HomeMy WebLinkAboutReview Checklist ..,, - 7- / f 706(.._ -
TOWN OF YARMOUTH ,�,/ 6 "Ael
SEWAGE
PLAN REVIEW CHECKLIST �i' r
Location: A.M. 7 Lot 1% Zone of Contribution: In✓Out Acreage�� �if',�>�
Commercial: Residential: t/',,. t 0�`
Street: g S TV(N/,�/(/l p... ""/ / ,
Village: i, <,4f,V Floor Plan: I #Bedrooms:
Owner: y12f1/4f / 10,!/e6 Installer: Sr
Address: Phone: q77 05-3
Phone:
Builder: Engineer: kOked. 41(003.0/
Address: Phone: ' i67-/‘/7
Phone: i P5/y. 1
N/A YES NO
1.Required#of copies received
2. Date of soils exam and percolation test not older than 2 years t.--------
3. 4-5
.�-----3. 4-5 ft of naturally occurring pervious material, above water table l--,--'-.
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓
5.Water line 10 ft from septic components Var.: (,,-.'''
6.Benchmark indicated and shown-NGVD if near wetlands C.-------
7. Septic tank minimum 10 ft from foundation, deck Var.:
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: (......----
9.Leaching minimum 100 ft from wetlands Var.: .--/ _
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: (..-------
11. Tank/leaching minimum 10 ft from property line Var.: (.....--.---
12. System meets all other setback requirements Var.: ��-
13.Uses adjustment for maximum high groundwater Var.: k./
14. Leaching set 4-5 ft above adj.water or bottom of test hole Var.: (,v--'''.
15. System not in top or subsoil(A,B horizons) or 5' removal t s
16.Proposed contours are suitable C...-------
17. System meets slope requirements-min. 1/8", 'A"preferred L.-------
18. System meets breakout requirements PVC liner: Wall: L...----
19. Specified tee sizes are proper, gas baffle on outlet tee L---'
20. Sewage is under 10,000 gpd for parcel t_�
21.No garbage disposal l.----•
22. System adequately sized for its intended use 1/4-------
23.Minimum 6"stone or compacted below tank and dbox \-----
24.
.r24.Manhole covers within 6"of grade,pump chamber cover to grade L1
25.Inspection port on plastic chambers/leach field ...._,.
26.Electrical permit for pump chamber/Separate meter for duplexes ......----
27.Pump system-2" line,weep hole,check valve, tee in dbox, pump size -------
28. Septic tank/pump chamber to be factory waterproofed --------
29.Vent provided if leaching below 3 feet,under driveway/parking
30.Buoyancy calculations for tank/pump chamber
31.Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic, groundwater ,.------4
34.Title V Application and permit fee, installer signature - /
35.Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: - max. flow:Z?----d gpd --------
37.
-s37.Check area lots for groundwater/Label groundwater in Assessor's Map L.S
Plan reviewed by: eiO3iO3