HomeMy WebLinkAboutEngineered Plan - 2019CONSTRUCTION NOTES MINIMUM 20" DIAMETER CONCRETE YARMOUTH, MA MINIMUM 20" DIAMETER COVERS COVERS RAISED TO WITHIN 6" OF TOP OF FND. Histori EL=50.0± RAISED TO WITHIN 6" OF FINISH FINISH GRADE (OR AS NOTED) Brook 1.) ALL WORK SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE TITLE 5 (310 CMR 15.000, c, STANDARD REQUIREMENTS FOR THE SITING, CONSTRUCTION, INSPECTION, UPGRADE, AND GRADE (OR AS NOTED) Road '''�01 EXPANSION OF ON -SITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS AND FOR THE TRANSPORT a EL=49.4± EL=49.5± a S ° AND DISPOSAL OF SEPTAGE, AND THE LOCAL BOARD OF HEALTH REGULATIONS. , ��\\\/\\�//\\�/\\�./ �j \�/\X/ EL=46.5± LOCUS 2.) ANY SEPTIC SYSTEM COMPONENT INSTALLED IN A LOCATION WHERE THERE IS POTENTIAL FOR i/i,� \�� VEHICLES OR HEAVY EQUIPMENT TO PASS OVER IT SHALL BE DESIGNED TO WITHSTAND AN H-20 //` / /� o„ Saturn L ° N.O LOADING. IF UNDER AN IMPERVIOUS SURFACE, SYSTEM SHALL BE VENTED TO THE ATMOSPHERE. d s � = � 48.1± 45.0 ^ `n GEO BRICLE �ooa �o`� J� 3.) TO MINIMIZE UNEVEN SETTLING, SEPTIC TANKS AND D-BOX SHALL BE INSTALLED ON A STABLE MECHANICALLY -COMPACTED BASE ON SIX INCHES OF CRUSHED STONE. t _ / EL = 45.0 C �° 4.) COVERS OVER THE INLET AND OUTLET TEES OF THE SEPTIC TANK, THE DISTRIBUTION BOX, AND 15' M i n THE SOIL ABSORPTION SYSTEM SHALL BE RAISED TO WITHIN 6 OF FINAL GRADE. LEACHING 47•3± F Slope Breakout 46.9 44.97 44.8 FIELDS, TRENCHES, AND OTHER SOIL ABSORPTION SYSTEMS WITHOUT ACCESS MANHOLES SHALL o _ 46.7 3/4" to SITE LOCUS N 44.5 �' N 1-1/2" STONE HAVE AT LEAST ONE (1) INSPECTION PORT CONSISTING OF PERFORATED 4 PVC PIPE PLACED DB_3 (Double wash) NOT TO SCALE VERTICALLY TO THE BOTTOM OF THE SOIL ABSORPTION SYSTEM WITH A CAP, TIED WITH MAGNETIC GAS BAFFLE H-20 Rated ✓ MARKING TAPE, ACCESSIBLE TO WITHIN 3" OF FINAL GRADE. p THREE (3) H2O 500 GALLON PRECAST D - B 0 X 42.5 ` ) , Estimated High Groundwater Calculation 5.) PIPING SHALL CONSIST OF 4" SCHEDULE 40 PVC OR EQUIVALENT. PIPE SHALL BE LAID ON A CONCRETE LEACH CHAMBERS WITH 2 OF Index Well Mif{ W-29 Zone A MINIMUM CONTINUOUS GRADE OF NOT LESS THAN 2% FROM THE BUILDING TO THE SEPTIC TANK, 11'± --� �--15'± � STONE ON ENDS AND 2.5' ON SIDES Date of Reading t2/1$ AND NOT LESS THAN 1 % OTHERWISE. 1,000 GALLON 101 1 Depth to Groundwater SEPTIC TANK 5.0 Groundwater Adjustment t.5 7.95 6.) DISTRIBUTION LINES FOR A LEACHING FIELD (SAS) SHALL BE 4" DIAMETER SCHEDULE 40 LEACH CHAMBERS Actual Groundwater Level 36.0 PVC (OR EQUIVALENT) LAID AT 0.005 FT/FT. UNLESS OTHERWISE NOTED. LINES SHALL BE CAPPED (EXISTING) (END VIEW) Estimated High Groundwater 37.5 AT END OR AS NOTED FOR LEACHING FIELDS. FLOW PROFILE 7.) LINES FROM THE DISTRIBUTION BOX TO BE LEVEL FOR THE FIRST TWO (2) FEET BEFORE NOT TO SCALE EL=37.5 Ado. Water EL=36.0 Ground Wa PITCHING TO THE SOIL ABSORPTION SYSTEM. DISTRIBUTION BOX SHALL BE WATER TESTED TO ter ASSURE EVEN DISTRIBUTION. EL=34.7 Bottom Test Hole 8.) GROUT TO BE USED AT ALL POINTS WHERE PIPES ENTER OR LEAVE ALL CONCRETE STRUCTURES 1.) Assessor's Map 50 Parcel 