Loading...
HomeMy WebLinkAboutReview Checklist Zpi‘e .de 2 - 7 I / TOWN OF YARMOUTH I SEWAGE PLAN REVIEW CHECKLIST Air" ,..› •&_411"kdS41 } Location: A.M. 7 7 Lot 7 Zone of Contribution: Inc... Out_ Acreage S 5--•� Commercial: Residential: Street: 6 cj es8.„‘9,„ Village: . Floor Plan: L - #Bedrooms: 2_ i i Owner: rre_ed( &//4t Installer: /6(3 e, . Address: Phone: i 11 0. ---- Phone: 2 r. 0 /i Builder: Engineer: '� Address: Phone: I . --�� -- ., „.Phone: � �c �� �,� ,� ��r/s- (z5 N/A YES NO 1.Required#of copies received (! 2.Date of soils exam and percolation test not older than 2 years t..----' 3.4-5 ft of naturally occurring pervious material, above water table �.---- 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: �.-----• 5.Water line 10 ft from septic components Var.: �1,� 6.Benchmark indicated and shown-NGVD if near wetlands t/ 7. Septic tank minimum 10 ft from foundation, deck Var.: �--� 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: (.....---- 9. /9.Leaching minimum 100 ft from wetlands Var.: c---- 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: k-..---- 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: k.......-----• 14.Leaching set 4-5 ft above adj.water or bo'.m of tes -. ,ar.: ‘...---- 15. System not in top or subsoil(A,B horizon' or 5'rem. k.----- 16. .-.✓16.Proposed contours are suitable ��-> 17. System meets slope requirements-min. 1/8", 'A"preferred �._ 18. System meets breakout requirements PVC liner: Wall: `� '19. Specified tee sizes are proper, gas baffle on outlet tee L_� 20. Sewage is under 10,000 gpd for parcel \---. 21.No garbage disposal �� 22. System adequately sized for its intended use Lam.. . 23.Minimum 6"stone or compacted below tank and dbox 24.Manhole covers within 6"of grade,pump chamber cover to grade ....._--- 25. Inspection port on plastic chambers/leach field �-..-. 26. Electrical permit for pump chamber/Separate..meter for duplexes - 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size ..._.----,- 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet, under driveway/parking 30.Buoyancy calculations for tank/pump chamber ,S' 31.Engineer to inspect and certify soils: wall: commercial: ��' 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature k - (-9 33.H-20 loading is subject to vehicular traffic, groundwater �„S 34.Title V Application and permit fee, installer signature - .---/ 35.Foundation footing min. 2 feet above adjusted ground water for new house ..®--' 36.Deed Restriction required max. #bedrooms:-z .max. flow: �gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map L.-/- Plan reviewed by: 6/03/03