HomeMy WebLinkAboutReview Checklist 1
,-26,i7
111W-
rAs
TOWN OF YARMOUTH
r
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. 5/ Lot (0 Zone of Contribution: In Out c-----A-c-reage °
Commercial: Residential:
Street: _lc Z-
Villa e: Floor Plan: #Bedrooms:
Village: ` �
Owner: (M Installer:
Address: Phone:
Phone: 777- - 2- b //Q) 2-
Builder: 52.y4.1.-/ Engineer: AC 647,-0
Address: Phone: C6rQ'- 7 >C"
Phone:
N/A YES NO
1.Required#of copies received (.....-------
2.
./2.Date of soils exam and percolation test not older than 2 years k.....------
3.
-f3.4-5 ft of naturally occurring pervious material, above water table (------
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: t....------
5.
5.Water line 10 ft from septic components Var.: L....------
6.Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: (.....-------
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: L.:,-
9.Leaching minimum 100 ft from wetlands Var.: t.--
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.: t:. - --'
12. System meets all other setback requirements Var.: -- '
13.Uses adjustment for maximum high groundwater Var.: �----
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: t,,,/
15. System not in top or subsoil(A,B horizons)or 5'removal „..-----
16.
-16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", 1/4"preferred
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee ...-
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal
22. System adequately sized for its intended use L.----
23.
..23.Minimum 6"stone or compacted below tank and dbox L.-----' .
24.Manhole covers within 6"of grade,pump chamber cover to grade (.....------
25.Inspection port on plastic chambers/leach field
26.Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed
29.Vent provided if leaching below 3 feet,under driveway/parking ___ ----
30.Buoyancy calculations for tank/pump chamber
_ 31.Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic, groundwater �,/5/'
34.Title V Application and permit fee, installer signature
35.Foundation footing min. 2 feet above adjusted ground water for new house „_,_._..-
36.Deed Restriction required max. #bedrooms: max.flow: gpd -
37.Check area lots for groundwater/Label groundwater in Assessor's Map .--'' '
Plan reviewed by: 6/03/03