GENERAL NOTES:
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW:
—310 CMR 15.405(1)(b): LOCAL UPGRADE APPROVAL
1) A 3' variance to the 3' maximum cover requirement, for up to
6' of max. cover. S.A.S. shall be H-20 and vented.
—310 CMR 15.223(1)(b): SEPTIC TANKS
2) A variance to waive the requirement of a two compartment tank
for a facility other than a single family unit.
—310 CMR 15.254(2): PRESSURE DISTRIBUTION
3) A variance to waive the requirement of pressure distribution for
the subject septic system although the aggregate flow for the
facility exceeds 2000 GPD.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S.
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
DIRECTED BY THE APPROVING AUTHORITIES.
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL.
13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND
NOT CONSIDERED TO BE A PROPERTY LINE SURVEY.
14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC
SYSTEM COMPONENTS NOT SHOWN ON THE PLAN
PLAN REVISION — 1/16/19 OWNER OF RECORD
ADD VARIANCE REQUESTS 2 & 3 1261 BASS RIVER REALTY LLC
7 CENTRAL STREET
SOUTH EASTON, MA 02375
LOCUS MAP
NOT TO SCALE
I
O �
62
s
o�
i
�o ss
PUMP HOUSE
El
CL -
20
20 SCALE WINDOW
SEE SHEET 2 �.
102,796±S.F.
2.36±Ac.
PARCEL ID: 60-196
Perm:v,,,, 'AIR (i Sha'TIC SYSTEM
/ ONLto Staie and I,oi1: septic variances.
t3oartth review and altpru al is required for
any additionslren„.auon_,+Iterations to
sewaies and/or structuresld..t link.rmouth Health ttcr(>,artrli� �,rAPPROti'h'1l) orD�,�.!��%/
Date \
moi. 'off
P��� Of Mgss9c o�.�o
o� PETER T.
McENTEE
� CIVIL
No. 35109
£c�STEv�� s .
\' PLAN REVISION — 2/1 /19
1) S.A.S. LOCATION ,
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
1261 ROUTE 28, SOUTH YARMOUTH, MA
Prepared for: D. A. Brown, Inc., P.O. Box 145, Centerville, MA 02632
Engineering by: Survey Review by: SCALE DRAWN JOB. NO.
Engineering Works, Inc. JC Engineering, Inc. 1 "=60' P.T.M. 105-14
12 West Crossfield Road 2854 Cranberry Hwy. DATE CHECKED SHEET N0.
Forestdole, MA 02644 E.Wareham, MA 02538
(508) 477-5313 (508) 273-0377 10/20/18 P.T.M. 1 Of 3
102,38
/ % BENCHMARK
` SYSTEM ni„G /1 MANHOLE RlM
102.29
BUILDING -7 TEM .,A.» ... PK SET
T.O.F.=102.4± i 101,77
�\ 101,,80' 100.74
Fri
V.
--64--
EXISTING CONTOUR
x 60.98
EXISTING SPOT GRADE
TEST PIT
BENCHMARK
LEGEND
EXISTING SEPTIC TANK
(TO REMAIN)
INV. (OUT)=97.83-+
fCB v'
100,06 X01 01.
,r OVENT r'-
:. O
102,796±S.F.
gfl'�
2.36±Ac.
�� rr
PARCEL ID: 60-196
^ f� 98.98
V� iTP LAMP ` J
101,23 BOARD
EXIS G LEACH PITS
TO BE PUMPED, FILLED
lTH SAND & ABANDONED
v
r
r� 99.72
X
100,15 -z i
r
r /
` 0I
i
N* OF Mgssq�y�
� SHUFFLE
� x 99,74
+ 00`44
S ORT 0.00
99:91 --
� I
99.96
IPATlO /
POOL
I I !1
i
I I
I I
I I
I
I
i IN GROUND
SWIMMING
POOL
I
I I
100.00
� I
-J
x 99,53 r� rr'r
GS r
r
� JI
\\ + 99.66
99.61
CABANA
// /
+ 98.84
x 98.72 98.36
98.01
CB �
99.05 r/
o PETER T. ,,
MCENTEE
PROPOSED SEPTIC SYSTEM UPGRADE
PLAN
PLAN REVISION - 2/1/19
CIVIL
No. 35109
1) S.A.S. LOCATION
1261 ROUTE 28, SOUTH YARMOUTH,
MA
R£G/SZE` ��
Prepared for: D. A. Brown, Inc., P.O. Box 145, Centerville,
MA 02632
E
Engineering by:
Survey Review by:
SCALE
DRAWN
JOB. N0.
(
C
OWNER OF RECORD
1261 BASS RIVER REALTY LLC
Engineering Works, Inc.
West Crossfield Road
JC Engineering, Inc.
2854 Cranberry Hwy.
1 "=20'
P.T.M.
105-14
7 CENTRAL STREET
12
Forestdole, MA 02644
E.Wareham, MA 02538
DATE
CHECKED
SHEET N0.
SOUTH EASTON, MA 02375
(508) 477-5313
(508) 273-0377
10/20/18
P.T.M.
