1)(b): 1) A 3' variance, S.A.S. to cellar wall, for a 17' setback. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5, ALL ELEVATIONS BASED ON AN ASSIGNED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8, THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN MAP ID: 76-68 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 50 COLBURNE PATH, WEST YARMOUTH, MA Prepared for: D.A. Brown, Inc., P.O. Box 145, Centerville, MA 02632 Engineering by: SCALE DRAWN JOB. NO. Engineering Works, Inc. 1 "=20' P.T.M. 279-18 12 West Crossfield Road, Foeestdole, MA 02644 DATE CHECKED SHEET NO. (508) 477-5313 11/30/18 P.T.M. 1 Of 2 PROPOSED SEPTIC TANK PROVIDE RISER WITH FRAME & COVER OVER INLET & OUTLET MANHOLES AND SET OUTLET RISER TO FINISH GRADE. OUTLET COVER SHALL BE SECURED TO PREVENT UNAUTHORIZED ACCESS. T.O. F=102.2 t -F.G. EL.=101.0f F.G. EL.=100.7f I 1 14 EXISTING 48" LIQUID LEVEL ADD GAS I BAFFLE NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPES & INVERTS EXITING HOUSE, PRIOR TO INSTALLATION. 2) D-BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 4) A GAS BAFFLE SHALL BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. DESIGN CRITERIA NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL.98.0 FOR A DISTANCE OF 15' AROUND THE PROPOSED D-BOX PERIMETER OF THE S.A.S. INSTALL RISER & COVER PROPOSED S.A.S. SET TO 6" OF GRADE INSTALL RISER & COVER OVER ONE CHAMBER AND SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT F.G. EL.=100.5f F.G. EL.=100.5t MAINTAIN 2% SLOPE OVER S.A.S. L= 7' ® S=1% (MIN.) 4"SCH40 PVC INV.=97.83 J PROPOSED INV.=98.20 D BOX (VERIFY) 3 OUTLETS H-10 L = 16'(MAX.) S=1% (MIN.) 4"SCH40 PVC -2- LAYER OF 1 /8" TO 1 /2" DOUBLE WASHED STONE (OR APPROVED FILTER FABRIC) —3/4" TO 1-1/2" DOUBLE 2.6 4.8' 2.6' WASHED STONE INV.=97.66 EFFECTIVE WIDTH = 1,0' INV.=97.50 2-500 GALLON LEACHING CHAMBERS WITH STONE AROUND AND BETWEEN CHAMBERS AS SHOWN r H-10 RATED 2' EFF. DEPTH TOP CONC. ELEV.= 98.3t BREAKOUT ELEV.= 98.00 INV. ELEV.= 97.50 BOTTOM ELEV.= 95.50- 4' OF NATURALLY OCCURRING PERVIOUS MATERIAL 5' ABOVE GROUNDWATER NO GROUNDWATER, EL.=88.8 - 4 SEPTIC SYSTEM PROFILE NUMBER OF BEDROOMS: 3 BEDROOMS SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 GPD DESIGN FLOW: 330 GPD GARBAGE GRINDER: NO -not allowed with design LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF .i1+ �-,ru/3r EXISTING SEPTIC TANK: 1000 GALLON CAPACITY PROPOSED D-BOX: 1 INLET, 3 OUTLET (MIN.), H-10 RATED USE 2-500 GALLON LEACHING CHAMBERS IN SERIES WITH STONE AROUND AND BETWEEN CHAMBERS (10' x 29.0') SIDEWALL AREA: 2(10.0' + 29.0') X 2 = 156.0 SF BOTTOM AREA: 10.0' x 29.0' = 290.0 SF TOTAL AREA: ....................................... ...................... 446.0 SF DESIGN FLOW PROVIDED: 0.74 GPD/SF(446.0 SF) = 330.0 GPD 8.5' 4' EFFECTIVE LENGTH = 29.0' LEACHING SYSTEM SECTION I 3/4" TO 1-1/2" DOUBLE WASHED STONE 3" LAYER OF 1/8" TO 1/2" DOUBLE WASHED STONE (OR APPROVED FILTER FABRIC) i SOIL LOG DATE: NOVEMBER 29, 2018 SOIL EVALUATOR: PETER McENTEE PE(SE#1542) WITNESS: AMY VON HONE IRS HEALTH AGENT ELEV. TP DEPTH 100.5 0 FILL 100.0 A1 6" LOAMY SAND 99 5 10YR 4/2 B 12" LOAMY SAND 10YR 5/8 98.0 3P C ERC 30"/48" COARSE SAND 10YR 6/4 88.8 1 128" PERC RATE <2 MIN/IN. "C" HORIZON NO GROUNDWATER ENCOUNTERED SEPTIC LAYOUT BEDROOM ffDROOM HALL BEDROOM BATH PATIO H ENTRY DN KIT./DIN. ENTRY j GARAGE LIVING ROOM ENTRY FLOOR PLAN PROPOSED SEPTIC SYSTEM UPGRADE PLAN 50 COLBURNE PATH, WEST YARMOUTH, MA Prepared for: D.A. Brown, Inc., P.O. Box 145, Centerville, MA 02632 Engineering by: SCALE DRAWN JOB. NO. Engineering Works, Inc. N.T.S. P.T.M. 279-18 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO. (508) 477-5313 11/30/18 P.T.M. 2 Of 2