Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot 7,6 3 Zone of Contribution: In Out_ Acreage- / Commercial: Residential✓ Street: ((7 41,--(:„/-- c Village: k7 f/lt ` Floor Plan: #Bedrooms: � Owner: rcr � Address: Phone: 5-3'J'- 611.-/O// Phone: Builder: Engineer: tJ s .'l Phone: - Sr / �� Address: C. �b `� Phone: N/A YES ly0 1.Required#of copies received ��,,/ 2.Date of soils exam and percolation test not older than 2 years 1------ 3.4-5 3.4-5 ft of naturally occurring pervious material, above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: L----- 6.Benchmark indicated and shown-NGVD if near wetlands ' 7. Septic tank minimum 10 ft from foundation, deck Var.: t...®--- 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 1/4_____- 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: (.....--- 12. System meets all other setback requirements Var.: _ 13.Uses adjustment for maximum high groundwater Var.: --° 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: y- 15. System not in top or subsoil(A,B horizons)or 5'removal L_.----"' 16.Proposed contours are suitable L_f _ 17. System meets slope requirements-min. 1/8", '/4"preferred ,..------ 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel \_7/ _ 21.No garbage disposal �_---- --. 22. System adequately sized for its intended use ' 23.Minimum 6"stone or compacted below tank and dbox L--' 24.Manhole covers within 6"of grade,pump chamber cover to grade 25.Inspection port on plastic chambers/leach field �-- -' 26.Electrical permit for pump chamber/Separate meter for duplexes -- 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size ' 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: -i''-- 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature :,/" 33.H-20 loading is subject to vehicular traffic, groundwater ------'. 34.Title V Application and permit fee, installer signature _�''- 35.Foundation footing min. 2 feet above adjusted ground water for new house ,,---- 36.Deed Restriction required max. #bedrooms: max. flow: gpd ---- 37.Check area lots for groundwater/Label groundwater in Assessor's Map � z Plan reviewed by: `� 6/03/03