Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 2019Q Q 00 Ln O z CL N /F EVANS N/F MORELLO S 821015Q„ E xsi442' Ia,o r ; ° C + 13,71 '_LOT 4x 13,5im il IM 14.4 x 13.9T< 215O.- 8.4. I LOCATED IN WOODS --TRENCHES (• I t MAY BE MOVED TOWARDS CENTER x 13.4 OF LOT TO AVOID TREES. L x 13.2 •13,1 / I TH 1 I / N / F x 12.7 / I x 12.5 Iz SKORDAS / / IW Z LU o� O to Oct C 11.5 x 119 /^ I _D g- BENCH MARK --TOP BACK, CENTER 4 Z. // 10 41 SEPTIC TANK=11.91 ASSIGNED C1qI ALARM & PUMP NOTES 1. ALARM TO BE WIRED BY ELECTRICIAN ON SEPARATE CIRCUIT FROM PUMP. 2. ELEQTRICAL WORK TO BE INSPECTED BY WIRING INSPECTOR. 3. PUMP TO BE CAPABLE OF PASSING 1-1/4" SOLIDS AND INSTALLED IN STRICT CONFORMANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. USE MEYER 'SRM4, 4/19 HP PUMP, OR EQUIVALENT, 5. TO PROVIDE FOR EASY AND SAFE MAINTENANCE OF PUMP: . PROVIDE UNION/DISCONNECT IN 2" PVC 'LINE AT TOP PUMP CHAMBER SO PUMP CAN BE REMOVED FROM OUTSIDE. . PEGOMMEND FLOATS BE ATTACHED TO 2" PUMP LINE SO FLOATS CAN BE ADJUSTED OUTSIDE -CHAMBER ALSO. LEGEND TH 1 TEST HOLE LOCATION, NUMBER W WATER LINE MEASURED IN BASEMENT GAS: LINE FLAGS E OVERHEAD EI ECTRIQ WIRES (IF SHOWN) x 9.5 x 9.5 EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT) EXISTING CONTOUR g----- PROPOSED CONTOUR UTILITY POLE (IF SHOWN) REV.:2/7/19--PUMP CHAMBER & LEACHING z / � I x 12.6 13.9 12. x 12.4 I x 12.1 �J I a� 1ZL 12A2.8 I x 10.7 x ox a 7 I. �i 1 12.9 I x 13.5 cV 1 I x 14.3 I Exist. i . I J,9 x 11.5 r 1 ,71�1,81 Deck i I x 11,5 ::......... .. .............. I x 2.1 ..........�.....�........ i I - 13.5 EXISTING HOUSE X I x 1 .7 N0. 154 + 12.29 x 15,4 I 12.25 Y t � I ::...A ::......... Q :. ell 13.4 1' 13.61 13,54 x 15.1 / x 12.9 1 13,1 1 13,49 i x 3.8 F, 1 N I /7 I 12�6 7 1 ::D I 2 7.48' x I j j 12.110 x 12.1 N 82'S7'0Q„ W 11,8 t? j a i i x 15.1 A=9,6 00' j R=6019. 77' Edge ap paVement --� 12.20 `-1�,4�--L---------- 13,7( CAP T SMAL L ROAD 1000 GALLON H-10 PUMP CHAMBER MAKE WATER TIGHT Cover to grade DRILL 3/8" WEEP/VENT HOLE Recommend Floats replaceable from top Quick Disconnect/ 10.55 larrn 32" Union Invert On 26" Check Valve Off 2"' 8 05 P 11 5.97STONE UNDER Bottom MAXIMUM FEASIBLE COMPLIANCE AQPROVALS• 1. VARY DEPTH TO GROUNDWATER BY 1'. 310 CMR 15.212 1 ( N /F CHESTNUT BENCH MARK --TOP SPIKE SET I DOWN 1" =12.45 ASSIGNED (44'-2" OFF HOUSE CORN., 5' OFF RANGE LINE) JOB NO. Y18-- 22 NOTES Kelly.dwg Old Towne House Rd. ---- 1. LOCUS IS AM.. 77, PARCEL 35. FB 33/79 SB 14/50 2. ELEVATIONS SHOWN ARE ASSIGNED. -o 3. LOCUS IS IN FLOOD ZONE X (<0.2% RISK) 'ON FIRM DATED JULY 16, 2014. 4. ALL PIPES TO BE 4" SCH 40, AND PITCHED AT ' 1 /4" PER FOOT. (UNLESS in 5. ,NOTED) MUNICIPAL WATER IS AVAILABLE. LOTS. WITHIN 100' ARE ON TOWN WATER. 6. COMPONENTS TO BE AASHTO H-10, UNLESS NOTED. 7. INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14". 8. IF TWO OR MORE LINES, -WATER TEST D-BOX FOR EQUAL FLOW Cpt. Small Rd,. D-BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. 9. DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED. af NOT TO COVERS TO GRADE--1 ON TANK, 1 OVER PUMP ---BUILT UP COVERS; 2 ON :LEACH, D--BOX. SCALE 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1 /2" WITH 2" MIN. 1 /8 TO 1 /2" PEA STONE ON TOP. LOCATION MAP 11. