HomeMy WebLinkAboutEngineered Plans - 2019W
Z
J
O
X0
12 WHISTLER LANE .,''95.57' X i :' ..
134-29 #15 CONSERVATION DRIVE 93.21' X �b\e "'t" 97
town water 134-27 j rd I
o town water �u�de<9
O p c(D CP (ft
t
4,
i.
SITE
"YARMOUTHPORT"
it CIRCUIT
GENERAL NOTES
1. ADDRESS: 3 CONSERVATION DRIVE, YARMOUTH
2. ASSESSOR'S NUMBER: MAP 134 PARCEL 26
3. DEVELOPER'S LOT: LOT #31
4. TOPOGRAPHIC INFORMATION WAS COMPILED FROM
AN ON THE GROUND INSTRUMENT SURVEY.
5. TOWN WATER IS PROVIDED TO THE SITE & SURROUNDING PROPERTIES.
6. NO WETLANDS ARE LOCATED WITHIN 150 FEET OF THE PROPOSED SAS.
7. REFERENCE PLAN: DEED BOOK 20123 PAGE 7, PLAN BOOK 271 PG 81
8. UTILITIES LOCATED BY DIGSAFE #20191306988.
9. THIS DESIGN PLAN IS TO BE UTILIZED FOR SEPTIC REPAIR PURPOSES ONLY.
10. EXISTING SEPTIC COMPONENTS LOCATED PER THE AS—BUILT ON FILE AT BOARD OF HEALTH.
LEGEND
—W—
97.96 X
••••••••••18.- .••••
161.81'
KNau
-�=
-•98
101.78' X
Existing Leach Pit
septic setback
f
DIRT ' �zo
0
Perk Test Location
98.37'
I
/
LOT 31
:'\ DRIVtWAY
a
AREA— 2 2
S 100•....-...
F. o
septic setbackP�//
:::-:::.•:;:::::•: ;TEST
,198±
.
-
100.............................................................................................................................................................................................
PROPOSED' -SAS::
:;
':;''>'`
HOLE
. .......................................
..99
98 .......................................... .............. ....................
------- 97.45------------------
2 H-10
:
500—gahchambers
9
o. :::•::•::
#1 `---
HOCKANOM "ROAD`S
SCALE.
,PLAN
1 — 20
------�.
a
with
4 ofstone. on
sides;:
PUBLIC — VARIABLE WIDTH
0.1
ON
C.B.1 FND.
100.18'
_1 .0
and
ends i n ` a 25' X
`.13' 2'
l e a
h trench .
TEST.
-:::•
;>;>
' `'
EXISTING
v
L
2
;.
D
DWELLIN
3,�
6'
IIII= �'�
F elev. 103.
1
C�
w
°°°°
°°°°°°°°°°
wood �.......�.........�
deck I �Bsmt Fl.elev.=
z
—
��o.o�
I
I I I I I i 94.94'/
w
Q7
':.
RESER
R EA V
5
TEST 9 � -• 17'
�— GAS
1 .;
00 70 :
— GAS —�._ GAS
E 0
--
U
Ln
b o H
° ° #3E
20
/l/
IV
—��j/�/_��A
— GAS
j
0 I—
0
100.12' X
o ap000000o
°o°°°O°O
1
1 1 1 1 1 1
-7.
I 0
p
J in
- ':
°O-°°o°°°O°°
TEST
Y II
, Y
HOLE
ICD
#4
99.80
96.17'
Q
z>
:.::::; ::::::::;::;::::
..:.:.: `.:t :::: `D
97.09,
RElf
IVE
... U
...99.65'
:: P.K.ail set
.....:XK
99.63'
i.
SITE
"YARMOUTHPORT"
it CIRCUIT
GENERAL NOTES
1. ADDRESS: 3 CONSERVATION DRIVE, YARMOUTH
2. ASSESSOR'S NUMBER: MAP 134 PARCEL 26
3. DEVELOPER'S LOT: LOT #31
4. TOPOGRAPHIC INFORMATION WAS COMPILED FROM
AN ON THE GROUND INSTRUMENT SURVEY.
5. TOWN WATER IS PROVIDED TO THE SITE & SURROUNDING PROPERTIES.
6. NO WETLANDS ARE LOCATED WITHIN 150 FEET OF THE PROPOSED SAS.
7. REFERENCE PLAN: DEED BOOK 20123 PAGE 7, PLAN BOOK 271 PG 81
8. UTILITIES LOCATED BY DIGSAFE #20191306988.
9. THIS DESIGN PLAN IS TO BE UTILIZED FOR SEPTIC REPAIR PURPOSES ONLY.
10. EXISTING SEPTIC COMPONENTS LOCATED PER THE AS—BUILT ON FILE AT BOARD OF HEALTH.
LEGEND
—W—
97.96 X
••••••••••18.- .••••
Existing contour
KNau
Existing 1,000 gal. H-10 loading
septic tank
I
I
Existing Leach Pit
................. ...............
