Loading...
HomeMy WebLinkAboutEngineered Plan - 2019NKEY: 4 EXISTING CONTOUR: - — — - PROPOSED CONTOUR: ............. EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 QUARTERMASTER TEST HOLE: t ROW UTILITY POLE: -O- FENCE LINE: WINDJAMMER LN HYDRANT: -.- RETAINING WALL: CAPT RYDER RD II LOCUS LOCATION MAP LOT 89 (14,875 SF) ASSESSORS MAP: 77 PARCEL: 107 PLAN BOOK: 250, PAGE: 139 M18-82 24.0' 0 LEACH AREA DETAIL ---100 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 2 BEDROOMS AT 110 GAL / DAY = 220 GAL / DAY SEPTIC TANK: 220 GAL / DAY x 2 DAYS = 440 GAL USE 1000 GALLON SEPTIC TANK (EXISTING) LEACHING AREA: USE 2 FLOWDIFFUSORS WITH 4' OF STONE ALL AROUND (24'x 12'x 11" EFFECTIVE DEPTH SIDE AREA: (24' + 12') x 2 x 11/12 = 66 SF (0.74) =.j9 GAUDAY BOTTOM AREA: 24'x 12'= 288 SF (0.74) =213 GAL/DAY CAPACITY = 262 GAUDAY MSR 102 , v� - 102 GARAGE SEPTIC SYSTEM SECTION 104.53 COVERS WITHIN 6" TOP OF OF FINISHED GRADE ,, FOUNDATION 101.36/a 1/8" per ft ELEV. 100,95 (EXISTING) ELEV. 1 01.2 ELEV. 1000 GAL SEPTIC TANK T MAX. COVER (V MIN) 1/8" per ft -�v• GLG V. D -BOX (6" STONE UNDER) TEE SIZES: (TO BE CONFIRMED) ELEV. INLET: 6" UP 13" DOWN GAS BAFFLE OUTLET: 6" OP, 14" DOWN AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, RE, WITNESS: AMY VON HONE, R.S. LIVING CLOS. BED DATE: 1-10-19 ROOM ROOM BATH PERCOLATION RATE: <2 MIN/IN DINING I BED I ROOM ROOM BATH KITCHEN SH DECK L—JEE3 EXISTING FLOOR PLAN F rmouth Healtli (Department P �VED m (Date BENCHMARK AT RIGHT CORNER OF TOP CONC. STEP ELEVATION = 104.87 MAR 19 2019 HEALTH DEPT. �j va��tN OF MAS;N � TERRY o ANN in " WARNER ), No. 38721 s: USGS GROUND WATER ADJUSTMENT: WELL: AIW-230, ZONE: B, ADJ. (DEC.): 0.1' ADJUSTED GROUND WATER ELEV.= 94.6 2" PEASTONE OR FILTER FABRIC - 3/4" - 1 1/2" DOUBLE WASHED STONE INSPECTION PORT r- ELEV.= 101.16 1,1=1 11 . "°"°"°°"°°"1'1 9966 <-> 4 ELEV. F 24'x 12' 2 FLOWDIFFUSORS WITH 5.06' 4' OF STONE ALL AROUND (24'x 12'x 11" DEEP) ADJUSTED GROUND WATER ELEVATION = 94,6 TH-1 FILL LOAMY SAND 1 OYR 3/3 99..5 B HORIZON LOAMY SAND 1 OYR 5/8 98.5 C HORIZON MEDIUM SAND 2.5Y 7/4 FERC AT 48" 120"1 GROUNDWATER NOTES: 1, VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 --4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/8" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. I 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS, 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING LEACH PIT IS TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 15, ALL UNSUITABLE SOIL (FILL, A & B HORIZON, APPROX. 