HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. 96 Lot C Zone of Contribution: In Out '----A-Creage
Commercial: Residential:
Street: i /i 7 . . 4:- -
Village: :M.MrarillIlWff Floor Plan: ✓ #Bedrooms: t
Owner: G /t/-` / Installer: --�
Address: Phone: 10,,A7tiel
Phone:
Builder: Engineer: G��
7Phone:
%761,--e./A-
l c
ef-
Address: v
Phone: A� ' 7, ✓ '
N/A YES /NO
1.Required# of copies received ..
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material, above water table t..------
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: L_/
5. Water line 10 ft from septic components Var.: l/--
6.Benchmark indicated and shown-NGVD if near wetlands (...---
7.
:/7. Septic tank minimum 10 ft from foundation, deck Var.:
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: t./ -
9.Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: _....-----
11. Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.: �'.
13. Uses adjustment for maximum high groundwater Var.: (_-----
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: L .----
15. System not in top or subsoil(A,B horizons)or 5' removal k..-----
16.Proposed contours are suitable .-✓
17. System meets slope requirements-min. 1/8", 1/4"preferred ��
•
18. System meets breakout requirements PVC liner: Wall: (.......---
19. Specified tee sizes are proper, gas baffle on outlet tee L-----
20. Sewage is under 10,000 gpd for parcel L...---'
21.No garbage disposal
22. System adequately sized for its intended use �...-----
23.Minimum 6" stone or compacted below tank and dbox t.-----
24.Manhole covers within 6" of grade,pump chamber cover to grade t------
25.Inspection port on plastic chambers/leach field 4...------
26.Electrical permit for pump chamber/Separate meter for duplexes `.�
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed `----•
29.Vent provided if leaching below 3 feet,under driveway/parking �-----
•
30.Buoyancy calculations for tank/pump chamber c-.--
31.Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature ...----
33. H-20 loading is subject to vehicular traffic, groundwater
34.Title V Application and permit fee, installer signature 0
35.Foundation footing min. 2 feet above adjusted ground water for new house k--/--
36.Deed Restriction required max. #bedrooms: max. flow: gpd L__'
37.Check area lots for groundwater/Label groundwater in Assessor's Map `�
Plan reviewed by: 6/03/03