Loading...
HomeMy WebLinkAboutBLD-19-4153ALWAYS DIG SAFE PRIOR TO CONSTRUCTION --UTILITY LOCATIONS SHOWN INCOMPLETE. BATH M, UTIL BATH KIT. DNRM a RM CLOSET N le BDRM BDRM LVRM BDRM 0 0 M z J PROP. FLOOR PLAN NOT TO SCALE F+� Sh st x as ELLIS BROTHER'S CONST. �". 12 9 REPORTS OLD LEACHING DISCONNECTED x 13.0x 13.1 X 13.1 N /F ROBICHAUD 13.7 4. \ 4.0 \ \13.4 eIN \ \5 2 \ N /F MCGOVERN /2' WIDE STRIP VLOT31 Lot corner falls on Mazzone side of fence --stake set 6" off comer N /F on Lot 5 side of fence MAZZONE ZONING DISTRICT: R-25 FRONT YARD 30' SIDE YARD 15' SIDE YARD 15' BUILDING HEIGHT 35' LOT COVERAGE 25% JOB NO. Y18-14 NOTES Bevilacqua.dwg 1. LOCUS IS A.M. 30, PARCEL 77. FB32/2,13 SB14/8 2. ELEVATIONS SHOWN ARE NAVD88 BASED UPON RM20 AND VERTCON. 3. LOCUS IS IN FLOOD .ZONE X(<0.2% RISK) ON FIRM DATED JULY 16, 2014. 4. ALL PIPES TOBE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED) 5. MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER. 6. COMPONENTS TO BE AASHTOH-10, UNLESS NOTED. 7. INLET TEE TO 'PROJECT DOWN 13", OUTLET 'TEE DOWN 14'. 8. IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. 9. DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED. IS COVERS: BUILD UP COVERS TO 6" BELOW GRADE --2 ON TANK, 1 ON D -BOX, 1 ON LEACHING 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP. 11. IF UNSUITABLE, SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, CONTACT THE 'BOARD OF HEALTH, OR R.J. CADILLAC. 12. IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). TEST HOLE 1 13. PUMP AND FILL ANY EXISTING CESSPOOL/LEACHPIT. REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT. DEPTH (inches) ELEV.(feet) 14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. *LOT AREA IS ALL UPLAND AND PROPOSED TEST HOLE DATE: May 4, 2016 1 PERFORMED BY: Ron Cadillac, Soil Evaluator LOT COVERAGE=1845 S.F./10,749 S.F.=17.2% WITNESSED BY.• Amy Von Hone RS CHO 7.1 Top Slab -2. 1 11.04 _ 11. x 11.9 A=3g' 60� �• >x 12,1 10,87 x 55 �� „ 11 11.6 j 1T10 3 BENCH MARK -TOP FLS 1/0 • 10.99 OVER MAIN DISCHARGE= x 10.73 x 10,9 0 10.46 LEGEND T 1 TEST HOLE LOCATION, NUMBER BENCH MARK --MAG NAIL SET �G- PROPOSED GAS IN PAVEMENT=10.46 NAVD88 -f'W- PROPOSED WATER LINE E OVERHEAD ELECTRIC WIRES (IF SHOWN) x 9.5 EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT) • 16' 1 1 EXISTING CONTOUR 8-- PROPOSED CONTOUR UTILITY POLE (IF SHOWN) ® EXISTING DRAINAGE CATCH BASIN x - FENCE (IF SHOWN, NOT ALL SHOWN) 0 TREE (IF SHOWN, NOT ALL SHOWN) REV. 01/10/2019 --UPLAND LOT COVERAGE REV. 09/05/2018 --BUYER MODIFICATIONS REV. 03/16/2018--HGW ADJUSTED TO 58 CARVER RD. PERC RATE: <2'-00"/inch (C layer) 14.6 SOIL SURVEY(1993): Carver coarse sand 31 GEOLOGIC MAP(1986): Harwich outwash plain deposits - Top Found. � W Invert 11.15 12 ARC36HC HD CHAMBERS 48" Invert 11.75 Proposed Proposed H-10 Use Gas Baffle Invert 10.30 Proposed Top Units=10.7 S=1 /4 -/ft 9" min. cover 0 Filter Cloth Proposed S=5/8"/ft 3" Max. 1500 Gal. S=m�8"!ft _ Inspection Port 11 Invert 11.40 --� Proposed Septic Tank 10.75" 122 Invert 10.30 9.4 Invert 10.47 Proposed 5' Bottom 6" Stony or compact Proposed A layer 10yr 3/2 sandy loam B layer 10yr 6/6 loamy sand C layer 2.5y 6/3 med. coarse 'sand 8" observed w 12.7 10.2 1 .9 .5 '' �- i "' i TEST HOLE 2 • 16' 1 1 i 12'--4 -O, -i High Groundwater=4.4 I I 1 rn Taken from August 17, 2016 DEPTH (inches) ELEV.