HomeMy WebLinkAboutReview Checklist Zpi‘e .de
2 - 7 I / TOWN OF YARMOUTH
I SEWAGE PLAN REVIEW CHECKLIST Air" ,..› •&_411"kdS41
} Location: A.M. 7 7 Lot 7 Zone of Contribution: Inc... Out_ Acreage S 5--•�
Commercial: Residential:
Street: 6 cj es8.„‘9,„
Village: . Floor Plan: L - #Bedrooms: 2_
i i
Owner: rre_ed( &//4t Installer: /6(3 e, .
Address: Phone: i 11 0. ----
Phone: 2 r.
0 /i
Builder: Engineer: '�
Address: Phone: I . --�� -- ., „.Phone: � �c
��
�,� ,� ��r/s- (z5
N/A YES NO
1.Required#of copies received (!
2.Date of soils exam and percolation test not older than 2 years t..----'
3.4-5 ft of naturally occurring pervious material, above water table �.----
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: �.-----•
5.Water line 10 ft from septic components Var.: �1,�
6.Benchmark indicated and shown-NGVD if near wetlands t/
7. Septic tank minimum 10 ft from foundation, deck Var.: �--�
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: (.....----
9.
/9.Leaching minimum 100 ft from wetlands Var.: c----
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.: k-..----
12. System meets all other setback requirements Var.:
13.Uses adjustment for maximum high groundwater Var.: k.......-----•
14.Leaching set 4-5 ft above adj.water or bo'.m of tes -. ,ar.: ‘...----
15. System not in top or subsoil(A,B horizon' or 5'rem. k.-----
16.
.-.✓16.Proposed contours are suitable ��->
17. System meets slope requirements-min. 1/8", 'A"preferred �._
18. System meets breakout requirements PVC liner: Wall: `�
'19. Specified tee sizes are proper, gas baffle on outlet tee L_�
20. Sewage is under 10,000 gpd for parcel \---.
21.No garbage disposal ��
22. System adequately sized for its intended use Lam.. .
23.Minimum 6"stone or compacted below tank and dbox
24.Manhole covers within 6"of grade,pump chamber cover to grade ....._---
25. Inspection port on plastic chambers/leach field �-..-.
26. Electrical permit for pump chamber/Separate..meter for duplexes -
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size ..._.----,-
28. Septic tank/pump chamber to be factory waterproofed
29.Vent provided if leaching below 3 feet, under driveway/parking
30.Buoyancy calculations for tank/pump chamber ,S'
31.Engineer to inspect and certify soils: wall: commercial: ��'
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature k -
(-9
33.H-20 loading is subject to vehicular traffic, groundwater �„S
34.Title V Application and permit fee, installer signature - .---/
35.Foundation footing min. 2 feet above adjusted ground water for new house ..®--'
36.Deed Restriction required max. #bedrooms:-z .max. flow: �gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map L.-/-
Plan reviewed by: 6/03/03