54 IN ORDER TO PROVIDE A WATERTIGHT SEAL. 2.) Book 26415 Page 158 - 9.) HEAVY EQUIPMENT SHALL NOT BE ALLOWED TO OPERATE OVER THE LIMITS OF THE SEWAGE 3.) Plan Book 200 Page 41 DISPOSAL FIELD DURING THE COURSE OF CONSTRUCTION OF THE SYSTEM. I 4.) This property is not in a Zone II 10.) IN ACCORDANCE WITH 310 CMR 15.221, ALL SYSTEM COMPONENTS SHALL BE MARKED WITH I Water District. MAGNETIC MARKING TAPE. I Assessors Map 50 5.) This property is in Flood Zone X I Parcel 58 11.) THERE ARE NO KNOWN WELLS WITHIN 150 OF THE PROPOSED SOIL ABSORPTION SYSTEM. Assessors Mop 50 12.) FROM THE DATE OF THE INSTALLATION OF THE SOIL ABSORPTION SYSTEM UNTIL RECEIPT OF Parcel 59 j THE CERTIFICATE OF COMPLIANCE, THE PERIMETER SHALL BE STAKED AND FLAGGED TO PREVENT USE OF THE AREA THAT MAY CAUSE DAMAGE TO THE SYSTEM. 48 1 13. THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM AS DESIGNED UNLESS 1 1 110.00' ) 5o N 86'38'10" E (46.9) (471) CONSTRUCTED AS SHOWN ON PLAN. ANY CHANGES SHALL BE APPROVED IN WRITING BY THE +l t '') T6� j� 149.7) 46 DESIGNER. (Sa6) IT 'a po / _ 14•) THE BOARD OF HEALTH REQUIRES INSPECTION OF ALL CONSTRUCTION BY AN AGENT OF THE - --1 �il ° 11 e � g.�' ° °° ° _ _ 445 _._.. I t 11 ° o o°o �9 Is' BOARD OF HEALTH AND THE DESIGNER. THE DESIGNER SHALL- kCERTIFY tN WRITING THAT THE - ' - 1 Shed I M,o ° 5` O/44 )` ¢ a4 Obs SEWAGE DISPOSAL SYSTEM WAS INSTALLED IN ACCORDANCE WITH THE TERMS OF THE PERMIT I� o b ® �� 'Hol l- - -�\ec 8 Test Hole AND THE APPROVED PLANS. 48 HOURS ADVANCE NOTICE IS REQUESTED. 509) / ' ; = `° s F�'sit a (42.4 42 15.) LOCATION OF UTILITIES IS APPROXIMATE AND CONTRACTOR SHALL BE RESPONSIBLE FOR ( 11 SAS _ DB_ 4$ �� DETERMINING THE LOCATION OF ALL UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO ` / {a�i9) I COMMENCEMENT OF ANY WORK. THIS INCLUDES, BUT IS NOT LIMITED TO, REQUESTS TO DIGSAFE, ' ' (49.4) �j�o lExcavation45 44 I10 ANY PRIVATE UTILITY COMPANIES, AND THE LOCAL WATER DEPARTMENT. / �`` �.1 N,N I Notes o i' �12'� I See Note / exec S_Tonk + { �,s I 16.) CONTRACTOR SHALL VERIFY THAT ALL WASTELINES ARE CONNECTED BY WATER TESTING z #19 / e i WITHIN THE DWELLING PRIOR TO INSTALLATION OF ANY SEPTIC COMPONENTS. r,,; / (49.7) k41.4) 17.) CONTRACTOR SHALL VERIFY EXISTING INVERT ELEVATIONS PRIOR TO INSTALLATION OF ANY o ;(5t.o) / I I I {4s.�) - Fence (4a1 44 - 42 t- SEPTIC SYSTEM COMPONENTS. Assessors Ma 50 C C // 1 45 C) (IP to 18.) TEST HOLES COMPLETED PER STATE ENVIRONMENTAL CODE, TITLE 5, SOILS CAN BE Parcel 53p * / House 12 48 1 o - VARIABLE AND TEST HOLE DATA IS NO GUARANTEE OF SOIL CONDITIONS IN OTHER AREAS. IF 50 ' # ` o 3 Bedroom SOILS DIFFER FROM THOSE SHOWN IN THE SOILS LOGS, DESIGN ENGINEER IS TO INSPECT THE ' TOF = 50 0 {45,T SYSTEM DESIGN CALCULATIONS SEWAGE DESIGN FLOW REQUIRED: 3 BEDROOM DWELLING @ 110 GPD / BEDROOM = 330 GPD REQUIRED SEWAGE DESIGN FLOW PROVIDED: THREE (3) H2O 500 GALLON LEACH CHAMBERS WITH 2' STONE ON THE ENDS AND 2.5' STONE ON THE SIDES Vt = [(29.5 x 9.83) + 2(29.5 + 9.83) (2) x .74 = 331 GPD PROVIDED 331 GPD PROVIDED > 330--GPD REQUIRED SEPTIC