HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot 7,6 3 Zone of Contribution: In Out_
Acreage- /
Commercial: Residential✓
Street: ((7 41,--(:„/-- c
Village: k7 f/lt ` Floor Plan: #Bedrooms:
�
Owner: rcr �
Address: Phone: 5-3'J'- 611.-/O//
Phone:
Builder: Engineer: tJ s .'l
Phone: - Sr / ��
Address: C. �b `�
Phone:
N/A YES ly0
1.Required#of copies received ��,,/
2.Date of soils exam and percolation test not older than 2 years 1------
3.4-5
3.4-5 ft of naturally occurring pervious material, above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5. Water line 10 ft from septic components Var.: L-----
6.Benchmark indicated and shown-NGVD if near wetlands '
7. Septic tank minimum 10 ft from foundation, deck Var.: t...®---
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 1/4_____-
9.Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.: (.....---
12. System meets all other setback requirements Var.: _
13.Uses adjustment for maximum high groundwater Var.: --°
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: y-
15. System not in top or subsoil(A,B horizons)or 5'removal L_.----"'
16.Proposed contours are suitable L_f _
17. System meets slope requirements-min. 1/8", '/4"preferred
,..------
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel \_7/ _
21.No garbage disposal �_---- --.
22. System adequately sized for its intended use '
23.Minimum 6"stone or compacted below tank and dbox L--'
24.Manhole covers within 6"of grade,pump chamber cover to grade
25.Inspection port on plastic chambers/leach field �-- -'
26.Electrical permit for pump chamber/Separate meter for duplexes --
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size '
28. Septic tank/pump chamber to be factory waterproofed
29.Vent provided if leaching below 3 feet,under driveway/parking
30.Buoyancy calculations for tank/pump chamber
31.Engineer to inspect and certify soils: wall: commercial: -i''--
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature :,/"
33.H-20 loading is subject to vehicular traffic, groundwater ------'.
34.Title V Application and permit fee, installer signature _�''-
35.Foundation footing min. 2 feet above adjusted ground water for new house ,,----
36.Deed Restriction required max. #bedrooms: max. flow: gpd ----
37.Check area lots for groundwater/Label groundwater in Assessor's Map
�
z
Plan reviewed by: `� 6/03/03