HomeMy WebLinkAboutEngineered Plan - 2018TOP FOUND. EL. 27.2' -ACCESS COVER AT FIN. GRADE 27.2' M SYSTEM PROFILE (NOT TO SCALE) PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVER TO WITHIN 6" OF FIN. GRADE INIMUM 1 OF COVER I MINIMUM 75' OF COVER OVER POLY TANK EL. 25.21' OVER PRECAST 16.1"(1.34') 4"OSCH40 PVC *24.7±' 24.12' PROPOSED 1,500 PIPES LEVEL 1ST 2' GALLON POLYETHYLENE 23.87' .y SEPTIC TANK GAS (H-10) BAFFLE '0.000.000000 WATERTEST D'BOX °�����°-°0° FOR LEVELNESS 0 0000000. g 23.66' 23.49' 6' CRUSHED STONE OR MECHANICAL DEPTH OF FLOW = 4' COMPACTION. (15.221 [2]) NOTE: 2" MIN. WALL THICKNESS REQUIRED NOTES ALL SYSTEM COMPONENTS SHALL BE 1. DATUM IS NAVD 88 MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. 2, MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. rEM 26.8 4. DESIGN LOADING FOR ALL PROPOSED UNITS TO PROVIDE INSPECTION PORTS TO BE AASHTO H-10 /WITHIN 3" OF FINISH GRADE 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR REQUIRED TEE SIZES: INLET DEPTH = 10" MIN. BELOW FLOW LINE CONCEALED WITHOUT INSPECTION BY BOARD OF OUTLET DEPTH = 14" MIN. BELOW THE FLOW LINE QUICK4 PLUS STANDARD LOW PROFILE UNITS HEALTH AND PERMISSION OBTAINED FROM BOARD NOTE: STANDARD TEES ARE TO BE USED. DO NOT USE OVERALL DIMENSIONS TO OUTSIDE OF UNITS: 33' X 8.5' OF HEALTH. MANUFACTURER'S TEES THAT COME WITH THE TANK (NO STONE 0RO0OSED0 0 V G 0 �h/Po i i ooh � o X o , L ocusCb C'' � m 3 o 3 Xit O Q Rou c {e 6 s, 0/d Townhouse Rd. 1v n 1 .CONTRACTOR SHALL BE RESPONSIBLE FOR ( 2 SLOPE) ( 1 %SLOPE) (1 SLOPE) 6' CALLING VERIFYING ITHE LOCATION OF ALL UNDERGROUND & LOCUS MAP MIN. ' LEACHING OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF FOUNDATION- 29 SEPTIC TANK 21 D BOX 4' FACILITY WORK. SCALE 1"=2000'± *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 106 PARCEL 40 UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS BOTTOM TH 1 EL. 16.8' BE REMOVED BENEATH AND 5' AROUND THE PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- - 99- EXISTING CONTOUR X 99• ' EXIST. SPOT ELEV. -[99}- PROPOSED CONTOUR (98.4] PROPOSED SPOT EL. TH1 TEST HOLE 2% SLOPE OF GROUND UTILITY POLE downcope.com FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: PHIL RENAUD DATE: 11/21/18 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 0" 27.3' A LS 12" 10YR 3/6 B LS 30" 10YR 5/6 24.8' PERC C FS 1OYR 7/4 126" I 116.8' NO GROUNDWATER ENCOUNTERED LICE #,U--424 f raze ' 1,-4 11145. Scale: 1 "= 20' --m 0 10 20 30 40 50 FEET 2ND FLOOR 1 ST FLOOR PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE X 12. EXISTING LEACHING FACILITY SHALL BE PUMPED (AREA OF MINIMAL FLOOD HAZARD) AS AND REMOVED OR PUMPED AND FILLED WITH CLEAN SHOWN, ON COMMUNITY PANEL #25001 CO578J SAND. DATED 7/16/2014 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM DWELLING DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. H-10 POLYETHYLENE SEPTIC TANK LEACHING: 4.73 SF/LF x 4' LENGTH = 18.92 SF PER QUICK4 PLUS STANDARD LP UNIT 330 GPD/0.74 GPD/SF = 446 SF LEACHING REQ'D 446 SF/18.92 SF/UNIT = 23.6 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (24) QUICK4 PLUS STANDARD LP UNITS IN FIELD CONFIGURATION OF 3 ROWS OF 8 UNITS INING OOM 24 UNITS x 18.92 SF/UNIT = 454 SF> 446 SF 454 SF (0.74) = 336 GPD (OK) FLOOR PLAN I -0T, TO SCALE t t --1-s- vow DATE DANIEL A. OJALA, P.E., P.L.S. APPROVED MA DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF #85 FREEMAN ROAD YARMOUTH PORT, MA PREPARED FOR EVELYN LIU DATE: NOVEMBER 28, 2018 > C7 =, off 508-362-4541 fax 508-362-9880 -p downcope.com 7-1 down cnpe engine@ring, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 18-424 CCSEPTIC-LIU.DWG