(fee DESIGN DATA < test hole data at cD 58 Carver Road _ 0 A/E layer 10yr 3/3 11.9 Observed Water=2.9 sandy loam BEDROOMS: 3 9.. GARBAGE GRINDER: No B layer 10yr 6/6 REQUIRED CAPACITY: 330 GPD loamy sand PROPOSED SEPTIC TANK, 1500 GAL. LEACH AREA 3, 9.3 EFFECTIVE TRENCH AREA: 467.4 S.F. USE 2 TRENCHES OF SIX ARC36HC HD "CHAMBERS 7.79 SF/LF X 5'/UNIT=38.95 SF EACH (30' X 34.5" WIDE AND 10.75" DEEP), AS C layer 2.5y 6/4 12 UNITS X 39.95 SF -L467.4 SF SHOWN. med. coarse sand CAPACITY: 345 GPD 467.4 SF X 0.74 GPD/SF DO 5' REMOVAL STONE TRENCHES DO 5' ALL AROUND REMOVAL OF A & B LAYERS 111" _obser_ved water 2 STONE TRENCHES 37' X 3; X 1'-5" DEEP COULD BE DOWN 2 1/2' TO MEDIUM COARSE SAND OR 125" INSTALLED (=332 GPD) IN SAME LOCATION BY BENDING PERC B LAYER AT TIME OF CONSTRUCTION. THE LAST 10' OF TRENCH 20' OFF FOUNDATION. THIS PLAN IS A VALID COPY ONLY IF IT BEARS AN OF3!-G+N-A� RED,,STAMP-AND SIGNATURE. HEALTH AGENT APPROVAL IF 114 RECEIVED JAN 1 2019 I BDILDING DEPARTMENT SITE PLAN ' By ' FOR PAUL J. BEVILACQUA LOT 59 62 CARVER ROAD, WEST YARMOUTH, MA SEPTEMBER 2, 2016 SCALE: 1"=20' RONALD J. CADILLAC, PLS, RS, P.C. PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 (508) 775-9700 PAGE 1 OF 1 2016 BY R.J. CADILLAC 7 .5 ALWAYS DIG SAFE PRIOR TO CONSTRUCTION --UTILITY LOCATIONS SHOWN INCOMPLETE. BATH M R BATH KIT. DNRM RM c�osET 0 N `VLVRM BDRM Y BDRM BDRM z PROP. FLOOR PLAN NOT TO SCALE Sheat X ELLIS BROTHER'S CONST. '` 12.9 REPORTS OLD LEACHING x 13.1 DISCONNECTED x 13,0 II X 13.1 I � . <� r ROBICHAUD 13.7 x / x 4. c� e� \� \ 4,0 S \ \13.45 x ROADHIGH' POINT --"13.5 I N/F ZONING DISTRICT: R-25 MCGOVERN FRONT YARD 30' SIDE YARD 15' SIDE YARD 0. ; 15' BUILDING HEIGHT 35' I OT COVFRAGF 25% /2' WIDE STRIP LOT 31 Lot corner falls on Mazzone side of fence --stake set 6 off corner N /F on Lot 5 side of fence \ MAZZONE �3.1 S S6. `3A • \ ?g. ry g0; 12, 14T7600^ .7 11.04 2 fols 11 �/ x 11.9 x 12 1 i -2 60 10.87 x .55 �lQ3 fT'10 - �\ 3 [;ENCH MARK --TOP FLS 10 x 10.99 OVER MAIN DISCHARGE= TH 1 TEST HOLE LOCATION, NUMBER IN P) --t'G-- PROPOSED GAS -f'W- ,PROPOSED WATER LINE E OVERHEAD ELECTRIC WIRES (IF SHOWN) x 9.5 EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT) Ron Cadillac, Soil Evaluator EXISTING CONTOUR g-- PROPOSED CONTOUR WITNESSED BY: UTILITY POLE (IF SHOWN) ® EXISTING DRAINAGE CATCH BASIN x - FENCE (IF SHOWN, NOT ALL SHOWN) <2'-00"/inch (C layer) TREE (IF SHOWN, NOT ALL SHOWN) REV, 09/05/2018 --BUYER MODIFICATIONS REV. 03/16/2018--HGW ADJUSTED TO 58 CARVER RD. JOB NO. Y18-14 NOTES Bevilacqua.dwg 1. LOCUS IS A.M. 30, PARCEL 77. FB32/2,13 SB14/8 2. ELEVATIONS SHOWN ARE NAVD88 BASED UPON RM20 AND VERTCON. 3. LOCUS IS IN FLOOD ZONE X(<0.2% RISK) ON FIRM DATED JULY 16, 2014. 4. ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4- PER FOOT. (UNLESS NOTED) 5. MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER. 6. COMPONENTS TO BE AASHTO-H-10, UNLESS NOTED. 7. INLET TEE TO PROJECT 'DOWN 13", OUTLET TEE DOWN 14". 8. IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. 9. DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED. COVERS: BUILD UP COVERS TO 6" BELOW GRADE --2 ON TANK, 1 ON D -BOX, 1 ON LEACHING 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP. 11. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. 12. IF AN OVERDIG IS CALLED FOR BELOW, FI MATERIAL FOR 5' AROUND AND UNDER I EACHING IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). TEST HOLE 1 13. PUMP AND FILL ANY EXISTING CESSPOOL LEACHPIT. REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT. DEPTH (inches) ELEV.(feet) 14 ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS 7 ,a N v 0 0 �a o - Carver Rd. NOT TO SCALE LOCATION MAP L T Invert 10.30 9.4 Invert 10.47 Proposed 5' Bottom 6" Stone or compact Proposed A layer 10yr 3/2 " sandy loam B layer 1Oyr 6/6 loamy sand C layer 2.5y 6/3 med. coarse sand _observed water " 10.2 TEST HOLE 2 16- 12' E --0,--a High Groundwater=4.4 ' I m j 0 Taken from August 17, 2016 DEPTH (inches) ELEV.(fee DESIGN DATA CD test hole data at CD 58 Carver Road 0 BEDROOMS: 3 GARBAGE GRINDER: No REQUIRED CAPACITY: 330 GPD PROPOSED SEPTIC TANK: 1500 GAL EFFECTIVE TRENCH AREA: 467.4 S.F 7.79 SF/LF X 5'/UNIT=38.95 SF 12 UNITS X 39.95 SF=467.4 SF CAPACITY: 345 GPD 467.4 SF X 0.74 GPD/SF STONE TRENCHES 2 STONE TRENCHES 37' X 3' X V-5" DEEP COULD BE INSTALLED (=352 GPD) IN SAME LOCATION BY BENDINi THE LAST 10' OF TRENCH 20' OFF FOUNDATION. THIS PLAN IS A VALID COPY ONLY IF IT BEARS AN ORIG U L RED STAMP ND SIGNATURE. . G �s1i HEALTH AGENT APPROVAL DATE Observed Water=2.9 9' LEACH AREA 31" USE 2 TRENCHES OF SIX ARC36HC HD CHAMBERS EACH (30' X 34.5" WIDE AND 10.75" DEEP), AS SHOWN. DO 5' REMOVAL DO 5' ALL AROUND REMOVAL OF A & B LAYERS 111' DOWN 2 1/2' TO MEDIUM COARSE SAND OR 125 PERC B LAYER AT TIME OF CONSTRUCTION. 11.9 A/E layer 10yr 3/3 sandy loam B layer 10yr 6/6 loamy sand 9.3 C layer 2.5y 6/4 med. coarse sand 1 _observed water _ 2.7 1.5 Yarmouth Health Department PP VED 1 . ame Date SITE PLAN FOR PAUL J BEVILACQUA LOT 59 62 CARVER ROAD WEST YARMOUTH MA SEPTEMBER 2, 2016 SCALE: 1 "-20, RONALD J. CADILLAC, PLS, RS, P.C. PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 @2016 BY R.J. CADILLAC (508) 775-9700 PAGE 1 OF 1 TEST HOLE DATE: May 4; 2016 1 PERFORMED BY: Ron Cadillac, Soil Evaluator WITNESSED BY: Amy Van Hone, RS, CHO PERC RATE: <2'-00"/inch (C layer) 14.6 SOIL SURVEY(1993): Carver coarse sand 31 Top. Found. GEOLOGIO MAP 1986: ( Harwich outwash Iain deposits ) p - p Invert 11.15 12 ARC36HC HD CHAMBERS 4A Invert 11.75 Proposed Proposed H-10 Use Gas Baffle Invert 10.30 Top Units=10.7 S=1 /4"/ft 9" min. cover Proposed 0 Filter Cloth S=5/8" ft _ 3" Max. S 1 /8"/ft inspection Part In=Proposed 11.40 Proposed 1500 Gal. Septic Tank L ^------�- �� 11E 10 75 12� L T Invert 10.30 9.4 Invert 10.47 Proposed 5' Bottom 6" Stone or compact Proposed A layer 10yr 3/2 " sandy loam B layer 1Oyr 6/6 loamy sand C layer 2.5y 6/3 med. coarse sand _observed water " 10.2 TEST HOLE 2 16- 12' E --0,--a High Groundwater=4.4 ' I m j 0 Taken from August 17, 2016 DEPTH (inches) ELEV.