HomeMy WebLinkAboutAir Curtains Information SheetFEATURES OF HEATED AND UNHEATED MARS AIR DOOR° NATIONAL SANITATION FOUNDATION 3Y INSTALLAI AS LISTED IN STANDARD 37 Mars Air Door® need only be bolted to wall with three fasteners and Models number 38 NCH for customer entrance doorways and NHV 48 for service entrance doorways. SOUND LEVEL The Mars Air Doors operates at a very low sound level to prevent disturbing personnel and customers in the immediate vicinity. Meet OSHA standards. '�LOCITY CONTROL FOR VARIABLE AIR SPEED Adjustable louver damper controls are provided for regulating rate of air flow. This added feature is a means of setting air velocity to desired individual preference. Velocity control can reduce air ve- locity up to 60% with louvers in totally closed position. .IR DIREC' ONTROLS Adjustable vanes at outlet nozzle can be positioned to direct air where needed and readily set to compensate for possible draft conditions through door openings. 40' girth sweep front to back 'TRIC MO The continuous duty type motor is engineered to provide many years of maintenance free service. It contains lifetime lubricated sealed ball bearings, totally enclosed motor, is resilient mounted and protected by an automatic thermal overload switch. U.L. and Los Angeles approved. 1750 R.P.M. 115V. or 230V. 1Ph. Explosion proof motors available. Two speed motors available. FIRE RETARDANT AND CORROSION PROOF Mars Air Door cabinets are manufactured of one piece molded high density polycarbonate. They have self -extinguishing char- acteristics, are resistant to high heat and all chemical and weather exposures. ELECTRIC WIRING Conduit box is supplied with 1/2" conduit fitting, Location of conduit box can be on either side or at top of air curtain cabinet. MARS SERVICE WINDOW AIR CURTAINS MODEL NUMBER W-25 • FAST FOOD SERVICE Provide complete protection against insects, dust, dirt and fumes. This invisible air barrier affords both the customer and attendant an unobstruct- ed view while at the same time offering clean, sanitary conditions. Beautifully designed high impact polycarbonate exterior cabinet for complete protection in any kind of weather. Maximum distance from air outlet to counter — 5 feet. SPECIFICATIONS FOR ARCHITECTS AND SANITARIANS The air velocity of air doors designed for use over windows should be no less than 600 feet per minute (FPM), across the entire window as measured two feet above the counter. Air intake shall be provided with a washable air filter screen. Air outlet shall have an opening of at least 8 inches deep. All interior and exterior parts shall be corrosion resistant to chemical and weather exposures. i 8-112" DEPTH 25" LENGTH ♦ Unheated 10" Height Heated 17" 11II�+lid HEATED or UNHEATED Mars Air Doors may be mounted with equal efficiency on inside or outside of window opening . Inside installation recommended for heated units. MODEL NUMBER W-25 SERVICE WINDOW com­stw. Single Phase Dowse wet F_.D ubie 50/60 Hz Service Service Choice of shai Motor Window Window FPM 1"0 D Widths Heights 9 Shipping P9 115V or 208/220' nwl .1 me 23o/2a0 Up To Up To Weight Unheated 1 amp % amp 30 inches 5 feet 20 Ibs 