Loading...
HomeMy WebLinkAboutReview Checklist 3'z9-7l TOWN OF YARMOUTH • SEWAGE PLAN REVIEW CHECKLIST Location: A.M. /49-'1. Lot iC Zone of Contribution: In, cut Acreage Commercial: Residential: �y Street: ,2CZ �L � / /Village: Floor Plan: e. #Bedrooms: CO Owner: (�e�3,(1)7 G�)04/19 0 Installer: C&LireVie.e../ Address: Phone: g rJjOe_aat 2//4. Phone: , Builder: Engineer: Address: ..7-- - Phone:- - <' �5.11e - Phone: /1 l� / &t7qh. N/A YES NO 1.Required# of copies received t 2. Date of soils exam and percolation test not older than 2 years t.....-''' 3. 4-5 ft of naturally occurring pervious material, above water table L-,,,---"- 4. e4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: L./ 5. Water line 10 ft from septic components Var.: (....-/' 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: _ 1----"- 8. /8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: L-.----- 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: f - 11. Tank/leaching minimum 10 ft from property line Var.: .....------ 12. System meets all other setback requirements Var.: lei' 13. Uses adjustment for maximum high groundwater Var.: i...----- 14. l14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: C.--- 15. System not in top or subsoil(A,B horizons) or 5' removal L----- 16. f16.Proposed contours are suitable t--s-' 17. System meets slope requirements-min. 1/8", 'A"preferred t.-----# 18. System meets breakout requirements PVC liner: Wall: t..---' 19. Specified tee sizes are proper, gas baffle on outlet tee L_/ 20. Sewage is under 10,000 gpd for parcel Lam' _ 21.No garbage disposal (/ 22. System adequately sized for its intended use L---# 23.Minimum 6"stone or compacted below tank and dbox L----". 24.Manhole covers within 6" of grade,pump chamber cover to grade Lam/ 25. Inspection port on plastic chambers/leach field l.../. 26.Electrical permit for pump chamber/Separate meter for duplexes c.------ 27. . f27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size `-/' 28. Septic tank/pump chamber to be factory waterproofed .......---- 29. l29.Vent provided if leaching below 3 feet, under driveway/parking �/' 30.Buoyancy calculations for tank/pump chamber ..---- 31.Engineer to inspect and certify soils: wall: commercial: \------ 32. f32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature moi` 33.H-20 loading is subject to vehicular traffic, groundwater L1 34.Title V Application and permit fee, installer signature - 35.Foundation footing min. 2 feet above adjusted ground water for new house ,----- 36.Deed Restriction required max. #bedrooms: max. flow: gpd / - ./--- 37. 37.Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: 6/03/03