(fee DESIGN DATA CD test hole data at CD 58 Carver Road 0 BEDROOMS: 3 GARBAGE GRINDER: No REQUIRED CAPACITY: 330 GPD PROPOSED SEPTIC TANK: 1500 GAL EFFECTIVE TRENCH AREA: 467.4 S.F 7.79 SF/LF X 5'/UNIT=38.95 SF 12 UNITS X 39.95 SF=467.4 SF CAPACITY: 345 GPD 467.4 SF X 0.74 GPD/SF STONE TRENCHES 2 STONE TRENCHES 37' X 3' X V-5" DEEP COULD BE INSTALLED (=352 GPD) IN SAME LOCATION BY BENDINi THE LAST 10' OF TRENCH 20' OFF FOUNDATION. THIS PLAN IS A VALID COPY ONLY IF IT BEARS AN ORIG U L RED STAMP ND SIGNATURE. . G �s1i HEALTH AGENT APPROVAL DATE Observed Water=2.9 9' LEACH AREA 31" USE 2 TRENCHES OF SIX ARC36HC HD CHAMBERS EACH (30' X 34.5" WIDE AND 10.75" DEEP), AS SHOWN. DO 5' REMOVAL DO 5' ALL AROUND REMOVAL OF A & B LAYERS 111' DOWN 2 1/2' TO MEDIUM COARSE SAND OR 125 PERC B LAYER AT TIME OF CONSTRUCTION. 11.9 A/E layer 10yr 3/3 sandy loam B layer 10yr 6/6 loamy sand 9.3 C layer 2.5y 6/4 med. coarse sand 1 _observed water _ 2.7 1.5 Yarmouth Health Department PP VED 1 . ame Date SITE PLAN FOR PAUL J BEVILACQUA LOT 59 62 CARVER ROAD WEST YARMOUTH MA SEPTEMBER 2, 2016 SCALE: 1 "-20, RONALD J. CADILLAC, PLS, RS, P.C. PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 @2016 BY R.J. CADILLAC (508) 775-9700 PAGE 1 OF 1 ALWAYS DIG SAFE PRIOR TO CONSTRUCTION ----UTILITY LOCATIONS SHOWN INCOMPLETE. 5 AND LOCAL REGULATIONS. 0 JOB NO. Y18-14 12.7.. A layer 10yr 3/2 0 UTILITY POLE (IF SHOWN) ® *LOT NOTES Bevilacqua.dwg TEST HOLE DATE: BATH 12„ sandy loam REV. 03/16/2018--HGW ADJUSTED TO 58 CARVER RD. 1. ffR BATH KIT. DNRM a ZONING DISTRICT: R-25 2. ELEVATIONS SHOWN ARE NAVD88 BASED UPON RM20 AND VERTCON. a v 3t ° E aosEr N /F 3. LOCUS IS IN FLOOD ZONE X(<0.2% RISK) ON FIRM DATED JULY 16, 2014. 14.6 SOIL SURVEY(1993): Carver coarse sand 30" 4. M CGOVERN o FRONT YARD BDRM 5. LVRM BDRM 3 SIDE YARD BDRM 6. COMPONENTS TO BE AASHTO H'-10, UNLESS NOTED. Carver Rd. SIDE YARD 15' 7. " INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14-. m 8. IF TWO OR MORE LINES, WATERTEST D -BOX FOR EQUAL FLOW co BUILDING HEIGHT 35' D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. LOT COVERAGE 25% z DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED. NOT TO IL PROP . FLOOR PLAN 2' WIDE 10. E STRIP COVERS STO ILD UP COVERS TO DOUBLE WASHED 16" BELOW GRADE --2 ON TANK, 1 ON D -BOX, 1 ON LEACHING SCALE 3STONE NOT TO SCALE fLOT 3/4 TO 1 1/2" WITH 2 MIN. 1/8 TO 1/2" PEA STONE ON TOP. LOCATION MAP F�; `-•:•, 11. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, Shy st 13.3 CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. d Lot corner falls on MazzQne side 12. IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING of fence --stake set 6" off comer ELLIS BROTHER'S CONST. • N/F IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). TEST HOLE 1 REPORTS OLD LEACHING 12.9 \on Lot 5 side of fence 13. PUMP AND FILL ANY EXISTING CESSPOOL/LEACHPIT. REMOVE ANY CLOGGED SOIL, BLOCK, DISCONNECTED ' 13,1 x 13,0 MAZZONE AND STONE. IN LEACH AREA, AND DISPOSE_ OF AS DIRECTED BY HEALTH AGENT. DEPTH (inches) ELEV.(feet) ■ `� \3.1 ROBICHAUD TH 1 x 1 013 -0- -0b, .7 x13,4 \ 03.3 14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. 