HomeMy WebLinkAboutReview Checklist ,� r I
TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. 4L Lot 9 2- Zone of Contribution: In Out ge
�� k•.1-,/"(
Commercial: Residential:L----r
Street:
Village: -k-ti Oji. Floor Plan: (./ #Bedrooms: 3
Owner: 7" c q iyc'>7 Installer: i7 1
Address: Phone: 47 p-- - '- C f 3
Phone:
Builder: ��.111,\ Engineer: lJ.A ' r 2
Address: Phone: 9� " .
Phone: 4-DP r'>-2_ -/ -3C2- 461,f/ 7G45t =.
--�` /l 1 /1, f/f SKr" G e ',
N/A YES NO
1.Required#of copies received (...m.----_-7-
2.
�_��
2.Date of soils exam and percolation test not older than 2 years L.. _
3.4-5 ft of naturally occurring pervious mitei-ial, above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: L-----
5. Water line 10 ft from septic components Var.: (`.._.
6. Benchmark indicated and shown-NGVD if near wetlands s..._.-..
7. Septic tank minimum 10 ft from foundation, deck Var.: �,s
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: t ..--�
9.Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ------
11.
''11.Tank/leaching minimum 10 ft from property line Var.: �_-
12. System meets all other setback requirements Var.:
13.Uses adjustment for maximum high groundwater Var.: k....____--
14.
_,,.14.Leaching set 4-5 ft above adj. water or bottom 9f-test hole Var.: `.___r
15. System not in top or subsoil(A,B horizons) o(5'5' remov �%
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", 'A"preferred \-_____-
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee t..---
20. Sewage is under 10,000 gpd for parcel (_
21.No garbage disposal L_____.--
22. System adequately sized for its intended use %,-J
' 23.Minimum 6"stone or compacted below tank and dbox �.__.__-
24.Manhole covers within 6"of grade,pump chamber cover to grade k....._----
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes --
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size ,--- '
28. Septic tank/pump chamber to be factory waterproofed .
29.Vent provided if leaching below 3 feet, under driveway/parking (L.G'r .__.
30. Buoyancy calculations for tank/pump chamber y/
31. Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic, groundwater
_ 34. Title V Application and permit fee, installer sigrjturec7
35.Foundation footingmin. 2 feet above
adjustedground water for new house �.,.
36.Deed Restriction required max. #bedrooms: max. flow: gpd `-------
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: (6 .2'i i