Loading...
HomeMy WebLinkAboutEngineered Plan - 2019ALWAYS DIG SAFE PRIOR TO CONSTRUCTION --UTILITY LOCATIONS SHOWN INCOMPLETE. a_ l; CO MAXIMUM -FEASIBLE COMPLIANCE APPROVALS 'REQUESTED: 04 0 1. VARY SEPTIC TANK TO GARAGE BY 3' (7' PROVIDED). M 310 CMR 15.211 (1). J o_ N /F CRAWFIS & BROWN BENCH MARK--N.W. CORNER OF CONC. BULKHEAD=59.59 ASSIGNED N/F `�- 3 4.4 6 1 31.81 7 x;64 MACOMBER 3t , .6 %1,79 X 35,1 4.7 Brk Patio / o x .4,6 4... X 1 ;.7 X 34,5 3 �• 4,10 4 X �i-�� x 3 .4 / :B2 3 ESERYE4,6 i2g-10" 5, ..9" r�32 /1 ko I Q-_� 2934.8 �n � 32.E 31. X 0 34.4 X 1 33,25 i ^-�, �� ^--, x� -4,5 USE 34,1 < 2.51 X `. xt t �_• TH 1 �Ilc>'j \��_:..::: • ...-..... x 34 9 ' V 9�` x 33.5 j :. 4,1 __x _34,8 4,3 1 '1 f �1 bpS� 7 I �< X 3 :7 Ment 3 I Z 33.7 30,9(0 n Un x 15.0 1 3 5.4 0 32, x��� 7 1 I 34,71 LOT 43 3 .2 \J � W ,3 i \ x I 31.� \ \\ 1 z 1 34 \ l l I Of o a 111866±S.F. r 318 N/ F \ � \y 32.5 � F.,� � 30,66 \ Z 1 31.1 32,25 /30.52 PETTY-MCGINN 3A.41 1 x 1.61 x 32.7 x 32./�x 31,5 % 1 \ 1 � J� 1 Q I 1 31.18 I 31,X 6 30502• W J , x 31.4 �0,50 30,43 31.77 S 79° -, 30.80 1 n 3 .43 2 Edge pavem t 30.10 0 p\'D -0.03 F\\ DE U'BENCH MARK --TOP & CENTER OF 0 CONC. BOUND= 32.36 ASSIGNED t 30.00 BENCH MARK --TOP OF SPIKE SET IN GROUND=30.00ASSIGNED (1.9' OFF E.P. do 129' OFF RANGE UNE NO. 101) -" ® P.97 35.61± Top Foul Invert 32.77 Existing LEG END T 1 TEST HOLE LOCATION, NUMBER W WATER LINE MARKINGS G GAS LINE MARKINGS x 9.5 x8,7 EXIST. & PROP. ELEVATIONS ('X' MARKS POINT) ,,-6-_ EXISTING CONTOUR 8--- PROPOSED CONTOUR Mash29 (1500' South)* UTILITY POLE (IF SHOWN) ® EXISTING DRAINAGE CATCH BASIN x - FENCE (IF SHOWN, NOT ALL SHOWN) 0 TREE (IF SHOWN, NOT ALL SHOWN) -" ® P.97 35.61± Top Foul Invert 32.77 Existing D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. Ftd. 9. DEPTH OF COMPONENTS NOT TO EXCEED 3', . OR . VENTING .MUST BE PROVIDED. t°�o�\on Ave COVERS: BUILD UP COVERS TO 6" BELOW GRADE --2 ON TANK, 1 ON D -BOX, 2 ON LEACHING 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP. LOCATION MAP . 11. IF UNSUITABLE SOILS, .OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, -- CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. 12. IF AN OVERDIG. IS. CALLED FOR. BELOW, FILL MATERIAL FOR 5' AROUND: AND, UNDER LEACHING TEST HOLE 1 1S TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). 13. PUMP AND FILL ANY EXISTING CESSPOOL/LEACHPIT. REMOVE ANY CLOGGED SOIL, BLOCK, DEPTH (inches) ELEV.(feet) AND STONE IN LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT. 0 33 3 14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. TEST HOLE DATE: March 7, 2019 12" NO GRADE CHANGES PERFORMED BY: Ron Cadillac, Soil Evaluator L WITNESSED BY: Amy Von Hone, RS, CHO 30"Q ARE PROPOSED PERC RATE: <2'-001'/inch (B layer) SOIL SURVEY(1993): Carver coarse sand 48" GEOLOGIC MAP(1986): Harwich outwash plain deposits 12 ADS ARC 36HC HD Invert 32.59 Invert 32.05 CHAMBERS Existing pvc Proposed 72„ Use Gas Baffle Invert. 31..63 Top Units.=32.03 Proposed ® Filter Cloth I Proposed S=1 /8" eft S=1/8"/ft. 3" Max. t 1500 � Gal. _- t Inspection Port 108" 1 i Se tic Tank �(\� " Fill B layer 10yr 6/8 loamy sand C1 layer 2.5y 6/6 medium sand C2 layer 2.5y 6/2 silty clay loam _observed water _ I Invert 32.30 I i Existing 10.75" t I *Official Adjustment is 0.0 Using j 1 6 stone or compact Invert 31.80 Invert 31.60 30.7 AIW 230 ---This did not work well t I I I Proposed Proposed 5 Bottom at 154 Capt Small Nearby t I ' 1 JOB NO. Y19-03 519 25'-,I NOTES Dwinell.dw9 NOT TO SCALE � 1. LOCUS IS A.M. 77, PARCEL 119. FB34/14 SB14/00 N 2. ELEVATIONS SHOWN ARE ASSIGNED. Mash29 (1500' South)* v 3. LOCUS IS IN FLOOD ZONE X(OUTSIDE 0.2% RISK) ON FIRM DATED JULY 16; 2014. BEDROOMS: 4. ALL PIPES TO BE 4" SCR 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED)5. MUNICIPAL (N 100' ARE ON TOWN WATER. ATORIS AVAILABLE. 