0 JOB NO. Y18-14 12.7.. A layer 10yr 3/2 0 UTILITY POLE (IF SHOWN) ® *LOT NOTES Bevilacqua.dwg TEST HOLE DATE: a 12„ sandy loam REV. 03/16/2018--HGW ADJUSTED TO 58 CARVER RD. 1. LOCUS IS A.M. 30, PARCEL 77. COVERAGE=1845 S.F./10,749 SF.=17.2% FB32/2,13 SB14/8 ' o N a ZONING DISTRICT: R-25 2. ELEVATIONS SHOWN ARE NAVD88 BASED UPON RM20 AND VERTCON. a v 3t ° E <2'-00"/inch (C layer) loamy sand 3. LOCUS IS IN FLOOD ZONE X(<0.2% RISK) ON FIRM DATED JULY 16, 2014. 14.6 SOIL SURVEY(1993): Carver coarse sand 30" 4. ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED) v ° FRONT YARD 30' 5. MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER. 10.2 3 SIDE YARD 15' 6. COMPONENTS TO BE AASHTO H'-10, UNLESS NOTED. Carver Rd. SIDE YARD 15' 7. " INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14-. v 8. IF TWO OR MORE LINES, WATERTEST D -BOX FOR EQUAL FLOW co BUILDING HEIGHT 35' D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. LOT COVERAGE 25% 9. DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED. NOT TO IL PROP . FLOOR PLAN 2' WIDE 10. E STRIP COVERS STO ILD UP COVERS TO DOUBLE WASHED 16" BELOW GRADE --2 ON TANK, 1 ON D -BOX, 1 ON LEACHING SCALE 3STONE NOT TO SCALE fLOT 3/4 TO 1 1/2" WITH 2 MIN. 1/8 TO 1/2" PEA STONE ON TOP. LOCATION MAP F�; `-•:•, 11. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, Shy st 13.3 CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. d Lot corner falls on MazzQne side 12. IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING of fence --stake set 6" off comer ELLIS BROTHER'S CONST. • N/F IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). TEST HOLE 1 REPORTS OLD LEACHING 12.9 \on Lot 5 side of fence 13. PUMP AND FILL ANY EXISTING CESSPOOL/LEACHPIT. REMOVE ANY CLOGGED SOIL, BLOCK, DISCONNECTED ' 13,1 x 13,0 MAZZONE AND STONE. IN LEACH AREA, AND DISPOSE_ OF AS DIRECTED BY HEALTH AGENT. DEPTH (inches) ELEV.(feet) ■ `� \3.1 ROBICHAUD TH 1 x 1 013 -0- -0b, .7 x13,4 \ 03.3 o x 12,8 Use Gas Baffle Invert 10.30 ' �, 3,6 13.2 To Slab Proposed H-10 Proposed .moo' 12.8 p P Top Units=10.7 �� ��/s �� ��/ ry o S=1 �4»�ft 9" min. cover ®Filter Cloth :.. 12.8 J c4• Proposed S=5/8 /ft 3 Max. 12, rS=1/8 /ft 1- Ins Inspection Port observed water LOT 5 2,1 11, Invert 11.40 1500 Gal. r p 118" ------------ 2.9 C o8• O'2 Septic Tank min ::• -^7 o _:. �:: Proposed 10,749 49 `� S. �Q Q, �C TH 2 / ::... / t,71 ------ 10.75" 122" 2.5 13,7 Cij �' O o o�� / /:::::::: / T ti :43j: Invert 10.30 9.4 Q O Invert 10.47 ._ 3 » Proposed 5' Bottom O 6 Stone or compact Proposed 3.7 x 12.9 <Z 0°�/ / I I I N I 0' TEST HOLE 2 / $, x.: i:t::7; / I 16 I 1L- 12 - _ [_0"-•-1 High Groundwater=4.4 C� .5 11.5 rn Taken from August 17, 2016 DEPTH (inches) ELEV.(feet) < test hole data at Stake DESIGN DATA 58 Carver Road 0 . ti Observed Water -2.9 4,0 Set 13.7 / �� / :: �`1% O • JL5 9 \ \ \13.4 f O '' / BEDROOMS: 3 �.5 x 13'5 �0 io \ �/ -� o, / GARBAGE GRINDER: No \ O , / 1�.3 REQUIRED CAPACITY: 330 GPD X 13. x 1�7 NS 50.7 Q �' �:: /� LEACH AREA 31' S i 3 r ::J x PROPOSED SEPTIC TANK: 500 GAL. F\ �O Q��o::' . 