Loading...
HomeMy WebLinkAboutReview Checklist (/ )4 /r" TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. et- Lot 67 7 Zone of Contribution: In Out_ Acreage Commercial: Residential: - Street: 25 /'Y9 AZ, / Village: - �f Floor Plan: V #Bedrooms: -3 . Owner: Ks ,/562 Installer: (p' ( 0(4-1/41/15 Address: / Phone: Phone: J1 Builder: Engineer: '.2/19 y 1 Ili Z oestio5W Address: Phone: 5-6e7 PliC - ,"-t , , Phone: /P`' �?u/ � -et N/A YES NO 1.Required#of copies received jam..- 2.Date of soils exam and percolation test not older than 2 years L. _ 3.4-5 ft of naturally occurring pervious material, above water table 'L------ 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: (....---- 6. si6.Benchmark indicated and shown-NGVD if near wetlands L / 7. Septic tank minimum 10 ft from foundation, deck Var.: C....-�' 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: L.--- . 12. System meets all other setback requirements Var.: ,c......----' _- -' 13.Uses adjustment for maximum high groundwater Var.: _ ----' 14.Leaching set 4-5 ft above adj.water or botto est Var.: �---- 15. System not in top or subsoil(A,B horizons) 5'reml - 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", 1/4"preferred ',L /- 18. System meets breakout requirements PVC liner: Wall: L/--- r 19. Specified tee sizes are proper, gas baffle on outlet tee i.----- 20. Sewage is under 10,000 gpd for parcel `-.- 21.No garbage disposal L�-/ 22. System adequately sized for its intended use \.__,------ 23. tir---�23.Minimum 6"stone or compacted below tank and dbox ‘......--- 24. - --24.Manhole covers within 6"of grade,pump chamber cover to grade i..-- 25. Inspection port on plastic chambers/leach field C.-i 26.Electrical permit for pump chamber/Separate meter for duplexes (------ 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size k..----- 28. .../28. Septic tank/pump chamber to be factory waterproofed .- - 29.Vent provided if leaching below 3 feet, under driveway/parking ,.....---- 30. Buoyancy calculations for tank/pump chamber ,......-- 31.Engineer to inspect and certify soils: wall: commercial: -- 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater `.. 34.Title V Application and permit fee, installer signature �,/ 35.Foundation footing min. 2 feet above adjusted ground water for new house ..-y---" 36.Deed Restriction required max. #bedrooms: max. flow: gpd ,_______-- 37. _,._37.Check area lots for groundwater/Label groundwater in Assessor's Map -'- Plan reviewed by: i' 6/03/03