HomeMy WebLinkAboutReview Checklist 1�� / �� TOWN OF YARMOUTH /'C
SEWAGE PLAN REVIEW CHECKLIST (r� 1---"-
'
Location: A.M. 6 Lot ('P Zone of Contribution: In Out acreage ,
\ ��jA A � !'�� �� n Commercial: �- Residential:
Street: > C ���_III F
Village: /PG 1 Floor Plan: 7 V #,Bedrooms:
Owner:7-4j 41(5-
41-4 L((Installer: ' /,, _ f -
Address: Phone: &- 41 j ..... 7/SI
Phone: c: ° ,/
Builder: Engineer: ag /(
Z(///e-Ci
Address: Phone: 5-'3/3
Phone: / -ft?
N/A YES NO
1.Required#of copies received L--'
2.Date of soils exam and percolation test not older than 2 years
3.4-5 ft of naturally occurring pervious material, above water table _
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ,�y
5.Water line 10 ft from septic components Var.:
6.Benchmark indicated and shown-NGVD if near wetlands i ---
7. Septic tank minimum 10 ft from foundation, deck Var.: c -_
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: (....-
9.Leaching minimum 100 ft from wetlands Var.: ---
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: `
11.Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.: ,,.-__-
13.Uses adjustment for maximum high groundwater Var.: � _
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: l
15. System not in top or subsoil(A,B horizons)or 5'removal k,----
16.
.-- -16.Proposed contours are suitable k---
17. System meets slope requirements-min. 1/8", 1/4"preferred -
18. System meets breakout requirements PVC liner: all:
,
19. Specified tee sizes are proper, gas baffle on outlet tee 7 ,4---e/ 7k, -j y-"'
I �
• 20. Sewage is under 10,000 gpd for parcel i_,-.
21.No garbage disposal ..
22. System adequately sized for its intended use
' 23.Minimum 6"stone or compacted below tank and dbox L
24.Manhole covers within 6"of grade,pump chamber cover to grade
25.Inspection port on plastic chambers/leach field
26.Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2" line,weep hole,check valve,tee in dbox, pump size _
28. Septic tank/pump chamber to be factory waterproofed ,,___
29.Vent provided if leaching below 3 feet,under driveway/parking _
30. Buoyancy calculations for tank/pump chamber -
31. Engineer to inspect and certify soils: wall: commercial: k______-----
32.
__,�32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature ,--
33.H-20 loading is subject to vehicular traffic, groundwater
..----
34.
�34. Title V Application and permit fee, installer signature ( _
35.Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd - -_.
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: 6103/03