HomeMy WebLinkAboutReview Checklist a 3 ---i<
TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
e
Location: A.M. 2 c Lot 6 1 Zone of Contribution: In_ Out
Commercial: Residential: -------
I Street: /.2_9 Sem/ "'�
Village: / . yC�y Floor Plan: ��-C, #Bedrooms: -
Owner: 644, /e k 14 I Installer: G
Address: Phone: 3-0cF-- -7C - fo 1,
Phone: ' 4y/
Builder: Engineer: ctt...,( /�
Address: Phone: J-4 -2 g .
Phone: . / C:- ,G- ./
( / `/6 rdiir
A YES )T•
1.Required#of copies received (/
2.Date of soils exam and percolation test not older than 2 years L_----'
3.4-5 ft of naturally occurring pervious material, above water table L.---
4.
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: c.._____.----
5. Water line 10 ft from septic components Var.: _ ("C--- --
�
6.Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: (___-
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: c-
11. Tank/leaching minimum 10 ft from property line Var.: £ _/
12. System meets all other setback requirements Var.: ,,,,
13.Uses adjustment for maximum high groundwater Var.: L--- /
14.Leaching set 4-5 ft above adj. water or bottom of ar.: ( j
15. System not in top or subsoil(A,B horizons)or 5" emoval C-----'-
16.
- -/16.Proposed contours are suitable 1/4..---'-'
17. System meets slope requirements-min. 1/8", I "preferred / -
18. System meets breakout requirements PVC liner: of Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee `.._..--'
20. Sewage is under 10,000 gpd for parcel ( -/
- 21.No garbage disposal L...-----
22. System adequately sized for its intended use l._. '
23.Minimum 6"stone or compacted below tank and dbox �-/
24.Manhole covers within 6"of grade,pump chamber cover to grade
25.Inspection port on plastic chambers/leach field �,.�
26. Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed
29.Vent provided if leaching below 3 feet, under driveway/parking L-'
30. Buoyancy calculations for tank/pump chamber
31.Engineer to inspect and certify soils: wall:-ommercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature ,..------
33.
..,....-
33. H-20loading is subject to vehicular traffic,groundwater L.------
34.Title V Application and permit fee, installer signature c.-----'
35.Foundation footing min. 2 feet above adjusted ground water for new house --
36.Deed Restriction required max. #bedrooms:) - max. flow: _X2) gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: ' ) 6/03/03