HomeMy WebLinkAboutReview Checklist / 7(F TOWN OF YARMOUTH ,
�j SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. / 7 Lot C//1, Zone of Contribution: In Out e/ Acreage
Wil Commercial: Residential: ✓---�Street:::V k7�G�LCGC (c ' /
Village: Floor Plan: #Bedrooms: &--1--:)
Owner: /4 7 ' /01(443.7 7 (.*f Installer:
Address: ` Phone: . q7 7 7 7
Phone:
Builder: Engineer: /%(1 C // (\4 ›,
Address: Phone: S'7lsc- - 3c-6
Phone: = '�-<' cc 'r' b- .` _.- L L ' k
- et,e•464'4 (59.0I' i '?cdCleri
1.Required#of copies received _--------
2.Date of soils exam and percolation test not older than 2 years C_.------_
3.4-5 ft of naturally occurring pervious material, above water table (, <-
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: <____.------
5.
5.Water line 10 ft from septic components Var.: L-�
6.Benchmark indicated and shown-NGVD if near wetlands c.-----
7. Septic tank minimum 10 ft from foundation, deck Var.: '`s..._..--,
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ..------
9.Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11. Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.: ,
13.Uses adjustment for maximum high groundwater Var.: L__--
14.Leaching set 4-5 ft above adj.water or bottom est Iiol ,Var.: --
15.System not in top or subsoil(A,B horizons) o 5' e-----'ec _
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", '/4"preferred C.-----
18.
.18. System meets breakout requirements PVC liner: Wall: "
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel -
21.No garbage disposal ._.
22. System adequately sized for its intended use ..�
23.Minimum 6"stone or compacted below tank and dbox _
24.Manhole covers within 6"of grade, pump chamber cover to grade
25.Inspection port on plastic chambers/leach field -�/
26.Electrical permit for pump chamber/Separate meter for duplexes C
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed
29.Vent provided if leaching below 3 feet,under driveway/parking ---
30. Buoyancy calculations for tank/pump chamber ,-/-
31.Engineer to inspect and certify soils: wall: commercial:t___,...-^
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature _f/
33.H-20 loading is subject to vehicular traffic, groundwater t.._...--- _
34. Title V Application and permit fee, installer signature
35.Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: P./ 6/03/03