2,1 2 EFFECTIVE TRENCH AREA: 467.4 S.F. USE 2 TRENCHES OF SIX ARC36HC HD CHAMBERS �i3,1'�y xQr3.2Q "� , _ �a. 11.04 7.79 SF/LF X 5'/UNIT=38.95 SF EACH (30' X 34.5" WIDE AND 10.75" DEEP), AS �12 UNITS X 39.95 SF=467.4 SF SHOWN. CAPACITY: 345 GPD \ 3.0 467.4 SF X 0.74 GPD/SF 1� S2 \o DO 5' REMOVAL 9.6 o DO 5 ALL AROUND REMOVAL OF A & B LAYERS 111' \ �2x 12,1 R-25.5 �/ 10,87 x 1, 55 STONE TRENCHES DOWN 2 1/2' TO MEDIUM COARSE SANDOR 2 STONE TRENCHES 37 X 3 X 1'-5" DEEP COULD BE 125 11.9 9.3 2.7 1.5 INSTALLED (=332 GPD) IN SAME LOCATION BY BENDING PERC B LAYER AT TIME OF CONSTRUCTION. r .1 0, 4 THE LAST 10 OF TRENCH 20 OFF FOUNDATION. x 1 63 BENCH MARK --•TOP FLANGE BOLT . 10,99 OVER MAIN DISCHARGE=13.36 NAV ROAD HIGH POINT=13.5 x 10.73 x 10.9 LEGEND TH 1 TEST HOLE LOCATION, NUMBER BENCH MARK --MAG NAIL SET PG- PROPOSED GAS IN PAVEMENT=10.46 NAVD88 -PW- PROPOSED WATER LINE E 14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. 0 EXISTING CONTOUR 12.7.. A layer 10yr 3/2 0 UTILITY POLE (IF SHOWN) ® *LOT AREA IS ALL UPLAND AND PROPOSED FENCE (IF SHOWN, NOT ALL SHOWN) TEST HOLE DATE: May 4, 2016 12„ sandy loam REV. 03/16/2018--HGW ADJUSTED TO 58 CARVER RD. LOT COVERAGE=1845 S.F./10,749 SF.=17.2% PERFORMED BY: WITNESSED BY: Ron Cadillac, Soil Evaluator Amy Von Hone, RS, CHO B layer 10yr 6/6 PERC RATE: <2'-00"/inch (C layer) loamy sand 14.6 SOIL SURVEY(1993): Carver coarse sand 30" Top Found. GEOLOGIC MAP(1986): Harwich outwash plain deposits 10.2 2.8 7.1 Invert 11.75 Invert 11.15 Proposed 12 ARC36HC HD CHAMBERS 48" q C layer 2.5y 6/3 med. coarsesand o x 12,8 Use Gas Baffle Invert 10.30 ' �, 3,6 13.2 To Slab Proposed H-10 Proposed .moo' 12.8 p P Top Units=10.7 �� ��/s �� ��/ ry o S=1 �4»�ft 9" min. cover ®Filter Cloth :.. 12.8 J c4• Proposed S=5/8 /ft 3 Max. 12, rS=1/8 /ft 1- Ins Inspection Port observed water LOT 5 2,1 11, Invert 11.40 1500 Gal. r p 118" ------------ 2.9 C o8• O'2 Septic Tank min ::• -^7 o _:. �:: Proposed 10,749 49 `� S. �Q Q, �C TH 2 / ::... / t,71 ------ 10.75" 122" 2.5 13,7 Cij �' O o o�� / /:::::::: / T ti :43j: Invert 10.30 9.4 Q O Invert 10.47 ._ 3 » Proposed 5' Bottom O 6 Stone or compact Proposed 3.7 x 12.9 <Z 0°�/ / I I I N I 0' TEST HOLE 2 / $, x.: i:t::7; / I 16 I 1L- 12 - _ [_0"-•-1 High Groundwater=4.4 C� .5 11.5 rn Taken from August 17, 2016 DEPTH (inches) ELEV.(feet) < test hole data at Stake DESIGN DATA 58 Carver Road 0 . ti Observed Water -2.9 4,0 Set 13.7 / �� / :: �`1% O • JL5 9 \ \ \13.4 f O '' / BEDROOMS: 3 �.5 x 13'5 �0 io \ �/ -� o, / GARBAGE GRINDER: No \ O , / 1�.3 REQUIRED CAPACITY: 330 GPD X 13. x 1�7 NS 50.7 Q �' �:: /� LEACH AREA 31' S i 3 r ::J x PROPOSED SEPTIC TANK: 500 GAL. F\ �O Q��o::' . 2,1 2 EFFECTIVE TRENCH AREA: 467.4 S.F. USE 2 TRENCHES OF SIX ARC36HC HD CHAMBERS �i3,1'�y xQr3.2Q "� , _ �a. 11.04 7.79 SF/LF X 5'/UNIT=38.95 SF EACH (30' X 34.5" WIDE AND 10.75" DEEP), AS �12 UNITS X 39.95 SF=467.4 SF SHOWN. CAPACITY: 345 GPD \ 3.0 467.4 SF X 0.74 GPD/SF 1� S2 \o DO 5' REMOVAL 9.6 o DO 5 ALL AROUND REMOVAL OF A & B LAYERS 111' \ �2x 12,1 R-25.5 �/ 10,87 x 1, 55 STONE TRENCHES DOWN 2 1/2' TO MEDIUM COARSE SANDOR 2 STONE TRENCHES 37 X 3 X 1'-5" DEEP COULD BE 125 11.9 9.3 2.7 1.5 INSTALLED (=332 GPD) IN SAME LOCATION BY BENDING PERC B LAYER AT TIME OF CONSTRUCTION. r .1 0, 4 THE LAST 10 OF TRENCH 20 OFF FOUNDATION. x 1 63 BENCH MARK --•TOP FLANGE BOLT . 