Loading...
2019 Apr 09 - Sign Off Transmittal, Floor Plans - Finish 2nd Floor - Increase to 3BR oto TOWN OF YARMOUTH HEALTH DEPARTMENT o ; PERMIT APP ,ICATION SIGN OFF TRANSMITTAL SHEET To be completed by Applicant: Building Site Location: <3 m P Proposed Improvement: i tv ` 614. Fvz L " F-4004. — 73 Ff-rht c4 BE D RjQ L Applicant: L,O _ iA S Tel. No.: Y01-6,E6 Address: (f YVl9` Sr; Date Filed: "7 i **Ifyou would like e-mail notification ofsign yyoo�ff please provide e-mail address: Owner Name: cr."-AVLty( fit/.bPa4.t.s Owner Address: 3'') /Yi P ' Owner Tel. No.: 'Y 2 f 606-/oe 7 RESIDENTIAL AND/OR COMMERCIAL BUILDING HEALTH DEPARTMENT: Determines Compliance to State and Town Regulations; i.e., Requirements For Septage Disposal and other Public Health Activities. Please submit three (3) copies of plans,to include: (1.) Site Plan showing existing buildings,water line location, and septic system location; (2.) Floor plan labeling ALL rooms within building (all existing and proposed)— Note:Floor plans not required for decks,sheds, windows,roofing; (3.) If necessary, Title 5 application signed by licensed installer with fee. REVIEWED BY: DATE: // PLEASE NOTE COMMENTS/CONRITIONS: VGA _ ? (�-e d 15e v J LINE SET BACK FIRE-RATING/SEPARATION REQUIRED UNLESS SPECIFIED OTHERWISE 0 I CN N DUCT TIGHTNESS AND BLOWER DOOR TESTING ON-SITE BY BUILDER AND CERTIFIED BY STATE %ml BUILDER IS RESPONSIBLE TO NOTE: STRUCTURE DEPICTED Al IHIS SITE ADDRESS 10 HE SUPPLY AND INSTALL GAS LINE IDEMOLISHED BY BUILDER AND REPLACED WITH THIS HOUSE 23'-1 1/2" 32'-0" CODES: MA SINGLE & TWO FAMILY DWELLING CODE (780 CMR) -9TH EDITION MA FUEL/GAS/PLUMBING CODE 2009 INTERNATIONAL MECHANICAL CODE W/AMENDMENTS 2015 INTERNATIONAL ENERGY CONSERVATION CODE W/ AMENDMENTS 2017 NATIONAL ELECTRICAL CODE W/ MA AMENDMENTS NOTES: 1. *- DENOTES ADDITIONAL COLUMN IN BASEMENT 2. 2X6 EXTERIOR WALLS 16" O -C. 3. 2X3 MARRIAGE WALLS 16" O.C. 4. ROOF RAFTERS 16" O.C. num: c-cX I u SPSS -- SPF #2 num: c-cx i v SPSS I X W O O I Th -1-2x6 FS 1-2x6 JS STUD GRADE PFS Corporation Northeast Region APPROVED H Raup - 3 1/31/18 Approval limited to Factory Built Portion 3-31b C4fmlo 6T—, RECEIVED APR 09 2019 C `t L i) -t HEALTH AEPT *5/8" CEILING GYP MECHANICALLY FASTENED* CHRiSO 1/30/2018 10: 41: 26 AM 5. 