HomeMy WebLinkAboutReview Checklist r/0` ,:
TOWN OF YARMOUTH _
SEWAGE PLAN REVIEW CHECKLIST `"
Location: A.M. 60-
Lot/9c7/ Zone of Contribution: In Out_ Acreage__ l
� Commercial: Residential: y'
Street: �ap ,,,,6,),-0-4(1).-/
-�/
Village: .9v Floor Plan: #Bedrooms:
Owner: 511,aa7Installer:
Address: Phone:
A
Phone: ///(e-7 /7 `-
Builder: Engineer: 5ti,1or-Q A►
Address: (''''' Phone: 10 s-_95 '�j
Phone: 1-2(/ `P e
N/A " NO
1.Required#of copies received
2.Date of soils exam and percolation test not older than 2 years --^
3.4-5 ft of naturally occurring pervious material,above water table �--
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: c..._._-----
5.Water line 10 ft from septic components Var.: ,_.-/-
6.
_:/-6.Benchmark indicated and shown-NGVD if near wetlands L.----
7. Septic tank minimum 10 ft from foundation, deck Var.: - ''
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: �-
9.Leaching minimum 100 ft from wetlands Var.: c_--------
10.
_./10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: L__----
11.Tank/leaching minimum 10 ft from property line Var.: _r..--
12.System meets all other setback requirements Var.:
L_.--,--=-
13.
__13.Uses adjustment for maximum high groundwater Var.: L.__..----
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: t.._
15. System not in top or subsoil(A,B horizons)or 5'removal L._-/
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", ' "preferred C_......------
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel \-. - ..
21.No garbage disposal \__..--- "
22. System adequately sized for its intended use '
23.Minimum 6"stone or compacted below tank and dbox •••.... ✓ `
24.Manhole covers within 6"of grade,pump chamber cover to grade l.
25.Inspection port on plastic chambers/leach field ‘..____--
26.Electrical permit for pump chamber/Separate meter for duplexes L- ---
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size Com,..---
28. Septic tank/pump chamber to be factory waterproofed c
29.Vent provided if leaching below 3 feet,under driveway/parking c_..
30.Buoyancy calculations for tank/pump chamber
-
31.Engineer to inspect and certify soils: wall: commercial: ,------
32.
- .32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature ---- -".
33.H-20 loading is subject to vehicular traffic, groundwater ___.34.
34.Title V Application and permit fee,installer signature
35.Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd / �.-%
37.Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by:
6 6/03/03