Loading...
HomeMy WebLinkAboutEngineered Plan - 2000BgNCI MARK TOR OF FOUND TION 20 FT. MINIMUM FROM CELLAR ELEY.�� 10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB OR CRAWL SPACE (ASSUMED) COVERS 4• SCHEDULE 40 PVC PIPE �U MIN. PITCH 1/8• PER FT. 40. CAST IRON PIPE 0\lA ` (OR EQUAL MINIMUM PITCH 1 /4 PER FT. �, q 1� 2 FLOW LINE S 10• ELEV � - -MIN. V =, "t' •1 % LEVEL �1�1 �'� J • r ai ELEV. BAFFLE aARELEV. _ 1 6 ELEV. _ 0, DISTRIBUTION ;n BOX o'• --/ (TO BE PLACED ON FIRM BASE) TO BE WATER TESTED 1500 GALLON IF MORE THAN ONE OUTLET SEPTIC TANK (TO BE PLACED ON FIRM BASE) 3/4• TO 1 1/2•J WASHED STONE SEWAGE DISPOSAL SYSTEM PROFILE NOT TO SCALE -�� Rv 16 CLEAN SAND LOAM AND SEED 2• LAYER OF 1/8• TO 1/2• WASHED STONE VFNT REQUIRED Z 1 CU. FT. OF CONCRETE ANCHOR 0. ° ° ELEV. G� HIGH CAPACITY INFILTRATORS WTH STONE IN AN z �jbX 11'14.` %J TRENCH FORMATION SOIL ABSORPTION �� z"�—— SYSTEM (SAS) INDEX ADJUST USGS PROBABLE WATER TABLE ELEV. = %,,J OBSERVED WATER TABLE ( / / ) ELEV. = NIA` BOTTOM OF TEST HOLE ELEV. = 80.9 ;�q lonzwo LEGEND: EXISTING SPOT ELEVATION 00,,0 EXISTING CONTOUR----00----. FINAL SPOT ELEVATION FINAL CONTOUR SOIL TEST LOCATION UTILITY POLE -O- TOk% WATER —W VY� CATCH BASIN (®� GAS LINE BOG CLEAN OUT CESSPOOL C.P.0 EHEAL71' dD 5 2090 ue ' T. DEPTH I HORIZ TEXTURE COLOR MOTT. I OTHER � r,LL S � � Lora, y, 10y 2 212 po-� WATER ENCOUNTERED AT . ELEV. _ g� DESIGN CALCULATIONS NUMBER OF BEDROOMS GARBAGE DISPOSAL UNIT No TOTAL ESTIMATED FLOW ( 110 : GAL/BR./DAY X BR.) 330 GAL/DAY REQUIRED SEPTIC TANK CAPACITY 1:0 GAL ACTUAL SIZE OF SEPTIC TANK 1500, SOIL CLASSIFICATION I DESIGN PERCOLATION RATE < 5 MIN./IN. EFFLUENT LOADING RATE 0.74 GAL/DAY/S.F. LEACHING AREA 4_-?SQ. FT. /;X3;,).t(47AzXicy— r" LEACHING CAPACITY (AREA X RATE) '�GAL./DAY RESERVE LEACHING CAPACITY GAL/DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALSSHALLONFORM TO D.E.P. TITLE 5 AND THE TOWN OF _�RULES AND REGULATIONS FOR THE SUBSU FACE DISPOSAL OF SEWAGE 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6' OF FINISHED GRADE 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED 1N PLACE. . 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH__ Dce_MIM-OP ZW,.!,,ik; i ZGULAiiONS:_ +DN+'NER j APPUCA..NT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE. AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY. EXCAVATION CONTRACTOR IS TO CALL 'DIG -SAFE' AT 1-688-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY, a PARCEL IS IN FLOOD ZONE 9. LOT IS SHOWN ON ASSESSORS MAP Prti I AS PARCEL 10. E)OSTING SEPTICS ARE TO BE PUIVPED AND BACKFUlf - "Crm6- cD � � C.. �PQ-�'1 - Ci►J� � �` �{� � f`�';`� / '•' rP yr .-fly ";.;+"-f "+�' __.� . "? la'_. . 12• APPROVED: BOARD OF HEALTH DATE AGENT PROPOSED SEPTIC DESIGN FOR -APWoCTH PROJECT LOCATION TADCO ' ENVIRONMENTAL CONSULTANTS 26' COMPASS LN. DY NIS, MA. 02638 385-24 DATE` { SCALE N = ZOO JOB NO. REVISED LOCATION MAP REVISED SHEET I OF J__j 1998 T.