1 11/30/17 Routine Operation and Maintenance Checklist for Perc-Rite Drip Dispersal system
1 701P
:y3
For review and comment: For approval: As Requested: For your use: 1
REMARKS:
cc: John M. O'Reilly, P.E., P.L.S.
Matthew J. Wrobel, E.I.T.
Client
Oakson, Inc.
From: MJW
If enclosures are not as noted,kindly notify us at once
•
ROUTINE OPERATION AND MAINTENANCE CHECKLIST
FOR
PERC-RITE DRIP DISPERSAL SYSTEM
Address: 41 Pheasant Cove Circle, Yarmouthport Date: 10/25/2018
Homeowner: Gerald McClellan
Operator: John O'Reilly, P.E., P.L.S. Lic#:17746
Job #: 8402W
HISTORICAL DATA and CURRENT READINGS
Previous flow meter reading: 8,971 Design flow: 330GPD Date of last visit: 11/30/17
Current flow meter reading: 46,382 Calculated water usage: 113.4GPD
Start-up dose rate Current dose rate
ZONE 1: 2.9 GPM GPM
ZONE 2:
ZONE 3: Unable to determine dose rate, water
ZONE 4: level too low in pump chamber.
FIELD CONDITIONS
A. Drip dispersal field: visible wet spots YES❑ NO I1
Comments:
B. Air release valves: erosion YES❑ NOEl
leakage/spraying YES 1:1 NOL
Comments:
PUMP CHAMBER/FLOAT OPERATION
A. Floats match pin lights in control panel YESD NO❑
Comments:
B. Alarm float working YESD NO❑
Comments:
C. Solids or scum present YES❑ NOD
Comments:
CONTROL PANEL
A. Switches in AUTO position YESD NO❑
Comments:
B. Peak Level light on YESD NOD
Comments:
C. Power and Run lights on (microprocessor) YESD NO❑
Comments:
PUMP and VALVE OPERATION
A. Pump in HAND position: flow meter running YESD NOD
Comments: unable to determine,water level too low in pump chamber
B. Zones 1-4 (one at a time): flow meter running YES❑ NO El
dose rate correct YES❑ NO❑
flush rate > dose rate YES❑ NOD
Comments: unable to determine,water level too low in pump chamber
C. Disc filter back flushing: working properly YES❑ NOD
Comments: unable to determine,water level too low in pump chamber
D. Disc filter inspection: excessive residue YES El NOD
cleaning required YES❑ NOD
Comments:
E. Switches returned to AUTO position YES El NO❑
Comments:
F. RESET/CYCLE START: functioning properly YESD NO ❑
Comments: unable to determine,water level too low in pump chamber
G. Hydraulic Unit: leaks, crimps, or other issues YES❑ NO❑
Comments: unable to determine,water level too low in pump chamber
SEPTIC and/or PRE-TREATMENT TANKS
Not inspected.No covers to Grade.
A. Examine and clean effluent filter: excessive residue YESD NO ❑
Comments:
B. Septic tank pumping recommended YES❑ NO ❑
1. Sludge depth:
2. Scum depth:
Comments:
C. Service pre-treatment system YESD NOD
Comments: N/A
Operator signatur License No. 17746
Comments/Observations:
On float was out of order at the time of inspection,replaced the float and all floats are now operating correctly.Flow rate was high at the time of inspection,the
reason was determined to be a cracked gasket in the zone return valve,replaced gasket.System's water level after repair was too low to be able to test new flow rate.