HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST e, `" x
Location: A.M. � Lot ' 7 Zone of Contribution: In Out age
` Commercial: Residential:
Street: ..,..244/, & /
g
Villa e: --- G�^� Floor Plan: t/ #Bedrooms:
Owner: Al/ f,611746 Installer: ,/� y r
Address: Phone:
Phone:
Builder: Engineer: ,, , -
Address: Phone: % `0'-�6/40Iiip,
Phone: -7; /066e -- e5<eilif-0)
N/A YES NO _
1.Required# of copies received l-..--'
2. Date of soils exam and percolation test not older than 2 years L----
3. 4-5 ft of naturally occurring pervious material, above water table l;,`s _
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 1/4-----
5.
s5. Water line 10 ft from septic components Var.: L__.---.
6. Benchmark indicated and shown-NGVD if near wetlands L...r
7. Septic tank minimum 10 ft from foundation, deck Var.: c..�---'
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: c --- L------4
9.Leaching minimum 100 ft from wetlands Var.: \.------
10.
/10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: t
11. Tank/leaching minimum 10 ft from property line Var.: t_....------
12. System meets all other setback requirements Var.: L.----.
13.Uses adjustment for maximum high groundwater Var.: %........---
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: L..----
15. System not in top or subsoil(A,B horizons)or 5' removal `---
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", 1/4"preferred C.....-----
18. System meets breakout requirements PVC liner: Wall:
l..__.--
19. Specified tee sizes are proper, gas baffle on outlet tee L�
20. Sewage is under 10,000 gpd for parcel L----•
21.No garbage disposal (.------
22. System adequately sized for its intended use `,..---•
23.Minimum 6"stone or compacted below tank and dbox C....----
24.Manhole covers within 6"of grade, pump chamber cover to grade L----*"
25.Inspection port on plastic chambers/leach field
(..__----
26.
_i26. Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size ,i--
28. Septic tank/pump chamber to be factory waterproofed ...-----
29.Vent provided if leaching below 3 feet,under driveway/parking ...--.--
30.Buoyancy calculations for tank/pump chamber `�..
31.Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic, groundwater L.----
34.Title V Application and permit fee, installer signature - _
35.Foundation footing min. 2 feet above adjusted ground water for new house `_
36.Deed Restriction required max. #bedrooms: max. flow: gpd - r
37. Check area lots for groundwater/Label groundwater in Assessor's Map -
Plan reviewed by: Ca>
6/03/03