HomeMy WebLinkAboutReview Checklist /2 -7/P- TOWN OF YARMOUTH X7 -
SEWAGE PLAN REVIEW CHECKLIST , ,, �7
Location: A.M. A4 Lot 1Z5 Zone of Contribution: In ut Acreage/ �
� r#0:1',41
�,0 1` Commercial• Residential: t.�'
�Street: ��Village: Floor Plan: #Bedrooms: '3 Owner: ��'�p� /j4 L/i/ Installer:
Address: / / Phone:
Phone:
Builder: Engineer: (5,-( t
Address: ZPhone: P--,�� �g
Phone: y l'' /- u' 'GC
- N/A- YES }NO
1.Required#of copies received
2.Date of soils exam and percolation test not older than 2 years (------
3.4-5
...------
3.4-5 ft of naturally occurring pervious material, above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5. Water line 10 ft from septic components Var.: ..___-
6. Benchmark indicated and shown-NGVD if near wetlands -
7. Septic tank minimum 10 ft from foundation, deck Var.: k. .
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.: L__--- .
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: C. _
11.Tank/leaching minimum 10 ft from property line Var.: •..
12. System meets all other setback requirements Var.: 1.......---
13.
,--13.Uses adjustment for maximum high groundwater Var.:
--
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: __.
15. System not in top or subsoil(A,B horizons)or 5' removal
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", V preferred '•..,..--
18.
•.,..--
18. System meets breakout requirements PVC liner: Wall: _ �_.-
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel .,._._,._....--
21.No garbage disposal
22. System adequately sized for its intended use �...._- --
23.Minimum 6"stone or compacted below tank and dbox (....._--
24.Manhole covers within 6"of grade, pump chamber cover to grade (.__---
25.
._.__--
25.Inspection port on plastic chambers/leach field l _..i
26.Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed -.-- ---
29.Vent provided if leaching below 3 feet,under driveway/parking --
30.Buoyancy calculations for tank/pump chamber --
31.Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature C___-'
33.H-20 loading is subject to vehicular traffic, groundwater
34.Title V Application and permit fee, installer signature '
35.Foundation footing min. 2 feet above adjusted ground water for new house ,..-------
36.
-!36.Deed Restriction required max. #bedrooms: max. flow: gpd ---_
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: C'41 6/03/03