Loading...
HomeMy WebLinkAboutEngineered Plans - 2018Z Ql 99.46 99.82 --97— —EXISTING CONTOUR x 100.98 EXISTING SPOT GRADE 97 PROPOSED CONTOUR IIV EXISTING WATER SERVICE G EXISTING GAS SERVICE —B.H. W.-- OVERHEAD WIRES TEST PIT �} BENCHMARK LEGEND E ROMP 6A NOT TO SCALE C'Ue 100.41 o f CB 1 \- pavement 101.03 R=160T,--------- 1-02------- _ 101a2 / 101,4s- HYD, •�102.43`------ _r—-------—1-e6------ _�' — LIJ Irea--------------'rOS N o f/6 I -11p---------------11 O % / -- r - - _ - - - - - 1 Iz' -- Z Fyn 108.84 110--- / 11348 A`A_ EXISTING CESSPOOLS / / `� _ �r alc01_����'� CONTRACTOR SHALL PUMP,�'_--- FILL W/SAND & ABANDON, x1s.o2-t1r� + .. . +• _ 2a + 36 OR REMOVE. f / ,r—.. VENT _ TANK 120,96 } _ / r _ g _ ?_- / r �._— _ 1 RE VE f ° — BENCHMARK x 117.62 :,:...";" `� �� i`� ;=71 ° � 5 ; ---- ORANGE PAINT ON _ A _ —J X_i2a.25` _8 _ TOP OF STEPS / t 11 �': 12{_n J �x 12z. s_� -- — — — �` - — — — — 12 .66 6 EL.=127.37 i / I 126.79 124.95 BM 127.98 CB X 1!�412 _ - N 127.37 0-- - - - 113.95 / ,/ // // .12248 C�- /1V - 7.88 j r',/ / 127.01 126.64 127.92 ; ,, / ? I ! , 26.zz`'. ; ` ' : EXISTING ! ! `11 C x LLJ_ HOUSE(IJ09)f - UJ •r �' x, , ^ _ ... 129.01 N 4 i I I DRIVEWAY i PORCH / r ' N O`n C d I Z N a O 129.02 PATIO x x Z Z I I I I r r 2r 1.76 131.35 131.45 12 7:19 GARAGE 102,26 101.92 c3�o W o I `----------12-8—'��' I I W -Permit,A t l2EPA1 -St OF Sh:l''1"I(' Sl'�i1't:M Localfor v lriances. cV M �.-��2--- ONLY.; due o rte ar► I ucal septic Board of ilea th review a rI :+pProval is required for o o 0 � � _--- MAPID: 123-16 - --� - -- �� _ [i�ture additions/ sewage faclfif ies'ant/m-s enoN alionslalleration:s to uclu,es/dwelling. Z 46,989 ±SF(CALC)�' -, `- '----_--- —128 _.___ l'a rmoutk► H Ifft f>cpattenrnt -- A :Y OV 175.69- �f S 8432'50" E ' __ 118 ---- __ _ n OF Mgss9�yG _ ----- o PETER T. McENTEE U CIVIL No. 35109 tt Mke Engineering by: Survey by: Engineering Works, Inc. JCEngineering, Inc. 12 West Crossfield Road 2854 Cranberry Hwy. Forestdole, MA 02644 E.Warehom, MA 02538 (508) 477-5313 (508) 273-0377 JOHN L. WILL 1i �� Date OWNER OF RECORD �O CONSTITUTION PROPERTIES, LLC 967 NORTH MAIN STREET /I f Z71J9 RANDOLPH, MA 02368 SCALE DRAWN JOB. NO PROPOSED SEPTIC SYSTEM UPGRADE PLAN 1 "=30' P.T.M. 271-18 DATE CHECKED SHEET NO. 309 ROUTE 6A, YARMOUTH PORT, MA 11/15/18 P.T.M. 1 Of 2 Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:118.0 SEPTIC TANK FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. INSTALL RISERS & COVERS OVER INLET AND SET TO 6" OF FINISH GRADE. PROPOSED D-BOX PROPOSED S.A.S. PROVIDE TWO ACCESS MANHOLES TO WITHIN 3" CELLAR FLOOR=124.7t INSTALL WATERTIGHT RISER & OF FINISH GRADE FOR INSPECTION PURPOSES T.O.F.=132.0t COVER SET TO 6" OF GRADE F.G. EL.=128.0t F.G. EL.=123.0t F.G. EL.=122.0E F.G. EL.=120.5 to VENT 123.5E ADD CLEANOUT MAINTAIN 2% GRADE (MIN.) OVER S.A.S. 5' L=24' L714:714'�S�CH ® S=1% (MIN.) ®S=% (MIN.) 4"SCH40 PVC 4"SC40 PVC 6" " 10"I as as 14" 99®m6aa®INV.=120.00 48" LIQUID aEL 4' 4.8'4' GAS �FLE INV.=.PROPOSED INV.=118.70 INV.=119.75 D-BOX EFFECTIVE WIDTH = 12.8' INV.=117.50 2-500 GALLON LEACHING CHAMBERS PROPOSED SEPTIC TANK SURROUNDED WITH STONE AS SHOWN CONTRACTOR SHALL LOCATE AND VERIFY H-20 RATED ALL SEWER OUTLETS PRIOR TO INSTALLATION. ESTIMATED SEWER INV.=123.0t TOP CONC. ELEV.=118.1 f BREAKOUT ELEV.=118.00 NOTES: INV. ELEV.=117.50 t6306:3903Wmamma 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE BOTTOM ELEV.