Loading...
HomeMy WebLinkAboutEngineered Plan - 2019ELEV, 1500 GAL SEPTIC TANK 6" OF STONE UNDER OR ECHANICALLY COMPACTED) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN KITCHEN LIVING BED BAT ROOM ( ROOM DECK DINING F BED AREA DEN BATH ROOM E SECOND OUTLET iArr / ' PIPE UNDER BASEMENT / 92 / FLOOR TO BE RAISED AND P4VM OSFD i R TO FRONT OF;H SE 1 90 88 ` CNINGRNG AD 0 KEY: EXISTING CONTOUR: - - - - PROPOSED CONTOUR: ............. EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: * UTILITY POLE: -o- FENCE LINE: - HYDRANT: RETAINING WALL: o 4 LOCATION MAP LOT 69 (10,999 SF) ASSESSORS MAP: 115 PARCEL: 172 PLAN BOOK: 187, PAGE: 149 33.5' LEACH AREA DETAIL N � � I � I I I 106 104 o , I O I p�a9 Ly 1 SEPTIC SYSTEM DESIGN SEPTIC SYSTEM SECTION FLOW ESTIMATE: FIRST FLOOR TCOVERS WITHIN 6" 2 BEDROOMS AT 110 GAL / DAY = 220 GAL / DAY 107.06 / \ OF FINISHED GRADE TOP OF R SEPTIC TANK: R FOUNDATION 220 GAL / DAYx_ DAYS = 440 GAL 2 OUTLET PIPES 1/8" per ft USE 1500 GALLON SEPTIC TANK 104.73�EXISTING) 104.0 ROPOSEDD ELEV. a LEACHING AREA: (3 BEDROOM MINIMUM DESIGN) USE 3 - 500 GALLON CHAMBERS (8.5' x 4.8' x 2' EFF. DEPTH) WITH 2' OF STONE AROUND SIDES AND 4' AT ENDS (8.8' x 33.5' x 2') SIDE AREA: (8.8' + 335) x 2 x 2 = 169 SF (0.74) = 125 GAL/DAY BOTTOM AREA: 8.8' x 33.5' = 295 SF (0,74) = 218 GAL/DAY PLUMBER TO CONFIRM CAPACITY = 343 GAL/DAY PLUMBING CHANGE PRIOR TO CONSTRUCTION o� \f I O 100 98 lu <co �ti 0SF P N� ST �Q 2 e \\ DRI�FD - o��0 �\ co 108 10GA/'> yG .' I ?�p�0o I 96 r 2 Sla= 94 ITH C� ! BENCHMARK AT 108 I� LEFT CORNER OF BRICK STEP ELEVATION = 107.26 i EXISTING FLOOR PLAN V(1 MAX. 1/8" per ft MIN) (1 03_53 71T�� 1/8"per ft D-BOX ��", . 6" OF STONE UNDER OR MECHANICALLY COMPACTED) ELEV -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS MCLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 1-2-19 PERCOLATION RATE: < 2 MIN/IN PEASTONE OR FILTER FABRIC 3/4" - 1 1/2" DOUBLE WASHED STONE /-INSPECTION PORT ,-- ELEV.= 103.92 keffill1° °°°° °°°I'IM101.09 H H ELEV. 4' 4' 8' x 33.5" 3 - 500 GALLON CHAMBERS WITH 2' OF STONE AROUND SIDES AND 4' AT ENDS (8.8' x 33.5' x 2' DEEP) TH-1 106.0 FILL ELEV. A HORIZON LOAMY SAND 10YR 3/2 104.0 B HORIZON LOAMY SAND 10YR 6/8 103.0 C HORIZON MEDIUM SAND 2.5Y 7/4 PERCC AT 48" NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/8" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D-BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3' WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY, 13. EXISTING CESS POOLS ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED. cprloweri f�/N ;o q�NC jf d I ; // i l I /l �� ��'p��irr FRONT YARD CESS POOL LOCATION APPROXIMATE. LOCATE AT TIME OF CONSTRUCTION. ln�ert 104'3 1p15� , 0 j j / ' ♦ f /l /l J/ �� 86 O/�� 14, D; BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. / ✓ / Gj _ Garr 15.4 PVC SEWER PIPE TO BE ENCASED WITHIN A 6' CORRUGATED PVC PIPE WHEN WITHIN � / � f 98 / cf f l l / " F,Orr � / 10' OF THE EXISTING WATER SERVICE. ENCASE PIPE i l.�sfo �a 94 (SEE NOTE 15) / i ��¢a : 104 t `sae / f / / Permct'wand for REPAIR 01' SEI'T'IC SYSTEM 100 f / 92 f / / ONI Y, due to Stake and I..ucal septic. variances. 102 90 / Board of health review and approval is required for 88 86 any future additions/rena)satiui�s/alterations to �✓ 100, / / li I (z'J sewage��facilities and/or structures/dwellrng. Yarmouth Health Department o� REQUIRED VARIANCES FROM TITLE FIVE: 1. SECTION 15.211 (1): LEACH AREA TO BE LESS THAN 20' FROM CELLAR WALL (VARIANCE OF 5'). 2. SECTION 15.211 (1): LEACH AREA TO BE LESS THAN 10' FROM LOT LINE (VARIANCE OF 4'). M18-79 \ \ WETLAND ` a SITE PLAN a LOCATION: s° 6 SHAKER HOUSE RD., YARMOUTHPORT, MA THOMA.SJ. ��, PREPARED FOR: i�cLELLRN m civil ROBERT & JENE KOHR + No.36471 DATE: 1-3-19 SCALE: 1" = 20'