2009 - Email, Faxes, Info Re: Pools
Jim The Health code requires the bottom of the pool fence to be firmly secured at ground (section 105 CMR 435.03) He will need to address this issue before using the pool. Bruce From: Brandolini, Jim Sent: Friday, May 01, 2009 4:32 PM To: Murphy, Bruce Subject: Hampton Inn Exterior Pool Fence Bruce: Based on my observation of the pool fence enclosure this day the bottom rail on the northwest side exceed four (4) inches above grade. Section 421.9.2—(public and semi public pools) provides that "Enclosure fences shall be constructed so as to prohibit the passage of a sphere larger than four inches in diameter through any opening or under the fences." The 2 inch provision if for Private pools. I will be requiring that any area where the bottom fence rail is greater than four inches above grade be reduced. Jim R'pr 24 2009 7:42RM RQURTIC DESIGN 16625600744 p.l w9w (a " t-,09;;6 3227Jean Dr F;R0V1M© MeoWhis, Tu 38118 APR 2, d 2009 901-79S-34S7 email aquat%destgn44r 1iughes met HEALTH DEFT. To: Board of gealfk From: Jews Al Garner Attu: Bruce Muryby 4/23IV9 Wke Location Fax Nainber SM-760-3472 Phone Number :901-795-3137 or 901-634-4658 ii U,fpages lncludingfax vewor-shave 2 Thank yore, James Al Garner Rpr 24 2009 7:42RM RQURTIC DESIGN 16625600744 p.2 4w&e, 3227 dean Dr. Memphis, Tn 38118 901 795-3457 901-634-4658 April 24, 2009 .board of Health Yarmouth, Ma Re; VGB Act Compliance Hampton Inn Pools and Whirl Pool 99 Main St. West Yarmouth, Afa 02673 This letter is confirmation that the indoor swimmingpool, outdoor swimmingpool and Indoor whirlpool have been installed and are in compliance with The 2008 Virginia Graham Baker Act. Respecifull); James H..Garner President Aquatic De -sign and Construction Inc. Swimming Pool Specifications (1) Layout swimming pool and establish elevation as per plan. (2) Install pool perimeter header forms. (3) Excavate pool: Keep all dirt on site as needed (4) Install all rough in plumbing, light niches, drains, skimmers; return inlets, Polaris supply, and Hydrostatic relief valve. (5) Install all reinforcing steel: Steel to be #3 rebar tied on 10" centers walls and floor. #4 steel to be installed in bond beam. (6) Install electrical grounding for steel rebar, Light niches as per code. Secure inspection before installing Gunite. (7) Install complete Gunite structures. Gunite to be minimum 8 inches thick walls and floor. Bond beam to be 12" thick x12" wide. (8) Excavate all plumbing ditches and install all plumbing. Extend plumbing to filter area location. (9) All joints to be solvent welded, all pool piping ditches to be minimum 24" deep. (10) Pressure tests all piping. Piping to be tested to 601b phi. Maintain pressure for 24 hours. (11) After pressure test has passed for 24 hours, begin back filling with proper fill. Backfill to 8" depths and compact each layer before adding next layer, (12) Form for decks, grade decks, allowing for 4" concrete slab. Install concrete for slab as per plan. All concrete to be 4000 PHI concrete w/fiber mesh. (13) Finish decks and patio to be exposed aggregate concrete w/acrylic sealer. (14) Install all waterline tiles. Tile to be owner's choice. Tile to be frost proof ceramic tile. (15) Install 8' diving board. (16) Install vole caulking between pool coping and all decks. (17) Install all swimming pool circulation equipment, Polaris and sanitizing equipment. (See equipment list). (18) Clean swimming pool structure, prepare surface for marcite plaster finish. (19) Install 2"x2" tile border on all under water seats and steps. (20) Install marcite plaster finish in pool: (21) Fill pool immediately after marcite has set. (22) Balance pool chemicals (23) Install backwash line to filter equipment Swimming Pool Equipment (1) 1- 53 Esq. Sta- Rite System 3 D.E. Filter. (2)1-2 Multi port Valve. (3) 1-% h.p. Sta Rite Pump. (4)1-Automatic Chlorinator (5) 2 — Sta — Rite Surface Skimmers (6)1— Main drain w / Grate (7) 5 — Directional Flow Inlets (8) 1 —1 % Polaris wall Fitting (9)1- 500 wt. Pool Light (10)1- Pool Light Niche 1)1-U Frame Diving Board Stand (12)1- 8' Diving Board (13)1- Hydrostatic Relief (14) 4-2 way Jandy Valves (2") (15)1-24 hr. Timer for Polaris Automatic Cleaner (16)1- Polaris Motor (3/4 hip.) (17)1- Polaris Head and Hose (18)1- Vacuum Head (19)1- vacuum Plate (20)1- I % "x 40 Vacuum Hose (21)1-16' Telescopic Pole (22)1- Leaf Net (23)1- thermometer (24)1- Leaf Master (25)1- Safety Rope, 2 Anchors, 2 Hooks and 4 F7oats (26)1- Ozone Generator (27)1- automatic Water Controller (includes wiring) (28) All Start Up Chemicals (29) 2- Valve Boxes 4W/MC�" (a 3227 Jean Dr. Memphis, Tn 38118 901 795-3457 901-634-4658 April24, 2009 Board of Health Yarmouth, Ma Re: VGB Act Compliance Hampton Inn Pools and Whirl Pool 99 Main St. West Yarmouth, Ma 02673 This letter is confirmation that the indoor swimming pool, outdoor swimming pool and indoor whirlpool have been installed and are in compliance with The 2008 Virginia Graham Baker Act. Respectfully, James M. Garner President Aquatic Design and Construction Inc. Rpr 13 2009 9:28RM RQURTIC DESIGN 16625600744 p.l '&Owmra &.0 3227 A= Dr 1M[enWkis, Tip 38118 901-795--3457 APR 13 ?009 email aquadcdesign44@ iughes.met HEALTH DEPT. To : Bruce G. Murphy FY'an: lams M. Garner 41131109 Office Location Fax Number 508-76"472 ,Phone Number :901-795-3457 or 901-634-1658 # Qf pages including far cover sheet 4 Here are the drawings for the Hot ZWb at Hampton firs Su tie An FarmouthWo Call me at 901-674-4920 or 961-634-4658 O' jwo have any quesrtom I am sending you the infe radon for eke Salt Generators via your emalt Thank you, fames AGarner For I` - Day M Of Phone FAX AreatocTe MOBILE 1T MESSAGE _Time / /y lw� Area Code Number ?A�l Extension Extension Telephoned Returned your call RUSH Came to see you Please call Special attention Wants to see you Will call again Caller on hold Message U.S.A. Rpr 13 200S 9:28RM RQURTIC DESIGN 16625600744 P-2 5T L- A cTL c- -811 tq A-V j 17ri L <A,41 Rpr 13 2009 9:28RM RQURTIC DESIGN 16625600744 p.3 I'm a-47 �� Rpr 13 2009 9:28RM RQURTIG DESIGN 16625600744 P. 4 L4 c 3 ON