HomeMy WebLinkAboutReview Checklist 3'z9-7l
TOWN OF YARMOUTH
• SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. /49-'1. Lot iC Zone of Contribution: In, cut Acreage
Commercial: Residential: �y
Street: ,2CZ �L � / /Village: Floor Plan: e. #Bedrooms: CO
Owner: (�e�3,(1)7
G�)04/19 0 Installer: C&LireVie.e../
Address: Phone: g rJjOe_aat
2//4.
Phone:
,
Builder: Engineer:
Address: ..7-- - Phone:- - <' �5.11e -
Phone: /1 l� / &t7qh.
N/A YES NO
1.Required# of copies received t
2. Date of soils exam and percolation test not older than 2 years t.....-'''
3. 4-5 ft of naturally occurring pervious material, above water table L-,,,---"-
4.
e4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: L./
5. Water line 10 ft from septic components Var.: (....-/'
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: _ 1----"-
8.
/8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.: L-.-----
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: f -
11. Tank/leaching minimum 10 ft from property line Var.: .....------
12. System meets all other setback requirements Var.: lei'
13. Uses adjustment for maximum high groundwater Var.: i...-----
14.
l14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: C.---
15. System not in top or subsoil(A,B horizons) or 5' removal L-----
16.
f16.Proposed contours are suitable t--s-'
17. System meets slope requirements-min. 1/8", 'A"preferred t.-----#
18. System meets breakout requirements PVC liner: Wall: t..---'
19. Specified tee sizes are proper, gas baffle on outlet tee L_/
20. Sewage is under 10,000 gpd for parcel Lam'
_ 21.No garbage disposal (/
22. System adequately sized for its intended use L---#
23.Minimum 6"stone or compacted below tank and dbox L----".
24.Manhole covers within 6" of grade,pump chamber cover to grade Lam/
25. Inspection port on plastic chambers/leach field l.../.
26.Electrical permit for pump chamber/Separate meter for duplexes c.------
27.
. f27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size `-/'
28. Septic tank/pump chamber to be factory waterproofed .......----
29.
l29.Vent provided if leaching below 3 feet, under driveway/parking �/'
30.Buoyancy calculations for tank/pump chamber ..----
31.Engineer to inspect and certify soils: wall: commercial: \------
32.
f32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature moi`
33.H-20 loading is subject to vehicular traffic, groundwater L1
34.Title V Application and permit fee, installer signature -
35.Foundation footing min. 2 feet above adjusted ground water for new house ,-----
36.Deed Restriction required max. #bedrooms: max. flow: gpd / -
./---
37.
37.Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: 6/03/03