Loading...
HomeMy WebLinkAboutReview Checklist 2-1---(f TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST c� R Location: A.M. Lot 9t Zone of Contribution: In Out `- Acreage /' Commercial: Residential: L---•Street: / d� /L�%� Village: C />., Floor Plan: ,.. #Bedrooms: Owner: j C67 Installer: A( ( F. Address: Phone: c• - 7 7 -- f Phone:Builder: Engineer: A171)e ---- ‘t4>Address: 7.------- Phone: P _ 7 7/ )4e Phone: i 41 /k, / .67//c A YES NO 1.Required#of copies received L`" 2.Date of soils exam and percolation test not older than 2 years l...- - 3. 4-5 ft of naturally occurring pervious material, above water table (....---- 4. /4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: (...------- 6.Benchmark indicated and shown-NGVD if near wetlands L.....--- 7. Septic tank minimum 10 ft from foundation, deck Var.: A-_---- 8. ./8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: t...----- 9. .S9.Leaching minimum 100 ft from wetlands Var.: L� 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: _ 11.Tank/leaching minimum 10 ft from property line Var.: L----- 12. 112. System meets all other setback requirements Var.: C.----• 13.Uses adjustment for maximum high groundwater Var.: �--- 14. Leaching set 4-5 ft above adj.water or bott of test Var.: 15. System not in top or subsoil(A,B horizons)or 5' remov L/ 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", 1/4"preferred C------ 18. .-/18. System meets breakout requirements PVC liner: Wall: L.--- 19. Specified tee sizes are proper, gas baffle on outlet tee L._® 20. Sewage is under 10,000 gpd for parcel `---• 21.No garbage disposal 22. System adequately sized for its intended use �---- 23.Minimum 6"stone or compacted below tank and dbox ‘� �24.Manhole covers within 6"of grade,pump chamber cover to grade 25. Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed ------' 29. Vent provided if leaching below 3 feet,under driveway/parking ------- 30. Buoyancy calculations for tank/pump chamber ---P'" 31. Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33. H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee, installer signature • --..--- 35.Foundation footing min. 2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map ..----- Plan reviewed by: 6/03/03