HomeMy WebLinkAboutReview Checklist (/ )4 /r" TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. et- Lot 67 7 Zone of Contribution: In Out_ Acreage
Commercial: Residential: -
Street: 25 /'Y9 AZ, /
Village: - �f Floor Plan: V #Bedrooms: -3 .
Owner: Ks ,/562 Installer: (p' ( 0(4-1/41/15
Address:
/ Phone:
Phone:
J1
Builder: Engineer: '.2/19 y 1 Ili
Z oestio5W
Address: Phone: 5-6e7 PliC - ,"-t
, ,
Phone: /P`' �?u/ � -et
N/A YES NO
1.Required#of copies received jam..-
2.Date of soils exam and percolation test not older than 2 years L. _
3.4-5 ft of naturally occurring pervious material, above water table 'L------
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic components Var.: (....----
6.
si6.Benchmark indicated and shown-NGVD if near wetlands L /
7. Septic tank minimum 10 ft from foundation, deck Var.: C....-�'
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.: L.---
.
12. System meets all other setback requirements Var.: ,c......----'
_- -'
13.Uses adjustment for maximum high groundwater Var.: _ ----'
14.Leaching set 4-5 ft above adj.water or botto est Var.: �----
15. System not in top or subsoil(A,B horizons) 5'reml -
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", 1/4"preferred ',L /-
18. System meets breakout requirements PVC liner: Wall: L/--- r
19. Specified tee sizes are proper, gas baffle on outlet tee i.-----
20. Sewage is under 10,000 gpd for parcel `-.-
21.No garbage disposal L�-/
22. System adequately sized for its intended use \.__,------
23.
tir---�23.Minimum 6"stone or compacted below tank and dbox ‘......---
24.
- --24.Manhole covers within 6"of grade,pump chamber cover to grade i..--
25. Inspection port on plastic chambers/leach field C.-i
26.Electrical permit for pump chamber/Separate meter for duplexes (------
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size k..-----
28.
.../28. Septic tank/pump chamber to be factory waterproofed .- -
29.Vent provided if leaching below 3 feet, under driveway/parking ,.....----
30. Buoyancy calculations for tank/pump chamber ,......--
31.Engineer to inspect and certify soils: wall: commercial: --
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic, groundwater `..
34.Title V Application and permit fee, installer signature �,/
35.Foundation footing min. 2 feet above adjusted ground water for new house ..-y---"
36.Deed Restriction required max. #bedrooms: max. flow: gpd ,_______--
37.
_,._37.Check area lots for groundwater/Label groundwater in Assessor's Map -'-
Plan reviewed by:
i' 6/03/03