10,99 OVER MAIN DISCHARGE=13.36 NAV ROAD HIGH POINT=13.5 x 10.73 x 10.9 LEGEND TH 1 TEST HOLE LOCATION, NUMBER BENCH MARK --MAG NAIL SET PG- PROPOSED GAS IN PAVEMENT=10.46 NAVD88 -PW- PROPOSED WATER LINE E OVERHEAD ELECTRIC WIRES (IF SHOWN) x 9.5 EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT) 6 EXISTING CONTOUR 8"- PROPOSED CONTOUR 0 UTILITY POLE (IF SHOWN) ® EXISTING DRAINAGE CATCH BASIN x - FENCE (IF SHOWN, NOT ALL SHOWN) 0 TREE (IF SHOWN, NOT ALL SHOWN) REV. 01/10/2019 --UPLAND LOT COVERAGE REV. '09/05/2018 --BUYER MODIFICATIONS REV. 03/16/2018--HGW ADJUSTED TO 58 CARVER RD. 10.46 THIS PLAN IS A VALID COPY ONLY IF IT BEARS AN ORI RED STAMP AND SIGNATURE, Lit- A4,q , �I(A OF hf,4 RONALD yes RONALD Gm�' o JAMES `�`, o JAMES CADILLAC " CADILLAC # 1060 p # 35779 I FFG/STEEL�o !9 'cfSS\0 pQ SANITARO' ID f' M�SURJ L-TH AGENT APPROVAL HATE SITE PLAN FOR PAUL J. BEVILACQUA LOT 59 62 CARVER ROAD, WEST YARMOUTH, MA SEPTEMBER 2, 2016 SCALE: 1 "=20' RONALD J. CADILLAC, PLS, RS, P.C. PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 (508) 775-9700 PAGE 1 OF 1 2016 BY Ri J. CADILLAC ALWAYS DIG SAFE PRIOR TO CONSTRUCTION --UTILITY LOCATIONS SHOWN INCOMPLETE. BATH 01 n' RML BAJ KIT. DNRM C3 CLOSET a-. 0 N Y'BDRM BDRM LVRM BDRM 0 0 M z PROP. FLOOR PLAN NOT TO SCALE F+� She s� ..- ` x ELLIS BROTHER'S CONST. ' , REPORTS OLD LEACHING DISCONNECTED .1. " 13.1 X 13.1 N F ROBICHAUD , G 13.7 4. C) N /F MCGOVERN 2' WIDE STRIP LOT 31 ZONING, DISTRICT: R-25 FRONT YARD 30' SIDE YARD 15' SIDE YARD 15' BUILDING HEIGHT 35' LOT COVERAGE 25% ' Lot corner falls on Mazzone side of fence --stake set 6" off corner N fF on Lot 5 side of fence MAZZQNE 1 S S62g, V 70 g0' QO,. 2.7 7.1 Top Slab 0 .1 11,04 o 14. STRUCTION JOB NO. Y18-14 • ' NOTES Bevilacqua.dwg o x 9.51 EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT) --16-� 1. LOCUS IS A.M. 30, PARCEL 77. F832/2,13 S614/8 o N v 2. ELEVATIONS SHOWN ARE NAVD88 BASED UPON RM20 AND VERTCON. 3 3. LOCUS IS IN FLOOD ZONE X(<027. RISK) ON FIRM DATED JULY 16, 2014. v ° t` 4. ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED) o -° 5. MUNICIPAL. WATER IS AVAILABLE LOTS WITHIN 100' ARE ON TOWN WATER. - C010, 6. COMPONENTS TO BE AASHTO H-IUNLESS NOTED. c Carver Rd. 7. `INLET TEE TO PROJECT DOWN 13 , OUTLET TEE DOWN 14" . a 8. IF TWO OR MORE LINES, WATER ST D -BOX FOR EQUAL FLOW B layer 10yr 6/6 D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. 9. -DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST -BE PROVIDED. NOT TO foamy sand COVERS: BUILD UP COVERS TO 6" BELOW GRADE --2 ON TANK, 1 ON D -BOX, 1 ON LEACHING SCALE 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP. LOCATION MAP 11. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, 10.2 CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. 12. IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). TEST HOLE 1 13. PUMP AND FILL ANY EXISTING CESSPOOL/LEACHPIT. REMOVE ANY CLOGGED SOIL, BLOCK, L AND STONE IN LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT. DEPTH (inches) ELEV.