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. 12. IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). TEST HOLE 1 13. PUMP AND FILL ANY EXISTING CESSPOOLS. REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT. DEPTH (inches) ELEV.(feet) 14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. 131 BATH I BDRM BATH KIT DNRM J -[ GAR LIVRM BDRM BDRM EXISTING FLOOR PLAN NOT TO SCALE BASEMENT UNFINISHED i 14.48f Top of Found. 4.8 Septic Tank 3.1 ,Existing ---------- ---- Sanitary 3.8" ' 6.6 Tee T Bottom Invert 12.10 11.55 I Invert 11.87 a 6" Stone or compact Proposed Proposed 4 Bottom level ' -� 3.5'1 1 63'i i N i-- ,---+ High Water=7.55(2/7/19) I 5 High Ground Water=5.9 DESIGN DATA 1.1' USGS Adjustment AlW-230 October 2018 BEDROOMS: 3 ;' Zone B/C Line GARBAGE GRINDER: No Observed Water=4.8 REQUIRED CAPACITY: 330 GPD z �- PROPOSED SEPTIC TANK: 1500 GAL. LEACH AREA EFFECTIVE LEACHING AREA: 463.2 SF 5.79 SF/LF X 5/UNIT=28.95 S.F/UNIT - USE TWO ROWS OF TRENCHES, AS SHOWN, 16 UNITS X 28.95 SF/UNIT=463.2 SF(EFFECTIVE) EACH BEING 34" X 40' X 3.6" DEEP. DESIGN CAPACITY: 342.7 GPD [(463.2 SF) X .74 GPD/SF] PUMP CHAMBER STORAGE CAPACITY: 330 GAL. DOSES PER DAY: 3.9, BUQYANCY CALQ'S-1000 GALLON PUMP CHAMBER WEIGHT OF EMPTY CHAMBER AND AVERAGE 9" COVER CHAMBER= 4.15 TON (PER ACME-SHOREY) 9" COVER= .75' X 4.83' X 8.5' X 0.055 TON/CU. FT. 9" COVER=1.69 TON Permit valid for ItF:PAtIt OF SI?I'"IIC Sl'SI1?Ri TOTAL- 4.15 TON + 1.69 TON = 5,84 TON ONI,V, due to state and Local septic variances. WEIGHT OF WATER --HIGH GROUNDWATER DOWN Board of Ilealth review and approval is 1eyuircd for (,7.55 -5.97) X 4.83 X 8.5 X 0.0312 TON/CU. FT. ally futgi-c additions/reuovationzhilterations to WEIGHT WATER= 2.02 TON sewage facilities an'(!/or strucimes/dsvclhng. TANK AND 9" COVER ARE HEAVIER BY 3.8 TON. yr:mouth licalth 1)tl>arfnient APPR0 V E, /cJ I Name Date i; SITE PLAN FOR THIS PLAN IS A VALID COPY ONLY IF IT BEARS AN ORIGIN L RED STAMP ND SIGNATURE. ROBERT Vo & KAREN R. KELLY OFXq r OFA LOT 4 154 CAPT. SMALL RD S. YA .tt5A OF MAgs9c.. ' l�tass4e. , , R M 0 U TH RONALD s ' �RONALD s � i� , 4;o JAMES �,'o JAMES,, N 0 V EMBER .J, 2018 SCALE. 1 --20 CADILLAC �' ' " CADILLAC # 1060+, �, # 35779 A a o �y FQ/STEQO '.��q �ESS�O 0 0 9" TEST HOLE DATE: November 1, 2018 USE SLIGHT GRADE PERFORMED BY: Ron Cadillac, Soil Evaluator 16„ CHANGES, AS SHOWN WITNESSED BY: Philip Renaud, Inspector Iac)L PERC RATE: <2 --00 /Inch (B' layer) 2911 SOIL SURVEY(1993): Carver coarse sand 48"' GEOLOGIC MAP(1986): Harwich outwash plain deposits Invert 11.70± Proposed REPLUMB Invert 10.59 16--ARC 36LP (3.8") Use Gas Baffle Cover t0 grade Effluent Filter 2 TRENCHES W/O STONE Invert 11.93 Provide 1' Cover S=5/8"/ft 6" cover see detail Proposed Top Units=12.22 .0 Filter Cloth Existing 3" Max. 100" Invert 11.11 1000 Gal. P -c Inspection Port 120" HEALTH AGENT APPROVAL DATE Fill A/E layer 10yr 5/4 loamy sand B layer 10yr 5/8 loomy .sand C layer 2.5y 6/4 medium sand _- observed water - RONALD J. CADILLAC, PLS, IRS PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 (508) 775-9700 )2018 BY R.J..�CADILLAC PAGE 1 OF 1