=1 15.00 aaaaff INVERTS, PRIOR TO INSTALLATION. 4' 2 X 8.5'=17.0' 2) SEPTIC TANK & D-BOX SHALL BE SET LEVEL AND TRUE 4' MIN. OF NATURALLY OCCURRING EFFECTIVE LENGTH = 25.0' PERVIOUS MATERIAL TO GRADE ON A MECHANICALLY COMPACTED 6" CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). 5' MIN. ABOVE GROUNDWATER LEACHING SYSTEM SECTION 3) INSTALL INLET & OUTLET TEES AS REQUIRED. BOTT. OF TP, EL.=110.5 - 4) CONTRACTOR SHALL INSTALL A GAS BAFFLE ON THE 3/4" TO 1-1/2" DOUBLE I WASHED STONE OUTLET TEE. 3" LAYER OF 1/8" TO 1/2" WASHED STONE SEPTIC SYSTEM PROFILE (DOUBLE OR APPROVED FILTER FABRIC) SOIL LOG BEDROOM ENTRY BEDROOM ENTRY DATE: NOVEMBER 1, 2015 -ENTRY NTRY SOIL EVALUATOR: PETER McENTEE PE(SE#1542) KITCHEN BATH _j 6DN WITNESS: PHIL RENAUD R.S. HEALTH AGENT VING =ROOM ELEV. TP-1 DEPTH BATH = DN NEW 122.0 0 LIVING ROOM_ BATH r-- SANDY LOAM 10YR 4/2 DINING DINING NEW I ROOM KITCHENI 121.5 6„ B ROOM BEDROOM BEDROOM SANDY LOAM 10YR 5/6 119.3 32" C1 FOR ILLUSTRATION PURPOSES ONLY FINE SAND 10YR 6/4 PERC 40"/58" EXISTING FLOOR PLAN PROPOSED FLOOR PLAN 117.0 60" C2 GENERAL NOTES: MED. SAND 2.5Y 7/3 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL 138" BOARD OF HEALTH AND THE DESIGN ENGINEER. 110.5 NO GROUNDWATER ENCOUNTERED 2• ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE PERC RATE: < 2 MIN./INCH ("C" HORIZONS) LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: -310 CMR 15.405(1)(b): 1) A 3' variance to the 3' maximum cover requirement, for up to 6' of max. cover. S.A.S. shall be H-20 and vented. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN CRITERIA DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING NUMBER OF BEDROOMS: 2 + 1 PROPOSED = 3 FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN SOIL TEXTURAL CLASS: CLASS I ENGINEER BEFORE CONSTRUCTION CONTINUES. DESIGN PERCOLATION RATE: <2 MIN/IN 5. ALL ELEVATIONS BASED ON an ASSUMED DATUM. (0.74 GPD/SF LOADING RATE) 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF DAILY FLOW: 330 GPD HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. DESIGN FLOW: 330 GPD 7. WATER SUPPLIED BY TOWN WATER SERVICE. GARBAGE GRINDER: NO 8• THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS .74 GPD/SF AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY DIRECTED BY THE APPROVING AUTHORITIES. PROPOSED DISTRIBUTION BOX: 1 INLET, 3 OUTLETS 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY USE 2-500 GALLON LEACHING CHAMBERS IN SERIES THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES SIDEWALL AREA: 2(12.8' + 25.0') X 2 = 151.2 S.F. IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND 12.8' x 25.0' = 320.0 S.F. REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). BOTTOM AREA: 12, AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE TOTAL AREA: .............................................................. 471.2 S.F. INSPECTED BY A LICENSED SOIL EVALUATOR PRIOR TO BACKFILL. 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.7 GPD IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. Engineering by: Survey by: SCALE DRAWN JOB. NO. PROPOSED SEPTIC SYSTEM UPGRADE PLAN Engineering Works, Inc. Road JCEngineering, Inc. 2854 Cranberry Hwy. N.T.S. P.T.M. 271-18 309 ROUTE 6A, YARMOUTH PORT, MA DATE CHECKED SHEET NO. 12 West Crossfield Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 Forestdole, MA 02644 (508) 477-5313 E.Wareham, MA 02538 (508) 273-0377 1 1 /15/18 P.T.M. 2 Of 2