Loading...
HomeMy WebLinkAboutReview Checklist t> /7 ./ TOWN OF YARMOUTH . SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 6,---6 Lot c 5- Zone of Contribution: In Out (Aereage rC ' ��/% /dCommercial: Residential: Street: ` fi '� - Village: , 7 4-/ Floor Plan: `------ #Bedrooms: 3 Owner: /1V(f "/(,.(1/1..1,--rInstaller: ,� Ai," Address: Phone: �S -i-L -Q'9 i-0---- Phone: Ri � �i Builder: Engineer: Address: Phone: --36--f --� , Phone: N/A YES NO 1.Required#of copies received i 2. Date of soils exam and percolation test not older than 2 years c _ 3. 4-5 ft of naturally occurring pervious material, above water table :,. , 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: __-- 6.Benchmark indicated and shown-NGVD if near wetlands L.-� 7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: _ - 9. Leaching minimum 100 ft from wetlands Var.: --- 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 1 11.Tank/leaching minimum 10 ft from property line Var.: 1 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: -- 14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.: -' 15. System not in top or subsoil(A,B horizons)or 5' removal 16.Proposed contours are suitable L.- °- 17. .- "17. System meets slope requirements-min. 1/8", 1/4"preferred t.----- 18. i18. System meets breakout requirements PVC liner: Wall: L.------ 19. ./19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 1/4.--_- 21.Noarba a disposal C.--- g g P 22. System adequately sized for its intended use 1. .---- 23.Minimum 6"stone or compacted below tank and dbox - 24.Manhole covers within 6"of grade,pump chamber cover to grade (----- 25.Inspection port on plastic chambers/leach field -- 26.Electrical permit for pump chamber/Separate meter for duplexes 1/4------ 27. -i27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size "_- 28. Septic tank/pump chamber to be factory waterproofed 1/4._..-/ 29.Vent provided if leaching below 3 feet, under driveway/parking L---- 30.Buoyancy calculations for tank/pump chamber s 31.Engineer to inspect and certify soils: wall: commerial•, 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature (%C \> , 'i 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee, installer signature - 3 5.Foundation footing min.2 feet above adjusted ground water for new house ._-___-' 36.Deed Restriction required max. #bedrooms: max. flow: gpd - 37. Check area lots for groundwater/Label groundwater in Assessor's Ma -- Plan reviewed by: 6/03/03