HomeMy WebLinkAboutReview Checklist 17
IF ' l TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
e
Location: A.M. 2) Z Lot /01 Zone of Contribution: In Out_ creag „_
Commercial: Residential:
Street: 4...1.07/r° G� / ,2
Village: -4 il► of v Floor Plan: #Bedrooms: ✓� �
i Owner: C7$ 7 Installer:
Address: Phone:
Phone: fid ' . ( 4ivq.04? -44';4;*-(4. '
{
Builder: S /G /
Address: Phone: - 31' s---6 i , / ,
Phone: Z7' -- kizi � /t 1 7- -i _C-467 /
N/A 1 ,NO�
1.Required# of copies received -�
2.Date of soils exam and percolation test not older than 2 years L._---
3.4-5 ft of naturally occurring pervious material, above water table 1/4----
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: -
5.Water line 10 ft from septic components Var.: C.,
6.Benchmark indicated and shown-NGVD if near wetlands _
7. Septic tank minimum 10 ft from foundation, deck Var.: ,,___--
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: `..._
9.Leaching minimum 100 ft from wetlands Var.: '1/4......_,--
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: c...-%
11. Tank/leaching minimum 10 ft from property line Var.: L.------
12.
i12. System meets all other setback requirements Var.:
13.Uses adjustment for maximum high groundwater Var.: -
14.Leaching set 4-5 ft above adj.water or botto test, le Var.: --
15. System not in top or subsoil(A,B horizons) r 5' rI L__-------
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", ' "preferred L....--
18. System meets breakout requirements PVC liner:'h tZ all:
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel \_____--
21.
___._....21.No garbage disposal
22. System adequately sized for its intended use
23.Minimum 6"stone or compacted below tank and dbox -
24.Manhole covers within 6"of grade,pump chamber cover to grade
25.Inspection port on plastic chambers/leach field r ___-
26.Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed ....._--
29.Vent provided if leaching below 3 feet, under driveway/parking
30.Buoyancy calculations for tank/pump chamber :�_
31.Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature r
33.H-20 loading is subject to vehicular traffic, groundwater \-______-
34.
�34. Title V Application and permit fee, installer signature C-- ,-)
35.Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: �N/ 6/03/03