8'-0" CLG. 9'. BUILDER IS RESPONSIBLE FOR PROVIDING A PROPERLY 6. STAIRS TO BE 81/4" RISERS AND 9" TREADS. SIZED HEATING SYSTEM TO COVER A BTU LOSS OF 37500 7. CEILING BEAM_LIVING/KiTCHEN/IDINING TO BE: (1) Ll/2"-x 18" LVL;(PER'UNIT), y - "10 PBR - DENOTES PER BUILDER'S REQUEST 8. HEAT LOSS WAS CALCULATED IN ACCORDANCE W/RESCHECK INSULATION` VALUES 11• 00 UJ N N i' w W HDR.2-2x6 SPF #2 2852 V -,�M r7 *TEMPERED* SPF SPF #2 24210 1 2" FUTURE VENADON ENT HDR: 2-24 DATA PLATE, STATE LABEL, 3" ELECT ONDUIT 24210 ROUP PFS UMTS AEL C do OB' o 0 o .— U 10'-0" N 7'-0 3/4" W2439 "��' 39 W2439 W1539 W3021 i 319 0 J a 1--__j - - U) LL z \ 39 PBR BIR o Q w z W W m 0 m d n (� ao �� SBI L36 l DWS BD15 I — e'Ar 812 -4D a m BEDROOM #2 x � I N I > �, 5 __J O� C== -� 3 -F 71 1/2„ q $ m O Q 2'-0 3/4" 12'-10 1/2" F -t 1/a J N Room Sq Ft: 81.53 > -_ -- o z = Z Light Req: 6.52 o a- o w I - OMIT C -TOP, SINK, vT m :�i Light Provided: 11.5 O v L` Y IAND FAUCET } Vent Req: 3.26 o f M RAISE CAB. 3/4" (na z � Vent Provided: 5.8 P.E, BATH #1 N 3 w li FOR ON—SITE FLOORING z o m SD 3 a `� KITCHEN/DINING Room Sq Ft: 148.06 3'-0 1/4" 2'-7, REFER RECESS Light Reg: 11.84 210 216 LIN 216 N N Light Provided: 37.2 3 m 4"x "x 72" Vent Req: 5.92 210 Vent Provided: 19.1 3'-7" 3'-7" 3" DRAIN & 4-3/4" SUPP. T I CLO HALL moa STUBBED TO ATTIC M i CLO P.E. j 216 HDR AS HIGH AS POSS (DROP 6" MIN_) cn 210 216 — — — Sc — — — — DROPPED HDR -- 1-2x3 FS S_0" 2-2x3 JS 15'-3" SD — -- —----- P. E. P.E. -------- ------ : BEDROOM #1 LIVING ROOM z Room Sq Ft: 134 Roam Sq Ft:_ 170.29 Light Req: 10.72 i } Light Req: 13.62 0 Li Light Provided: 9 23 m Light Provided: 23 I Vent Req: 5.36 ; 0Ul z Vent Req: 6.81 N Vent Provided: 11.6 w i = Vent Provided: 31.3 ¢r w O LANDING A 12'-0" 18'-7 1/2" 2852-2 7'-0" "1 18'-6" 310 -EXT 2852-2 25'-0" 32'-0" CODES: MA SINGLE & TWO FAMILY DWELLING CODE (780 CMR) -9TH EDITION MA FUEL/GAS/PLUMBING CODE 2009 INTERNATIONAL MECHANICAL CODE W/AMENDMENTS 2015 INTERNATIONAL ENERGY CONSERVATION CODE W/ AMENDMENTS 2017 NATIONAL ELECTRICAL CODE W/ MA AMENDMENTS NOTES: 1. *- DENOTES ADDITIONAL COLUMN IN BASEMENT 2. 2X6 EXTERIOR WALLS 16" O -C. 3. 2X3 MARRIAGE WALLS 16" O.C. 4. ROOF RAFTERS 16" O.C. num: c-cX I u SPSS -- SPF #2 num: c-cx i v SPSS I X W O O I Th -1-2x6 FS 1-2x6 JS STUD GRADE PFS Corporation Northeast Region APPROVED H Raup - 3 1/31/18 Approval limited to Factory Built Portion 3-31b C4fmlo 6T—, RECEIVED APR 09 2019 C `t L i) -t HEALTH AEPT *5/8" CEILING GYP MECHANICALLY FASTENED* CHRiSO 1/30/2018 10: 41: 26 AM 5. 