HomeMy WebLinkAboutEngineered Plans - 2018Permit valid for RFPA1IR OF SE11 "f'IC SYS -1 -LM
QNLY, due to Stateand Local septic variances.
Boord.of Wafth review and approval is required for
aaty, future additions/.rcnavations,'aIterations to
sewage facifrties and/or s(ructicrestdwelling.
Yfi1.rmouth H�alili m artrTrent/�
,AID",W)VED
14 1-n l
11�1�a1►ftal�lu11�:4�► /I
UNDED W/4' STONE
97.39
X"
o
97,991
97,34
LOT 5p'
10,953 tS.
X7.58PROPOSE
SEPTIC TANK
98,30 6�
0�98,74 ��
0 0 � ��
P7, j3/
B _ . /
0
9,1185
1
or
7,8 I
O / • ' SPIKE
99.42
N
S,4,76 ,70
ENTRY ENTRY HALL
LIVING [BAT BEDROOM
KITCHEN ROOM
CAR
PORT DN HALL J ----
DINING
ROOM
ENTRY BEDROOM BEDROOM
FLOOR PLAN
LIQ
EXISTING CESSPOOLS
TO BE PUMPED, FILLED
j WITH SAND AND ABANDONED
YD, v�
S),
23s. 100,21 O
9
x 100,38
CB
00.61 100,16
HOUSE(J46)
TOF=100.2f_-
DECK
97.4'9
r \\
s�
s
�015.27�x 97,76
900 \� 0e,
X5,27
--56--
EXISTING CONTOUR
X 100.98
EXISTING SPOT GRADE
—NI
EXISTING WATER SERVICE
—G
EXISTING GAS SERVICE
—6.H-
OVERHEAD WIRES
TEST PIT
PARCEL ID: 70-71 jUL 2
BENCHMARK
LEGEND
:�.
EXISTING CESSPOOL
TO BE PUMPED, FILLED
X
99 5 C5 !� WITH SAND AND ABANDONED
r -
J ,69 �
� ���� OF Mgss9c
EXISTING CESSPOOL
o PETER T. s
TO BE PUMPED, FILLED
WITH SAND AND ABANDONED MEN EEc-> CIVIL
N
No. 35109
NOT TO SCALE
GENERAL NOTES:
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGU TIONS EXC T AS REQUESTED BELOW:
–310 CMR 15.405(1)(b): f
1) A 3' variance to the 3' maximum cover requirement, for up to
6' of max. cover. S.A.S. shall be H-20 and vented.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON AN ASSIGNED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S.
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
DIRECTED BY THE APPROVING AUTHORITIES.
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
INSPECTED BY HEALTH DEPARTMENT PRIOR TO BACKFILL.
13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND
IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY.
R£G/SZERc�
RCEI
D
S10
PARCEL ID: 70-71 jUL 2
18
PROPOSED
SEPTIC SYSTEM UPGRADE IP
P7.
46 HIGHBANK ROAD, SOUTH YARMOUTH, MA
Prepared for: Paulette Burke, 46 Highbank Road, So. Yarmouth, MA 02664
OWNER OF RECORD
BURKE, GLENROY
Engineering by:
Surveyring by: SCALE DRAWN JOB. NO.
"=20'
McBEAN–BURKE, PAULETTE
Engineering Works, Inc.
12 West Crossfield Road
JC Engineering, Inc. 1 P.T.M. 141-18
2854 Cranberry Hwy.
46 HIGHBANK ROAD
Forestdale, MA 02644
E.Warehom, MA 02538 DATE CHECKED SHEET NO.
SOUTH YARMOUTH, MA 02664
(508) 477-5313
(508) 273-0377 6/4/18 P.T.M. 1 Of 2
I
NOTE: TO PREVENT BREAKOUT, FINAL GRADE
DECK
SHALL NOT BE AT, OR BELOW, EL.=93.5
FOR A DISTANCE OF 15' FROM THE EDGE
SEPTIC TAN K PROPOSED D -BOX
OF THE PROI�OSED S.A.S.
INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER
OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE PROPOSED S.A.S.
INSTALL RISER &COVER OVER EACH CHAMBER ANDiEXISTIIVG
/
T.O.F.=100.2± SET
TO 3" OF F.G. TO SERVE AS INSPECTION PORT
/ /H0USE(#46)11
F . EL.=99.5±F.G. EL.=99.0± INSTALL CHARCOAL VENT
F.G. EL.=99.3± F.G. EL. =99.2± IF COVER EXCEEDS 36"
MAINTAIN 2% SLOPE OVER S.A.S.
/ r TOF=100.2±
♦ J j'
L1=40'
/ ,/
L2=10' L=15 L=13'.
® SCH (MIN.) CSD SCH4 (MIN.) ®S=1% (MIN.)
