Loading...
HomeMy WebLinkAboutReview Checklist r -2' / rC TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 1 Lot *2#7 Zone of Contribution: In_ Out_Acreage Commercial: Residential: Street: f)-- T(rze 0(Qn /ay Village: (,%/ ttet Floor Plan: #Bedrooms: 2 Owner: Installer: 6 c-- -A. Address: 17 Phone: r% - 4---17 -OG S-73 Phone: Builder: Engineer: 2Us/ o Address: Phone: +1- 7? / Phone: f 6x -e' %_ N/A YES NO 1.Required#of copies received ``"`---" 2.Date of soils exam and percolation test not older than 2 years (.--------- 3.4-5 ft of naturally occurring pervious material, above water table ,--_---- 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: .. ------ 6.Benchmark indicated and shown-NGVD if near wetlands `.-----" 7. Septic tank minimum 10 ft from foundation, deck Var.: Z.-------- 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 1.--------- 9.Leaching minimum 100 ft from wetlands Var.: _________ 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: �--'� 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: 1/4....----- 14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 15. System not in top or subsoil(A,B horizons)or 5'removal ,............-- 16. �16.Proposed contours are suitable `--- -" 17. System meets slope requirements-min. 1/8", ' "preferred `-- 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee -_--- 20. Sewage is under 10,000 gpd for parcel -- 21.No garbage disposal ....:.--- Q2. =22. System adequately sized for its intended use ___.----- 23.Minimum 6"stone or compacted below tank and dbox ,...------- _74.Manhole covers within 6"of grade,pump chamber cover to grade ___--A 25.Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes .--- --' 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size .------ 28.Septic tank/pump chamber to be factory waterproofed -------- 29.Vent provided if leaching below 3 feet,under driveway/parking - ; 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: ✓ ��� 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater . .- --- 34.Title V Application and permit fee, installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house ,----- 36.Deed Restriction required max. #bedrooms: max. flow: gpd _ - 37.Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: ' 6/03/03