HomeMy WebLinkAboutReview Checklist 0- Z �O f TOWN OF YARMOUTH / .`�C `
SEWAGE PLAN REVIEW CHECKLIST /6(; , _ "
Location: A.M 9 0 Lot 7 7 Zone of Contribution: In c/Uut_ Acreage.14Q-1) 5
i - / Commercial: Residential: L__,.....--
Street:
/Street: • 7 -Ai. a 41 10 ,,
Village: !/ riy
Floor Plan: / / #Bedrooms:
Owner P -" Installer: 7 t, /' ,y 1' C W
Address: Phone:
Phone:
Builder: Engineer: ,ç- e.. 4/ , "
Address: Phone: •w; - ` r 'jam /
Phone: �� ?i
.___. 4/ N/A � NO
1.Required#of copies received
2.Date of soils exam and percolation test not older than 2 years .....-----
3.4-5
.,.----3.4-5 ft of naturally occurring pervious material, above water table ,
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic components Var.: �.--
6.Benchmark indicated and shown-NGVD if near wetlands (...------
7. Septic tank minimum 10 ft from foundation, deck Var.: �-
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: L...
9.Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.: / ‘.....---
12.
..- -12. System meets all other setback requirements Var.: `,...�
13.Uses adjustment for maximum high groundwater Var.: t....___--
14.
`-14.Leaching set 4-5 ft above adj.water or bottom o st hole Var.:
15. System not in top or subsoil(A,B horizons) 5'remo al;
I 16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", ' "preferred tom-
18. System meets breakout requirements PVC liner: Wall: :r---
19. Specified tee sizes are proper, gas baffle on outlet tee --=
20. Sewage is under 10,000 gpd for parcel __
21.No garbage disposal L.._
22. System adequately sized for its intended use
23.Minimum 6"stone or compacted below tank and dbox L<„`=-
r 24.Manhole covers within 6"of grade,pump chamber cover to grade t_._--
25.Inspection port on plastic chambers/leach field ‘.---
26.
26.Electrical permit for pump chamber/Separate meter for duplexes �___._---
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed ._---- .
29.Vent provided if leaching below 3 feet, under driveway/parking �-
30.Buoyancy calculations for tank/pump chamber
31.Engineer to inspect and certify soils: wall: commercial: -s'
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature ( )
33.H-20 loading is subject to vehicular traffic, groundwater ?
34.Title V Application and permit fee, installer signature C
35.Foundation footing min. 2 feet above adjusted ground water for new house 1/4.____---
36.Deed Restriction required max. #bedrooms: max. flow: gpd -----
37.
--37.Check area lots for groundwater/Label groundwater in Assessor's Map -
Plan reviewed by: 6/03/03