HomeMy WebLinkAboutReview Checklist t )--g' (7
TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. 9. Lot 1. s Zone of Contribution: In Ou eage
r -4 / �� .� Commercial: Residential-f''
Street: / /
Village: eTtafij Floor Plan: C ---,""'l_ #Bedrooms:_.
Owner: 0 5 Installer: 5 'fir/'
Address: Phone: QV -ic, 'O'C/2--
Phone:
Builder: Engineer: Aq
Address: Z-- Phone: ,-/ -"� - '�&4
Phone: / 5e r 634Vidiihe,fr 3-4Va4V
N/A YES NO _
1.Required#of copies received
2. Date of soils exam and percolation test not older than 2 years (..-----
3.4-5
-----3.4-5 ft of naturally occurring pervious material, above water table `---''
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: v..-----
5.
i"5. Water line 10 ft from septic components Var.: L.--.a-
6. Benchmark indicated and shown-NGVD if near wetlands L.....----"
7. Septic tank minimum 10 ft from foundation, deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: h', �� ��
9.Leaching minimum 100 ft from wetlands Var.: L------
10.
!10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: C
11. Tank/leaching minimum 10 ft from property line Var.: /,C'- (_,-
12. System meets all other setback requirements Var.:
13.Uses adjustment for maximum high groundwater Var.: 0,?c, OOP �o
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.:
15. System not in top or subsoil(A,B horizons)or 5' removal 1/4----
16.Proposed contours are suitable %.........-----
17.
,/17. System meets slope requirements-min. 1/8", I/4"preferred C..------
18.
/18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee .,----
20. Sewage is under 10,000 gpd for parcel c_...----
. 21.No garbage disposal C.----'
22. System adequately sized for its intended use c..®--
23.Minimum 6"stone or compacted below tank and dbox L.------
/2524.Manhole covers within 6"of grade,pump chamber cover to grade LA-------
25.
.Inspection port on plastic chambers/leach field L,....------
26.
!26.Electrical permit for pump chamber/Separate meter for duplexes ...---"
27.Pump system-2" line,weep hole,check valve,tee in dbox, pump size i.®"'
28. Septic tank/pump chamber to be factory waterproofed ...-------
29.Vent provided if leaching below 3 feet,under driveway/parking ..-------"
30.Buoyancy calculations for tank/pump chamber ./.
31.Engineer to inspect and certify soils: wall: commercial: ,/'
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33. H-20 loading is subject to vehicular traffic, groundwater
34.Title V Application and permit fee, installer signature -
35.Foundation footing min. 2 feet above adjusted ground water for new house ..../-
36.
36.Deed Restriction required max. #bedrooms: max. flow: gpd /-
37.Check area lots for groundwater/Label groundwater in Assessor's Map ..--- -
Plan reviewed by: �.! 6/03/03