'Heated mot sued. 17 amp 30 inches 5 feet 23lbs For wider pass through openings, customer entrance C models may be used. (See page 2) 'Heated Unit: 3600 Watts 12,283 B.T.U.'s Hr. Heating unit doubly protected by fuse and automatic thermal overload switch. Heated units only available in 208/240 Volt Single Phase. Noise level: Measured indoors ELECTRIC WIRING Decibles: 63 "A" scale 3 feet from Unit. Unheated units supplied with On/Of cord and electrical plug. Heated units MARS N supplied with condulet box and On/Off/Heat control switch. 1 FOR WIDER OPENINGS Models No. W-25 or the C Models described on pg. 2 can be mounted side 14716 SOUTH BROADWAY, GARDENA, CA. 90248 by side to form a wider stream of air. Each unit is self contained and may be PHONE: AREA CODE (213) 770-1-%5 rearranged to suit changing needs at any time. Copyright © 1989 by Mars Sales Co., Inc. FAX (213) 324-3030 Toll Free Phone No. 1-800-421-1266 OTHER MARS AIR DOOR MODELS ... INDUSTRIAL TYPE WITH STEEL HOUSINGS Except California Bulletin No. C-291 PRINTED IN U.S.A. COMPLETE WITH AIR FILTER SCREEN Supplied with /T Mounting Brackets 5" LLL Intake Air Filter Screen Can be mounted over Sliding Window or Screen Air Outlet Nozzle 9 ® COMMERCIAL TYPE AIR CURTAINS HEATED and UNHEATED AilH 000 ® With Polycarbonate Cabinets C MODELS - CH MODELS Climate Control Insect UL Listed and Los Angeles Electrical Laboratory Listed National Electrical Code Compliance 1%4i IWO C" CERTIFIED CERTIFIED 38 NCH • NHV 48 ADVANTAGES • Keep insects, dust, dirt and fumes out. • For use over freezer and cooler doors to reduce humidity and prevent loss of cold air. • Doors may be left open eliminating the nuisance of opening and closing automatic and manual doors. • Reduce air conditioning costs. • Open doors conducive to attracting customers. • Less risk of accidents yet speeds up customer or personnel traffic. • Keep premises clean and sanitary. SAVE ENERGY REDUCE HEATING COSTS Recirculate trapped warm air to floor level for maximum savings. • Immediate Delivery 70", - T�w IWO "*`. S° ENTRANCE DOOR (C MODELS) RECEIVING DOOR (CH MODELS) USDA & FDA COMPLIANCE UL LISTED • LOS ANGELES LISTED HIGHEST QUALITY MOST EFFECTIVE ° 1989 MARS SALES CO. INC E w�_ - - - _ — C JI COLD STORAGE DOOR (CH MODELS) DISTRIBUTOR 11fil;'UNHEATED i. 1r 1 1.1 r " r A r' t C C MODELS UNHEATED MARS AIR DOORS' C MODELS ARE DESIGNED TO MOUNT OVER CUSTOMER ENTRANCES. They create a curtain of living air undetected by customers walking through doorway. Continually act as a barrier against outside air and maintain interior conditioned temperature. HOUSING DIMENSIONS: Height 143/4" Depth 123/4" hAnrial Nltmhar nacinnateG LENGTH of unit C MODEL NO. 1750 RPM MOTOR H.P. AMPS MAX. FPM AT NOZZLE MAX. CFM AT NOZZLE Wgt. Lbs. Phase —Single 115 v 230 V 36C 1/2 3.0 1.5 2275 1700 63 38C 1/2 3.0 1.5 2150 1700 64 42C 1 1/2 3.0 1.5 1950 1700 65 48C 1/2 3.0 1.5 1700 1700 67 60C 1/2 4.3 2.15 2040 2550 75 72C Two 1/2 6.0 3.0 2275 3400 120 Sound Level 64 Decibels "A" Scale Measured indoors 5 It. from nozzle, 2 motors tir dts. CUSTOMER ENTRANCE DOORA C Models —Unheated Air Curtains Purpose: PREVENT LOSS OF AIR CONDITIONING, BARRIER