42" DEEP) WITHIN 5' OF PROPOSED LEACH AREA IS TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND. 16.2 BEDROOM DEED RESTRICTION TO BE FILED AT REGISTRY OF DEEDS PRIOR TO CONSTRUCTION. D,10149p,SJ. ftL ELLN4 1>1VI1.. NO. 336471 SITE PLAN LOCATION: 65 WINDJAMMER IN., S. YARMOUTH, MA PREPARED FOR: CECILE WILHELMI DATE: 1-14-19 SCALE: 1" = 20' BASS RIVER ENGINEERING TIOMAS J. McLELLAN, P.E. P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048 y, E.r a CD 0 -o 04 S 2 C o_ 0 r� Z m M18-82 24.0' 0 LEACH AREA DETAIL ---100 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 2 BEDROOMS AT 110 GAL / DAY = 220 GAL / DAY SEPTIC TANK: 220 GAL / DAY x 2 DAYS = 440 GAL USE 1000 GALLON SEPTIC TANK (EXISTING) LEACHING AREA: USE 2 FLOWDIFFUSORS WITH 4' OF STONE ALL AROUND (24'x 12'x 11" EFFECTIVE DEPTH SIDE AREA: (24' + 12') x 2 x 11/12 = 66 SF (0.74) =.j9 GAUDAY BOTTOM AREA: 24'x 12'= 288 SF (0.74) =213 GAL/DAY CAPACITY = 262 GAUDAY MSR 102 , v� - 102 GARAGE SEPTIC SYSTEM SECTION 104.53 COVERS WITHIN 6" TOP OF OF FINISHED GRADE ,, FOUNDATION 101.36/a 1/8" per ft ELEV. 100,95 (EXISTING) ELEV. 1 01.2 ELEV. 1000 GAL SEPTIC TANK T MAX. COVER (V MIN) 1/8" per ft -�v• GLG V. D -BOX (6" STONE UNDER) TEE SIZES: (TO BE CONFIRMED) ELEV. INLET: 6" UP 13" DOWN GAS BAFFLE OUTLET: 6" OP, 14" DOWN AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, RE, WITNESS: AMY VON HONE, R.S. LIVING CLOS. BED DATE: 1-10-19 ROOM ROOM BATH PERCOLATION RATE: <2 MIN/IN DINING I BED I ROOM ROOM BATH KITCHEN SH DECK L—JEE3 EXISTING FLOOR PLAN F rmouth Healtli (Department P �VED m (Date BENCHMARK AT RIGHT CORNER OF TOP CONC. STEP ELEVATION = 104.87 MAR 19 2019 HEALTH DEPT. �j va��tN OF MAS;N � TERRY o ANN in " WARNER ), No. 38721 s: USGS GROUND WATER ADJUSTMENT: WELL: AIW-230, ZONE: B, ADJ. (DEC.): 0.1' ADJUSTED GROUND WATER ELEV.= 94.6 2" PEASTONE OR FILTER FABRIC - 3/4" - 1 1/2" DOUBLE WASHED STONE INSPECTION PORT r- ELEV.= 101.16 1,1=1 11 . "°"°"°°"°°"1'1 9966 <-> 4 ELEV. F 24'x 12' 2 FLOWDIFFUSORS WITH 5.06' 4' OF STONE ALL AROUND (24'x 12'x 11" DEEP) ADJUSTED GROUND WATER ELEVATION = 94,6 TH-1 FILL LOAMY SAND 1 OYR 3/3 99..5 B HORIZON LOAMY SAND 1 OYR 5/8 98.5 C HORIZON MEDIUM SAND 2.5Y 7/4 FERC AT 48" 120"1 GROUNDWATER NOTES: 1, VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 --4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/8" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. I 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS, 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING LEACH PIT IS TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 15, ALL UNSUITABLE SOIL (FILL, A & B HORIZON, APPROX. 42" DEEP) WITHIN 5' OF PROPOSED LEACH AREA IS TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND. 16.2 BEDROOM DEED RESTRICTION TO BE FILED AT REGISTRY OF DEEDS PRIOR TO CONSTRUCTION. D,10149p,SJ. ftL ELLN4 1>1VI1.. NO. 336471 SITE PLAN LOCATION: 65 WINDJAMMER IN., S. YARMOUTH, MA PREPARED FOR: CECILE WILHELMI DATE: 1-14-19 SCALE: 1" = 20' BASS RIVER ENGINEERING TIOMAS J. McLELLAN, P.E. P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048