2 Of 3
NOTE: TO PREVENT BREAKOUT, FINAL GRADE
SHALL NOT BE AT, OR BELOW, EL.=97.0
FOR A DISTANCE OF 15' FROM THE EDGE
SEPTIC TANK PROPOSED D -BOX OF THE PROPOSED S.A.S.
INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & WATERTIGHT
OUTLET AND SET TO 6" OF FINISH GRADE COVER SET TO 6" OF GRADE PROPOSED S.A.S.
INSTALL RISER & COVER OVER ONE CHAMBER AND
T.O.F.=102.4± SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT
F.G. EL.=102.9± F.G. EL.=102.0± F.G. EL.=101.0± F.G. EL.=101.01
VENT
MAINTAIN 2% SLOPE OVER S.A.S.
L= 76' L= 5'
S=1% (MIN.) p S=1% (MIN.) 2" LAYER OF 1/8" TO 1/2"
_ 4"SCH40 PVC 4"SCH40 PVC
6" DOUBLE WASHED STONE
is"1 as Qr� 00 (OR APPROVED FILTER FABRIC)
14" 6 6000868
EXISTING 48" LIQUID 0008888 ---3/4" To 1-1/2" DOUBLE
LEVEL 4.8' 4' WASHED STONE
ADD4'
GAS BAFFLEINV.=96.77 PROPOSED INV.=96.60
EFFECTIVE WIDTH = 12.8'
INV.=97.83± D -BOX
EXISTING INV.=96.50
EXISTING SEPTIC TANK 2-500 GALLON LEACHING CHAMBERS
SURROUNDED WITH STONE AS SHOWN
H-20 RATED
NOTES:
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE TOP CONC. ELEV.=97.6±
INVERTS, PRIOR TO INSTALLATION. BREAKOUT ELEV.=97.0
INV. ELEV.=96.50 mmHg 9108882
2) D -BOX SHALL BE SET LEVEL AND TRUE TO aaaaaaaaaaa
GRADE ON A MECHANICALLY COMPACTED SIX aaaaaaaaaaa
INCH CRUSHED STONE BASE, AS SPECIFIED IN BOTTOM ELEV.=94.50
4' 2 x 8.5' = 17.0' 4'
310 CMR 15.221(2). 4' OF NATURALLY OCCURRING EFFECTIVE LENGTH = 25.0'
3 PERVIOUS MATERIAL INSTALL INLET & OUTLET TEES AS REQUIRED.
4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE 5' (MIN.) ABOVE G.W.
AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. LEACHING SYSTEM SECTION
NO G.W., EL=89.5 -
SEPTIC SYSTEM PROFILE PLAN REVISION - 2/1/19
1) S.A.S. LOCATION
N.T.S.
®®®® 0 ®®®®
®®®®®®®®®®® 37„
®®®®®®®®®®®
N Z ®QT®®®®®®®®®
102"
4" KNOCKOUT
LQ_ ss
COVER
F*
4" KNOCKOUT 4" KNOCKOUT 58"
� R
P? N cSj
4" KNOCKOUT
N 0'
W
500 GALLON CAPACITY, H-20 LOADING
�
%w.
CHAMBERS
S P�'
% eR°P 25
SOIL LOG
DATE: OCTOBER 18, 2018
SOIL EVALUATOR: PETER McENTEE PE(SE#1542)
SEPTIC LAYOUT
WITNESS: PHIL RENAUD R.S. HEALTH AGENT
ELEV. TP DEPTH
101.0 A 0"
LOAMY SAND
10YR 4/2
100.3 7"
DESIGN CRITERIA
BLOAMY SAND
10YR 5/8
NUMBER OF BEDROOMS: 3 BEDROOMS (UNITS 7, 8 & 9)
s8 -o G Li 36"
PERC
SOIL TEXTURAL CLASS: CLASS 1
23"/41"
DESIGN PERCOLATION RATE: <2 MIN/IN
MED. SAND
DAILY FLOW: 330 G.P.D.
2.5Y 6/6
DESIGN FLOW: 330 G.P.D.
GARBAGE GRINDER: NO -not allowed with design
LEACHING AREA REQUIRED: (330) = 445.9 S.F.
89.5 138"
•74
PERC RATE <2 MIN/IN. "C" HORIZON
EXISTING SEPTIC TANK: 1000 GALLON CAPACITY
NO GROUNDWATER ENCOUNTERED
PROPOSED D -BOX: 1 INLET, 3 OUTLETS, H-10 RATED
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
USE 2-500 GALLON LEACHING CHAMBERS IN SERIES
1261 ROUTE 28, SOUTH YARMOUTH, MA
SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES
SIDEWALL AREA: 2(12.8' + 25.0') X 2 = 151.2 S.F.
Prepared for: D. A. Brown, Inc., P.O. Box 145, Centerville, MA 02632
Engineering by:
Survey Review by:
SCALE
DRAWN
JOB. No.
BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F.
Engineering Works, Inc.
JC Engineering, Inc.
1 "=20'
P.T.M.
105-14
TOTAL AREA: .............................................................. 471.2 S.F.
12 West Crossfield Road
2854 Cranberry Hwy.
DATE
CHECKED
SHEET NO.
DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.7 GPD
Forestdole, MA 02644
(508) 477-5313
E.Warehom, MA 02538
(508) 273-0377
10/20/18
P.T.M.
3 of 3