Loading...
HomeMy WebLinkAboutReview Checklist a 3 ---i< TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST e Location: A.M. 2 c Lot 6 1 Zone of Contribution: In_ Out Commercial: Residential: ------- I Street: /.2_9 Sem/ "'� Village: / . yC�y Floor Plan: ��-C, #Bedrooms: - Owner: 644, /e k 14 I Installer: G Address: Phone: 3-0cF-- -7C - fo 1, Phone: ' 4y/ Builder: Engineer: ctt...,( /� Address: Phone: J-4 -2 g . Phone: . / C:- ,G- ./ ( / `/6 rdiir A YES )T• 1.Required#of copies received (/ 2.Date of soils exam and percolation test not older than 2 years L_----' 3.4-5 ft of naturally occurring pervious material, above water table L.--- 4. 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: c.._____.---- 5. Water line 10 ft from septic components Var.: _ ("C--- -- � 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: (___- 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: c- 11. Tank/leaching minimum 10 ft from property line Var.: £ _/ 12. System meets all other setback requirements Var.: ,,,, 13.Uses adjustment for maximum high groundwater Var.: L--- / 14.Leaching set 4-5 ft above adj. water or bottom of ar.: ( j 15. System not in top or subsoil(A,B horizons)or 5" emoval C-----'- 16. - -/16.Proposed contours are suitable 1/4..---'-' 17. System meets slope requirements-min. 1/8", I "preferred / - 18. System meets breakout requirements PVC liner: of Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee `.._..--' 20. Sewage is under 10,000 gpd for parcel ( -/ - 21.No garbage disposal L...----- 22. System adequately sized for its intended use l._. ' 23.Minimum 6"stone or compacted below tank and dbox �-/ 24.Manhole covers within 6"of grade,pump chamber cover to grade 25.Inspection port on plastic chambers/leach field �,.� 26. Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet, under driveway/parking L-' 30. Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall:-ommercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature ,..------ 33. ..,....- 33. H-20loading is subject to vehicular traffic,groundwater L.------ 34.Title V Application and permit fee, installer signature c.-----' 35.Foundation footing min. 2 feet above adjusted ground water for new house -- 36.Deed Restriction required max. #bedrooms:) - max. flow: _X2) gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: ' ) 6/03/03