(feet) TO MEET TITLE 5 AND LOCAL REGULATIONS ALL CON PROPOSED GAS • 0 A 'layer 10yr 3/2 12.7 x 9.51 EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT) --16-� EXISTING CONTOUR g-- sandy loam UTILITY POLE (IF SHOWN) ® EXISTING DRAINAGE CATCH BASIN TEST HOLE DATE: May 4, 2016 12" 0 TREE (IF SHOWN, NOT ALL SHOWN) REV. 09/05/2018 --BUYER MODIFICATIONS REV. 03/16/2018--HGW ADJUSTED TO 58 CARVER RD. PERFORMED BY. Ron Cadillac, Soil Evaluator WITNESSED BY: Amy Von Hone, RS, CHO B layer 10yr 6/6 PERC RATE: <2'-00"/inch (C layer) foamy sand 14.6 SOIL SURVEY(1993): Garver coarse sand 30" 10.2 GEOLOGIC MAP(1986): Harwich outwash plain deposits L C layer 2.5y 6/3 Invert 11.15 12 ARC36HC HD CHAMBERS 48"� 5 Proposed med. coarse` sand Vne; H-10 Use Gas Baffle Invert 10.30 Top Units=10.7 /ft9" min. cover Proposed ® Filter Cloth Proposed " S=5/8"/ft '3" Max. S=1 /8 /ft ✓ Inspection Port observed water .40 1500 Gal. mm. X17 T 118" ----------- 2.9 Proposed Septic Tank 10.75" 122" 2.5 Invert 10.30 9.4 6" Stone or compact Invert 10.47 Proposed 5' Bottom Proposed i ' TEST HOLE 2 16 I ' 1 , , N , , �- 12 ---a 1--0 '--I High Groundwater=4.4 0 I co Taken from August 17, 2016 DEPTH (inches) ELEV.(feet) < test hole data at 9, 9 DESIGN DATA CD 58 Carver Road Observed 'Water -2.9 BEDROOMS: 3 GARBAGE GRINDER: No REQUIRED CAPACITY: 330 GPD LEACH AREA 3 PROPOSED SEPTIC TANK: 100 GAL EFFECTIVE TRENCH AREA: -67.4 S,F. USE 2 TRENCHES OF SIX ARC36HC HD CHAMBERS 7.79 SF/LF X 5'/UNIT=38.95 SF EACH (30' X 34.5" WIDE AND 10.75" DEEP), AS 12 UNITS X 39.95 SF=467.4 SF SHOWN. CAPACITY: 345 GPD 467.4 SF X 0.74 GPD/SF x 11.9 DO 5' REMOVAL STONE TRENCHES DO V ALL AROUND REMOVAL OF A & B LAYERS 1 O >x 1�R-2 / l0 87 55 �-- E TRENCHES 37 3 EE X X 1 5 PP COULD BE DOWN 2 1/2' TO MEDIUM COARSE SAND OR 12 A/E layer 10yr 3/3 sandy loam 9 B layer 1Oyr 6/6 loamy sand 1" 9. C layer 2.5y 6/4 med. coarse sand 11" -observed water --2. 11.6 2 STON PERC B LAYER AT 11ME OF CONSTRUCTION. ✓ INSTALLED (=332 GPD) IN SAME LOCATION BY BENDING 1 'l0 / THE LAST 10' OF TRENCH 20' OFF FOUNDATION. 3 BENCH MARK --TOP FLANGE BOLT Yarmouth Health Department x 10 99 OVER MAIN DISCHARGE=13.36 NAVD88 PPR X _ =low] x 10.73 10.46 LEGEND/ BENCH MARK --MAG NAIL SET T 1 TEST HOLE LOCATION, NUMBER IN PAVEMENT=10.46 NAVD88 PG-- PROPOSED GAS -PW- PROPOSED WATER LINE E OVERHEAD ELECTRIC WIRES (IF SHOWN) x 9.51 EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT) --16-� EXISTING CONTOUR g-- PROPOSED CONTOUR UTILITY POLE (IF SHOWN) ® EXISTING DRAINAGE CATCH BASIN x - FENCE (IF SHOWN, NOT ALL SHOWN) 0 TREE (IF SHOWN, NOT ALL SHOWN) REV. 09/05/2018 --BUYER MODIFICATIONS REV. 03/16/2018--HGW ADJUSTED TO 58 CARVER RD. WORK MUS C NFORM ITO ALL 01 TOWN BY W & REGULATI NS Name SITE PLAN VARMOUT I WATER DEPT DAT FOR THIS PLAN IS A VALID -COPY ONLY IF IT BEARS PAUL � BEVILACQUA AN�RtGt3L RED SiT AND SIGNATURE. H OF Mgss9�XZN OF lygss' ?ti RONALD cyGN� ��°� RONALD JAMESa JAMES CADILLAC CA " CADILLAC # 1060 �, # 35779 r FGISTS ti !q OA' ESS OQ- SANITARtPN I SI r �O SURv�r HEALTH AGENT APPROVAL Date LOT 59 62 CARVER ROAD, WEST YARMOUTH, MA SEPTEMBER 2, 2016 SCALE: 1"=20' RONALD J. CADILLAC, PLS, RS, P.C. PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 DATE (508) 775-9700 PAGE 1 OF 1 C 2016 BY R.J. CADILLAC 3