8'-0" CLG. 9'. BUILDER IS RESPONSIBLE FOR PROVIDING A PROPERLY 6. STAIRS TO BE 81/4" RISERS AND 9" TREADS. SIZED HEATING SYSTEM TO COVER A BTU LOSS OF 37500 7. CEILING BEAM_LIVING/KiTCHEN/IDINING TO BE: (1) Ll/2"-x 18" LVL;(PER'UNIT), y - "10 PBR - DENOTES PER BUILDER'S REQUEST 8. HEAT LOSS WAS CALCULATED IN ACCORDANCE W/RESCHECK INSULATION` VALUES 11• 00 UJ N N i' w W L.LJ Q V -,�M r7 D J CO < o 0 o .— U Y C rn m = ce o N o 0 0 J a 1--__j - - U) LL z (3 co o Q w z W W m 0 m 10007 co s r7 z a m J q $ m O Q J J p > o z = Z o a- < vT :�i :�i Q O w w } o f (na z � W W z o m 3 0 z .0- L.LJ Q V -,�M r7 Nr �nf2 /J'� QLL_ Q OD n U Y C rn m = ce o w O COO 0 J a 1--__j - - U) LL LLJ (3 r o O w z W W J O � � �j 10007 co s N to a m Don 3A c� < 0 I N CD 32'-0" 3" RADON VENT — — — — — — — — 2" FUTURE VENT I 31'-0" �C)V6)S C-2�> �Ro�oSEc� °c 142/6 N M o p I i� III O �) III III II II II III III II II II III A35-- -_�-_ — — — — --- A35 4'-11 1/4" SPF #2 x I 3'-0" III III II I �) ; (w �In uI� Of VIII MI }III III} aul IIla I ( 2842 — — Z-35 2'-4 1/2" 4'-7 1/2" 4'—g" BONUS ROOM Room Sq Ft: 423.3 Light Req: 33.86 Light Provided: 39 Vent Req: 16.93 Vent Provided: 20.52 III II II II III III II III II III ------- A35—--�1� ------ A35 i II I II 4'-11 1/2" I 2-2x6 SPF #2 I nl i ul III I � III L'-1 I ILi <il l < �) 3'— 9 � 7 }III I VIII Illy 2842 (I 2'— 4 1/2" 4'-9" 4'-7 1/2" PROPOSED SECOND FLOOR DRAWINGS ARE TO BE USED AS A GUIDE ONLY. BEAM SIZE IS BASED ON SUGGESTED PLAN SHOWN. MANUFACTURER WILL NOT ASSUME ANY LIABILITY OR RESPONSIBLE FOR ALTERED CONSTRUCTION OF SECOND FLOOR LAYOUT. NOTES: 1. * - DENOTES ADDITIONAL COLUMN IN BASEMENT 5. 9. 2. 2X6 EXTERIOR WALLS 16" O.C. 6. 10. 3. ROOF RAFTERS 16" O.C. 7. 11. 4. 8. 12. w qrJ (n 0 I N CHRISO PFS Corporation Northeast Region APPROVED H Raup - 3 1/31/18 Approval limited to Factory Built Portion REC F. I AAA 0 9 2019 Icy-)nr HEALTH DEPT. :�D Cpm F 5-r, 1/30/2018 10: 41: 26 AM z 00 F- v WC4FM cn Q � co � m� w 2EwL^ , Nm cy ZvZi W O X o nMaLE V) } N z � Z o n O zco w Q 0 o c N C OD c N w L) J M o O o� Q J � o 0 z z co Q M (-D�m z� v zw I� J_ n Q W J J 0 = > o : = z n J Q<0" W i— 0 (n W z W WN a o � m o z QC4Fj W J F- v WC4FM � n Q m� U� 2EwL^ U Li Nm O ZvZi W O X �J �Lt nMaLE V) } z o n O zco I U) o c N C OD c i m o M3 o 00100 3,02 c� a a