TANK CAPACITY REQUIRED: 330 GPD X 200 SEPTIC TANK CAPACITY PROVIDED: EXISTING 1,000 GALLON SEPIC TANK TO REMAIN A GARBAGE DISPOSAL IS NOT PERMITTED WITH THIS DESIGN FLOW 29.5' 2'�8.5' TBM EL = 49.5 I �s�� V Top Bulkhead Corner _ 10 ov _ N 3 c THREE 3 H2O 500 GALLON CHAMBERS.' s 0 Co (J}y 't Assessors Mop 50� SOILS PRIOR TO PROCEEDING WITH INSTALLATION OF ANY SEPTIC COMPONENTS. f _ 1 Parcel 55 ��' N 19.) EXISTING SEPTIC COMPONENTS TO BE LOCATED, PUMPED DRY, FILLED WITH CLEAN SAND AND 1 Paved I (45.3) 46 ABANDONED IN PLACE OR REMOVED AS REQUIRED. AREA TO BE COMPACTED TO MINIMIZE SETTLING. 1 Driveway }ec -rr�r i 1�1 r- I 1�% /_,�r-+ Test Hole #1 (EL=43.7±) I LJ I I I VLL- LvvJ Depth Elev. Layer Soil Class Soil Color Comments 0"-12" 42.7 A Loamy Sand 1OYR 3/2 12"-36" 40.7 B Loamy Mediurn 1OYR 5/6 Fine Sand 36"-108' 34.6 C Medium Fine 2,5Y 6/6 Sand ENCOUNTERED GROUND WATER @ 92" EL = 36.0 DATE OF TESTING: 1/17/19 SOIL EVALUATOR: DAN CROTEAU BOARD OF HEALTH AGENT: AMY von HONE PERCOLATION RATE: LESS THAN 2 MIN/INCH (C Layer) AT 39" Enclosed Kitchen Porch Living Room Both I Bedroom #1 Bedroom Bedr( #3 1 #2 1st Floor Plan N. T. S. EXCAVATION NOTES 1) EXCAVATE ALL MATERIAL ABOVE SOIL HORIZON C SEE DEEP OBSERVATION HOLE LOG) AT AN APPROXIMATE DEPTH OF 36", FOR A LATERAL DISTANCE OF 5' (WHERE POSSIBLE) IN ALL DIRECTIONS BEYOND THE OUTER PERIMETER OF THE LEACHING AREA. 2) FILL MATERIAL SHALL CONSIST OF CLEAN GRANULAR SAND, FREE FROM ORGANIC MATTER AND OTHER DELETERIOUS SUBSTANCES, WHICH MEETS THE TEXTURAL CRITERIA PUT FORTH IN SECTION 15.255(3) OF TITLE 5. 3) SCARIFY THE BOTTOM SURFACE OF THE EXCAVATION PRIOR TO PLACEMENT OF FILL INTO THE RETAINING STRUCTURE. 4) PLACE FILL ONLY WHEN BOTTOM SURFACE IS DRY. 2 Lot 9 11,000± Sq. Ft. I / 1 1 exec I � 1 I 1 110.00' 1 S 86'38'10" W Saturn Lane 40' Public Way GRAPHIC SCALE ( IN FEET ) 1 inch = 20 ft. H OF Mgss . DANIEL s P. a' o CROTEAU U CIVIL in No.46253 P�t -PF(`' I S T 0' �SS/ONAL �G ✓% , /.. OF Mgss9 o STEPPHEN �G B. rn o MOORE -4 cN�o.39398 SO D-Box VARIANCE REQUESTED Permit valid for REPAIR 0F SEPTIC SYS'I'H:1 ONLY,, due to State and I t,cal septic. variance! Board of Flealth review and approval is retluire(f do any future adtltions/rennkations/aIterations t sewage facilities and/or structu+es/dwelling. Local Upgrade Approvals: 310 CMR 15.403 l'`rntotath Nrtlth llclrt►tment Variances: 310 CMR 15.211(7) General Constructio Requirements for All System Components: AP) ����.1', 9 VIJ)� 0, c 1•) Soil Absorption System >36" Below Finish 54" Held 18" Variance Requested Ground ( Not to Exceed 72" (H20 Chambers to be installed) - .�- Ta to bate Note: This plan is only valid for current regulations and may not be suitable for future regulation changes that may occur. r Proposed Sewage Disposal System 12 Saturn Lane South Yarmouth, MA ' Prepared by: Prepared for: ' Felipe Fischer All Cape Septic LLC 12 Saturn Lane 618 Route 28 South Yarmouth, MA West Yarmouth, MA 02673 (508) 771-4200 all copeseptic@gmoil. corn Date: 1/23/19 Sheet 1 of 1 1 By: MA Check: SM I Project No. AC-165