TO DUST RECEIVING/SERVICE DOORS CH Models —Unheated Air Curtains Purpose: ABOVE NORMAL INSECT CONDITIONS BARRIER TO DUST Door Widths Up To Heights Use Model Up To Number Door Widths U To Heights Use Model Up To Number 3 It. 10 ft. 36C 3 ft. 7 ft. 36CH 31/2 ft. 10 ft. 42C 31/2 ft. 7 ft. 42CH 4 ft. 10 ft. 48C 4 ft. 7 ft. 48CH 5 ft. 7 ft. 60C 5 ft. 7 ft. 60CH 6 ft. 10 ft. 72C 6 ft. 7 ft. 72CH 7 ft. 10 ft. Two-42C 7 ft. 7 ft. Two-42CH 10 ft. 8 ft. Two-60C 8 ft. 7 ft. Two-48CH 12 ft. 10 ft. Two-72C 10 ft. 7 ft. Two-60CH 15 ft. 8 ft. Three 60C 4 ft. 10 ft. 42CHS 2 CH MODELS UNHEATED RECOMMENDED FOR ABOVE NORMAL INSECT CONDI- TIONS. Receiving and service entrance doors —markets — restaurants —hospitals —food processing plants, etc. Inside or outside installation equally effective. Characteristics: Produce greater velocity of air with slightly higher sound level as compared to C Models. HOUSING DIMENSIONS: Height 143/4" Depth 123/4" 1 Initc with 1 H P mntnr- Height 181/2" DeDth 15" CH MODEL NO. 1750 RPM MOTOR H.P. AMPS MAX. FPM AT NOZZLE MAX. CFM AT NOZZLE Wgt. Lbs. Single Phase 115 v 230 V 36CH 1/2 4.3 2.15 3400 2550 63 38CH 1/2 4.3 2.15 3225 2550 64 42CH 1/2 4.3 2.15 2925 2550 65 48CH 1 1/2 1 4.3 2.15 2550 2550 67 60CH 1 13.0 6.5 3200 4000 110 42CHS 1 13.0 6.5 4600 4000 95 72CH Two 1/2 8.6 4.3 3400 5100 120 Sound Level: 70 Decibels "A" Scale Measured Indoors b n. Trom nozzle. 60 CH (1HP) 74 Decibels "A" Scale. Measured indoors 5 ft. from nozzle, 2 motors Purpose: PREVENT LOSS OF REFRIGERATED AIR, REDUCE HUMIDITY AND ICE BUILD UP COOLERS:For temperatures of +350 to +60°F. FREEZERS:For temperatures of -20° to +30°F. Door Widths U To 'Heights U To Use Model Number Door Widths U To Heights U To Use Model Number 3 ft. 8 ft. 36C 3 ft. 10 ft. 36CH 31/2 ft. 8 ft. 42C 31/2 ft. 10 It. 42CH 4 ft. 8 ft. 48C 4 ft. 10 ft. 48CH 5 ft. 8 ft. 60C 5 ft. 10 ft. 60CH 6 ft. 8 It. 72C 6 ft. 10 ft. 72CH 7 ft. 8 ft. Two-42C 7 ft. 10 ft. Two-42CH 8 ft. 8 ft. Two-48C 8 ft. 10 ft. Two-48CH 10 ft. 8 ft. Two-60C i 10 ft. 10 ft. I Two-60CH ELECTRIC HEATED AIR CURTAINS U.L. LISTED FOR USE OVER ENTRANCE DOORS IN FOR USE IN ALL SEASONS Shopping Plazas Supermarkets Restaurants 1 WITH HEATER FAN ON Department Stores Drug Stores Office Buildings over entrance doors as protection against cold wintry Hospitals and Convalescent Homes Hotels Motor Inns drafts entering indoor heated areas. Contributes warmth Quality Assurance Design and Construction to existing heating systems. Architects and engineers are justifiably concerned about the products they specify. The prod- 2 WITH FAN ON ONLY ucts must be reliable, economical, efficient and last for a considerable length of time. That iswhythe architect orengineer who isfamiliar with air curtains will pick aMars Air Door over in warm weather to prevent loss of air conditioning and all others. provide an effective barrier against insects and dust. Outside Cold Weather Electric Heater On Ambient Air Input Outside Warm Weather Fan Only Proper Mounting on Interior Wall or Transom Indoor installation suggested. INTERIOR EXTERIOR rLECTRICAL FEATURES Heat/Off/Fan Only with manual selection at wall mounted so 60 