Loading...
HomeMy WebLinkAboutReview Checklist / 7(F TOWN OF YARMOUTH , �j SEWAGE PLAN REVIEW CHECKLIST Location: A.M. / 7 Lot C//1, Zone of Contribution: In Out e/ Acreage Wil Commercial: Residential: ✓---�Street:::V k7�G�LCGC (c ' / Village: Floor Plan: #Bedrooms: &--1--:) Owner: /4 7 ' /01(443.7 7 (.*f Installer: Address: ` Phone: . q7 7 7 7 Phone: Builder: Engineer: /%(1 C // (\4 ›, Address: Phone: S'7lsc- - 3c-6 Phone: = '�-<' cc 'r' b- .` _.- L L ' k - et,e•464'4 (59.0I' i '?cdCleri 1.Required#of copies received _-------- 2.Date of soils exam and percolation test not older than 2 years C_.------_ 3.4-5 ft of naturally occurring pervious material, above water table (, <- 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: <____.------ 5. 5.Water line 10 ft from septic components Var.: L-� 6.Benchmark indicated and shown-NGVD if near wetlands c.----- 7. Septic tank minimum 10 ft from foundation, deck Var.: '`s..._..--, 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ..------ 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: , 13.Uses adjustment for maximum high groundwater Var.: L__-- 14.Leaching set 4-5 ft above adj.water or bottom est Iiol ,Var.: -- 15.System not in top or subsoil(A,B horizons) o 5' e-----'ec _ 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", '/4"preferred C.----- 18. .18. System meets breakout requirements PVC liner: Wall: " 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel - 21.No garbage disposal ._. 22. System adequately sized for its intended use ..� 23.Minimum 6"stone or compacted below tank and dbox _ 24.Manhole covers within 6"of grade, pump chamber cover to grade 25.Inspection port on plastic chambers/leach field -�/ 26.Electrical permit for pump chamber/Separate meter for duplexes C 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet,under driveway/parking --- 30. Buoyancy calculations for tank/pump chamber ,-/- 31.Engineer to inspect and certify soils: wall: commercial:t___,...-^ 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature _f/ 33.H-20 loading is subject to vehicular traffic, groundwater t.._...--- _ 34. Title V Application and permit fee, installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: P./ 6/03/03