Loading...
HomeMy WebLinkAboutReview Checklist 7.2 tj'Ci TOWN OF YARMOUTH /c) SEWAGE PLAN REVIEW CHECKLIST ''"7- ' �- Location: A.M. Sk Lot >4..c.' Zone of Contribution: In ut Acreage Q J-9 /5#&11€S y 4'1* / Q� Commercial: Residential: Street: /� /� / Village: 444 Floor Plan: ✓ #Bedrooms: 2� Owner: Installer: 61%-a Address: Phone: Cyd "' / n Phone: C ' 7 1 ,�` ��` ` C '�/r�' Builder: Engineer: Address: Phone: �� f 7 /c(/7 Phone: _ % )/(.> N/A YES NO 1.Required# of copies received 2.Date of soils exam and percolation test not older than 2 years 3.4-5 ft of naturally occurring pervious material, above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: �-- 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: 15. System not in top or subsoil(A,B horizons)or 5'removal `rte 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", '/4"preferred 18. System meets breakout requirements PVC liner: Wall: �-- 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel L/ 21.No garbage disposal 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox 24.Manhole covers within 6"of grade,pump chamber cover to grade t 25.Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet,under driveway/parking �> 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commocial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature /,//'Z - 7 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee,installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: - max. flow: --7_,:)-(..,gpd ✓� 37.Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: , .ij 6/03/03