6' mrrlec La 6. COMPONENTS BE AASHTO H-1Q,OTS UNL SS NOTED. 7. INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14 USE 12 ADS ARC 36HC CHAMBERS 8. IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW IN TWO Capt.- R D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. Ftd. 9. DEPTH OF COMPONENTS NOT TO EXCEED 3', . OR . VENTING .MUST BE PROVIDED. t°�o�\on Ave COVERS: BUILD UP COVERS TO 6" BELOW GRADE --2 ON TANK, 1 ON D -BOX, 2 ON LEACHING 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP. LOCATION MAP . 11. IF UNSUITABLE SOILS, .OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, -- CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. 12. IF AN OVERDIG. IS. CALLED FOR. BELOW, FILL MATERIAL FOR 5' AROUND: AND, UNDER LEACHING TEST HOLE 1 1S TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). 13. PUMP AND FILL ANY EXISTING CESSPOOL/LEACHPIT. REMOVE ANY CLOGGED SOIL, BLOCK, DEPTH (inches) ELEV.(feet) AND STONE IN LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT. 0 33 3 14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. TEST HOLE DATE: March 7, 2019 12" NO GRADE CHANGES PERFORMED BY: Ron Cadillac, Soil Evaluator L WITNESSED BY: Amy Von Hone, RS, CHO 30"Q ARE PROPOSED PERC RATE: <2'-001'/inch (B layer) SOIL SURVEY(1993): Carver coarse sand 48" GEOLOGIC MAP(1986): Harwich outwash plain deposits 12 ADS ARC 36HC HD Invert 32.59 Invert 32.05 CHAMBERS Existing pvc Proposed 72„ Use Gas Baffle Invert. 31..63 Top Units.=32.03 Proposed ® Filter Cloth I Proposed S=1 /8" eft S=1/8"/ft. 3" Max. t 1500 � Gal. _- t Inspection Port 108" 1 i Se tic Tank �(\� " Fill B layer 10yr 6/8 loamy sand C1 layer 2.5y 6/6 medium sand C2 layer 2.5y 6/2 silty clay loam _observed water _ I Invert 32.30 I i Existing 10.75" t I *Official Adjustment is 0.0 Using j 1 6 stone or compact Invert 31.80 Invert 31.60 30.7 AIW 230 ---This did not work well t I I I Proposed Proposed 5 Bottom at 154 Capt Small Nearby t I ' 1 I 519 25'-,I HGW=25.7 t 1 1 t t I l 1 < Use 1.4' Adjustment from Feb. 2019, Zone B I DESIGN DATA Mash29 (1500' South)* Observed Water=24.3 BEDROOMS: 3 LEACH AREA GARBAGE GRINDER: _ __- -- No REQUIRED CAPACITY: 330 GPD USE 12 ADS ARC 36HC CHAMBERS EXISTING SEPTIC TANK: 1000 GAL. IN TWO TRENCHES 30' X 34.5" X EFFECTIVE LEACHING AREA: 467.4 SF 10.75" DEEP, AS SHOWN. 7.79 SF/LF X 5'/UNIT=38.95 S.F/UNIT 12 UNITS X 38.95 SF/UNIT=467.4 SF(EFFECTIVE) DESIGN CAPACITY: 345 GPD [(467.4 SF) X .74 GPD/SF] Permit vafid for REPAIR OF' SEI"I'IC..Sti'ti"1'1?Nl> ONLY, due to State and Local septic wiriances. Board of Vealth review and aliproval is required for any future additionsfrenocations/,ifterations to sewage facilities anillor structures/ifwelling. Yarmouth Health De.pattinent THIS PLAN IS A VALID COPY ONLY IF IT BEARS AN ORI'''Ir''"�E1,RED S -TAMP /AND SIGNATURE. ZH OF H/,4ss9 RONALD JAMES CADILLAC co # 1060 �FcrsTER�`� VOINITAMN OF �ssgc RONALD a JAMES '> CADILLAC # 35779 S sVo�� SURVEY HEALTH AGENT APPROVAL BATH' BDRM BDRM ��I( BDRM BATH 1 BRZWAYKIT. LVRM GAR FLOOR PLAN NOT TO SCALE Large finished room in basement SITE PLAN FOR CA -ROLL J. DWINELL LOT 43, 95 PHYLLIS DRIVE, S. YARMOUTH, MA MARCH 8, 2019 SCALE: 1"=20' RONALD J. CADILLAC, PLS, RS PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 (508) 775-9700 PAGE 1 OF 1 -DATE 02019 BY R.J. CADILLAC 32.3 29.3 27.3 24.3 23.3