Loading...
HomeMy WebLinkAboutReview Checklist t 1 f r-6 TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST i Location: A.M. /5 / Lot 2 c Zone of Contribution: In Outer Acreage Commercial: Residential: L/ Street: 2 7 1.1% Village: (,� Floor Plan: t___ #Bedrooms: Owner: Z.-(52,(:, .42tt' Installer: (Gz �C. "(1.7160:4424.44- Address: - " Phone: -9 - -- /.( Phone: Builder: Engineer: i �fi�,' r G4i/ Address: Phone: �5 Phone: / w/I :f 7/ .y;/ /-/<.-/ 5 N/A YES NO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years ‘..---- 3.4-5 „o3.4-5 ft of naturally occurring pervious material, above water table k 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: t___-- 5. Water line 10 ft from septic components Var.: 6.Benchmark indicated and shown-NGVD if near wetlands L..--'-- 7. Septic tank minimum 10 ft from foundation, deck Var.: , ,--- 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ,-._.- 9.Leaching minimum 100 ft from wetlands Var.: - 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: (I- 11.Tank/leaching minimum 10 ft from property line Var.: ___ 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: .,__..- ,. 14.Leaching set 4-5 ft above adj. water or botto o test hole Var. 15. System not in top or subsoil(A,B horizons r 5_'removal 16.Proposed contours are suitable L ._._.- 17. System meets slope requirements-min. 1/8", '/4"preferred L.------ 18. - -'18. System meets breakout requirements PVC liner (Nall: ( _�- 19. Specified tee sizes are proper, gas baffle on outlet tee �- 20. Sewage is under 10,000 gpd for parcel ..--" - 21.No garbage disposal ,...•..%---- 22. System adequately sized for its intended use (..--- 23. "- 23.Minimum 6"stone or compacted below tank and dbox ti - 24.Manhole covers within 6"of grade,pump chamber cover to grade t 25.Inspection port on plastic chambers/leach field -- 26.Electrical permit for pump chamber/Separate meter for duplexes ---- 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size --- 28. Septic tank/pump chamber to be factory waterproofed ------ ,.., 29. Vent provided if leaching below 3 feet, under driveway/parking _) 30. Buoyancy calculations for tank/pump chamber t 31.Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature �_____- 33. H-20 loading is subject to vehicular traffic, groundwater 34. Title V Application and permit fee, installer signature \35.Foundation footing min. 2 feet above adjusted ground water for new house ------- 36. -----36.Deed Restriction required max. #bedrooms: max. flow: gpd -- 37.Check area lots for groundwater/Label groundwater in Assessor's Ma Plan reviewed by: �.,-� 6/03/03