4"SCH40 PVC 4'SCH40 PVC 4"SCH40 PVC
2" LAYER OF 1/8" TO 1/2"
DOUBLE WASHED STONE
to"I s"
(OR APPROVED FILTER FABRIC)
to
96.0 48" LIQUID
0000®®o
aaaaaaa --3/4" TO 1-1 /2" DOUBLE
N
raj b tl b
N Dc• 4J
LEVEL ADD PROPOSED 4'
GAS BAFFLE INV.=94.72 1) BOX INV.=94.55
INV.=95.75
4.8' 4' WASHED STONE
EFFECTIVE WIDTH = 12.8
Cr
M �
3 OUTLETS INV.=93.00
PROPOSED SEPTIC TANK H-20 RATED 2_%0
k1F
GALLON LEACHING CHAMBERS
?
SURRC)UNDED
WITH STONE AS SHOWN
PROP.
ERIOR PLUMBING TO PROVIDE TWO NEW
H-20 RATED
S.A.S.
T HOUSE, AT, ORABOVE, THE FOLLOWING:
SEWER OUTLET 1, INV.=96.20 TOP CONIC. ELEV.=94.1±
__772
SEWER OUTLET 2, INV.=96.70 BREAKOUT ELEV.=93.50
NOTES: INV. ELEV.=93.00
as®®
amomo
®a®a®®®®®
A-
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPES & a®aa®®®aa®a
S.A.S. LAYOUT
INVERTS EXITING HOUSE, PRIOR TO INSTALLATION. BOTTOM ELEV.=91.00
4' 2 x 8.5'=27.0' 4'
2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND TRUE
TO GRADE ON A MECHANICALLY COMPACTED 6" CRUSHED 4' OF NATURALLY OCCURRING
PERVIOUS MATERIAL
EFFECTIVE LENGTH 12.8'
-
STONE BASE, AS SPECIFIED 310 CMR 15.405(2). 5' (MIN.) ABOVE G.W.
3) INSTALL INLET & OUTLET TEES AS REQUIRED.
4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE BOTTOM OF TEST PIT, EL.=87.1 =
LEACHING !SYSTEM SECTION
® ® ® ® 0 U E3 Ea E3
AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL.
® U ® ® ® ® ® ® ® ® ® 37"
5) USE OF THE EXISTING SEPTIC TANK IS SUBJECT TO
®
THE APPROVAL OF THE FALMOUTH BOARD OF HEALTH
N j Ea
® U®®®®®®® ® Ea
OR ITS AGENT. SEPTIC SYSTEM PROFILE
Z
-
102"
SOIL LOG
DESIGN CRITERIA
4" KNOCKOUT
DATE: APRIL 19, 2018
NUMBER OF BEDROOMS: 3
SOIL EVALUATOR: PETER McENTEE PE(SE#1542)
20" DIA. COVER
SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 GPD/SF)
WITNESS: AMY VON HONE RS HEALTH AGENT
/
ELEV. TP DEPTH
4" KNOCKOUT 4" KNOCKOUT 58"
0
DESIGN PERCOLATION RATE: <2 MIN/IN
F 0"
99
DAILY FLOW: 330 GPD
FILL
DESIGN FLOW: 330 GPD
GARBAGE GRINDER: NO -not allowed with design
94.6 57"
Ab
j', 4" KNOCKOUT
V 2
LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF
LOAMY SAND
1OYR14/2500
-
GALLON CAPACITY, H -20 LOADING
74 GPD/SF
931 B 72"
PERC
CHAMBERS
PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY (H-10)
LOAMY' SAND 66"/84"
PROPOSED D -BOX: 1 INLET, 3 OUTLET (MINIMUM), H-20 RATED
10YR ,5/8
N.T.S.
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
92.0Ss
O
USE 2-500 GALLON LEACHING CHAMBERS IN SERIES
4.6 HIGHBANK ROAD, SOUTH YARMOUTH, IAA
SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES
MED.I SAND
SIDEWALL AREA: 2(12.8' + 25.0') X 2 = 151.2 S.F.
2.5Y 6/6
Prepared for: Paulette Burke, 46 Highbank Road, So. Yarmouth, MA 02664
BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F.
Engineering by:
Surveyring by:
SCALE
DRAWN
JOB. NO.
TOTAL AREA:........................................I... 471.2 S.F.
""' ' ' " ' ' '
87.1 147 ,
ER ENCOUNTERED
E+igineering Works, Inc.
JC Engineering, Inc.
N.T.S.
P.T.M.
142-18
DATE
CHECKED
SHEET N0.
DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.7 GPD
NO GROUNDWATER
PERC RATE <2 MIN./INCH
1,e. West Crossfield Road
Forestdole, MA 02644
2854 Cranberry Hwy.
E.Worehom, MA 02538
(508) 477-5313
(508) 273-0377
6/4/18
P.T.M.
2 Of 2