70 80 96 thermostat�� Ready to wire mounted control panel Heater will not function with fan in OFF position Excess Temperature Cut Out in heater with Automatic Reset Switch and Fuse Supplied with 24 Volt Remote Control Thermostat Continuous heavy duty motor totally enclosed 1/2 H.P. motor protected by Automatic Thermal Overload Switch and Fuse 5,s FM Two speed motors available WINDOW L = �—(2) TRANSOM INSTALLATION • (1) Three predrilled holes for easy mounting. ` ` \ (2) Attach cabinet assembly to solid aluminum brace Fb 1 bars. Approximate size 11/y/'. x 11Y thick. Choice of ' I I vertical or horizontal installation determined by size °i and shape of transom. (3) Power source connected to control box. Right hand side. Left hand side by request. ?) NOTE: Power may be connected from existing air (DOOR OPconditioning electrical control panel. ENING) Always specify wattage, voltage and phase when ordering Other voltages available. ENERGY TABLE SINGLE PHASE UNITS 6000 Watts 9000 Watts 12000 Watts Volts BTU/HR 20,500 BTU/HR30,700 BTU/HR 41,000 208 30 Amps 45 Amps 60 Amps 240 25 Amps 38 Amps 50 Amps THREE PHASE UNITS Volts 8000 Watts BTU/HR 27,300 12000 Watts BTU/HR41,000 16000 Watts BTU/HR 54,600 208 24 Amps 35 Amps 46 Amps 240 21 Amps 31 Amps 41 Amps 480 10 Amps 15 Amps 20 Amps For 72C Units figure double on Watts and Amps VARIABLE AIR SPEED Adjustable Louvers •Model Number Designates For Velocity Control. Length of Unit in Inches � Add 3" I T(Heater Control Box) 151/2 {.--.{II3'/a" I.If D. OPTIONAL: Micro Switch for automatic on/off control. When door is opened. I 3'/e" O.D. Mars Air Door will start automatically and stop when closed. I Polycarbonate I Control Box DECORATIVE COLORS: Gold, Grey, Beige, or dark Bronze on request. White is regular C binet production color. All Mars Doors have one second motor start to full capacity operation. For unusual or problem door opening consult factory representative for suggestions regarding most practical and efficient type of installation. 'For higher cooler doors use the CH Models. TWO SPEED 1/2 H.P. MOTOR AT NO ADDITIONAL CHARGE. AVAILABLE UPON REQUEST. 4 a Air Directional Heat/Off/Fan Only Steel Heavy Duty Control Vanes Temperature Selector Switch Cadmium Plated placed on right hand side. Squirrel Cage Fans. Heating Elements. Left hand side on request. For performance specifications refer to C Models chart. Page 2 Heated Models are 14 pounds heavier than Unheated C Models. Model Number Designates Length of Housing. Add 3" on side for control box. SELECTION CHARTS Door Widths Door Heights Use *Model Up To Up To Number 3 ft. 2 in. 8 ft. Heated 38C 31/2 ft. 8 ft. Heated 42C 4 ft. 8 ft. Heated 48C 5 ft. 8 ft. Heated 60C 6 ft. 8 ft. Heated 72C 7 ft. 8 ft. Two Heated 42C's 8 ft. 8 ft. Two Heated 48C'S 10 ft. 8 ft. Two Heated 60C's 12 ft. 8 ft. Two Heated 72C's NOTE: For higher door openings use heated 42CHS or 60CH units (10 to 12 ft.). Which contain 1 HP motors. Characteristics: 1) Has higher noise level. 2) Use higher watts per energy table. w HEATED UNIT NOTE: For wider doorways, units can be mounted in multiple and arranged for single thermostat control. Consult factory.