HomeMy WebLinkAboutReview Checklist 7(e6-(l /7
�/ 7
TOWN OF YARMOUTH 44- , <, �J/� / ,
SEWAGE PLAN REVIEW CHECKLIST ,�'' `'7<
Location: A.M. 41. Lot Zone of Contribution: ut Acreag t
Commercial: Residential:
Street: 40 / _
Village: /l. Floor Plan: #Bedrooms: 4 ' 1
Owner: i"16-644/ Installer: 414 3 4i
Address: Phone: 47�2 - .,YS- c 9f
Phone: 5 4P- )6 ( ' -324/
Builder: .yrue Engineer: //
Address: Phone: !J�-0 ilr 74-3'11
Phone:
N/A YES NO
1.Required#of copies received L.------.-
2.
.---'''2.Date of soils exam and percolation test not older than 2 years c-,..--
3.4-5 ft of naturally occurring pervious material,above water table c.----
4.
.---
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ._._-----
5.Water line 10 ft from septic components Var.:
6.Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.:
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: `s-
9.Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.: k.---"
12. System meets all other setback requirements Var.: �---
13.Uses adjustment for maximum high groundwater Var.: `..--'"
14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.: (---'
15. System not in top or subsoil(A,B horizons)or 5'removal t..------
16.
'f16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", 1 "preferred (....---
18. System meets breakout requirements PVC liner: Wall: l__. -
19. Specified tee sizes are proper, gas baffle on outlet tee L_-----
20. Sewage is under 10,000 gpd for parcel �,.-----
21.No garbage disposal L.,----
22. System adequately sized for its intended use c.;.....
23.Minimum 6"stone or compacted below tank and dbox L...--
24.Manhole covers within 6"of grade, pump chamber cover to grade L./ ,
25.Inspection port on plastic chambers/leach field �----
26.Electrical permit for pump chamber/Separate meter for duplexes ---' -
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size .....--
28.
28. Septic tank/pump chamber to be factory waterproofed -_'"-
29.Vent provided if leaching below 3 feet,under driveway/parking -----
30.Buoyancy calculations for tank/pump chamber --- --
_ 31.Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature _,-----'
33.H-20 loading is subject to vehicular traffic, groundwater ------
34.
34. Title V Application and permit fee, installer signature k...-------
35.
35.Foundation footing min.2 feet above adjusted ground water for new house .....---
36.Deed Restriction required max. #bedrooms: max. flow: gpd
37.Check area lots for groundwater/Label groundwater in Assessor's Map\ L--------
Plan
,„---/Plan reviewed by: CV) 6/03/03