HomeMy WebLinkAboutReview Checklist (c r/ TOWN OF YARMOUTH
• SEWAGE PLAN REVIEW CHECKLIST M/t S
Location: A.M. C ( Lot �y/ Zone of Contribution: In'Out Acreage
• (� �J4 Jf // Commerci. • R'd en,'
Street: 1j rel__7
Village: i Floor Plan: #Be. ooms: ,(/Ai�
Owner: 7i� oe-g Installer:
Address: Phone:
Phone:
Builder: Engineer: 9 ,` /
Address: Phone: . -fF ' 94
Phone: ._ 2 l; r ' i / ti
N/A YES NO
1.Required# of copies received �/
2. Date of soils exam and percolation test not older than 2 years (..- ----
3. 4-5
,/3. 4-5 ft of naturally occurring pervious material, above water table L.-----
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic components Var.: l-----
6.
/6.Benchmark indicated and shown-NGVD if near wetlands L,_o
7. Septic tank minimum 10 ft from foundation, deck Var.: t_..-----
8.
_e8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: t._.---
9.Leaching minimum 100 ft from wetlands Var.:
-
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ....----
11. Tank/leaching minimum 10 ft from property line Var.: L`- _
12. System meets all other setback requirements Var.:
"...----
13.
13.Uses adjustment for maximum high groundwater Var.: �__.----
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: _.
15. System not in top or subsoil(A,B horizons)or 5' removal L____
16.Proposed contours are suitable �_._
17. System meets slope requirements-min. 1/8", ' "preferred t-_--
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal ‘........--
-22.
f_22. System adequately sized for its intended use t._-----
123.
.1123.Minimum 6" stone or compacted below tank and dbox t.._-
24.Manhole covers within 6" of grade,pump chamber cover to grade
25. Inspection port on plastic chambers/leach field \--!,
26. Electrical permit for pump chamber/Separate meter for duplexes -_-----
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size -.----
28. Septic tank/pump chamber to be factory waterproofed
29.Vent provided if leaching below 3 feet,under driveway/parking
30.Buoyancy calculations for tank/pump chamber .-
31.Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature �,/
33.H-20 loading is subject to vehicular traffic, groundwater ......----
34.
!34.Title V Application and permit fee, installer signature
35.Foundation footing min. 2 feet above adjusted ground water for new house 1/4.------
36. Deed Restriction required max. #bedrooms:2_ max. flow:._h) gpd 1/4....----
37.
i37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: (✓ 6/03/03