,
I
Perk Test Location
LOT 31
AREA— 2 2
S 100•....-...
F. o
septic setbackP�//
99.
,198±
.
-
100.............................................................................................................................................................................................
X
B M :...........
C.B. 1 fn d. .....
...... .
. .......................................
98 .......................................... .............. ....................
------- 97.45------------------
........ .......................... — .... ........ ....
/
98'�
9
SITE
HOCKANOM "ROAD`S
SCALE.
,PLAN
1 — 20
a
AFIN
B.M.=100.00'
(ASSUMED)
PUBLIC — VARIABLE WIDTH
0.1
ON
C.B.1 FND.
_1 .0
i.
SITE
"YARMOUTHPORT"
it CIRCUIT
GENERAL NOTES
1. ADDRESS: 3 CONSERVATION DRIVE, YARMOUTH
2. ASSESSOR'S NUMBER: MAP 134 PARCEL 26
3. DEVELOPER'S LOT: LOT #31
4. TOPOGRAPHIC INFORMATION WAS COMPILED FROM
AN ON THE GROUND INSTRUMENT SURVEY.
5. TOWN WATER IS PROVIDED TO THE SITE & SURROUNDING PROPERTIES.
6. NO WETLANDS ARE LOCATED WITHIN 150 FEET OF THE PROPOSED SAS.
7. REFERENCE PLAN: DEED BOOK 20123 PAGE 7, PLAN BOOK 271 PG 81
8. UTILITIES LOCATED BY DIGSAFE #20191306988.
9. THIS DESIGN PLAN IS TO BE UTILIZED FOR SEPTIC REPAIR PURPOSES ONLY.
10. EXISTING SEPTIC COMPONENTS LOCATED PER THE AS—BUILT ON FILE AT BOARD OF HEALTH.
�tw •+4$
PROPOSED SEPTIC SYSTEM REPAIR
MATTHEW C. PREPARED FOR
s
COSTA
2 JANIS GOLD
� .
AT
s� n #3 CONSERVATION DRIVE
YARMOUTH, MA
OWNER: ANTHONY L. CRAPIS, C/O JANIS GOLD
PREPARED BY:
LEGEND
—W—
Approximate location
water line
••••••••••18.- .••••
Existing contour
KNau
Existing 1,000 gal. H-10 loading
septic tank
Existing Leach Pit
(to be pumped and backfilled)
101.70' X Denotes existing spot grade
Perk Test Location
�tw •+4$
PROPOSED SEPTIC SYSTEM REPAIR
MATTHEW C. PREPARED FOR
s
COSTA
2 JANIS GOLD
� .
AT
s� n #3 CONSERVATION DRIVE
YARMOUTH, MA
OWNER: ANTHONY L. CRAPIS, C/O JANIS GOLD
PREPARED BY:
Glen E. Harrington, R.S.
9 Leda Rose Lane
Marstons Mills, MA 02648
Tel: 774-238-1813
Email: gharr88®hotmail.com
SCALE: 1 "=20'DRAWN
BY: GEH
Vat
mouth Health Department
DATUM: ASSUMED
P V D
F,a
KNau
1 OF 2
Date
Glen E. Harrington, R.S.
9 Leda Rose Lane
Marstons Mills, MA 02648
Tel: 774-238-1813
Email: gharr88®hotmail.com
SCALE: 1 "=20'DRAWN
BY: GEH
DATE: 27
MAR 2019
DATUM: ASSUMED
FILE: 3ConservYarm
SHEET
1 OF 2
Existing Dwelling
SYSTEM PROFILE
*NOTE: ALL PIPES ARE TO BE 4" SCHEDULE 40 P.V.C.
First FI.=103.17'
Not to Scale
3 HOLE H-20
Existing Grade =95'f
DIST. BOX
Finished grade over system=2% slope away Existing Grade = 96't
CELLAR Septic tank covers must be
"
WALL within 6" of finished grade
----------------------------
D -Box cover shall be
within 6" of finished grade
One chamber cover shall be
in. 2"-1/8"-1/2" Double -Washed Stone
or eo-textile filter cloth
9
S = 0.02' ft
within 6" of finished
grade
To of SAS=93'
S=0.01'/FT.
Bsmt F1.=94.94' ''. 13' EXISTING
S=' ft
S=0.011/
0.01 ft
GAL.
2s'
Invert Elev.=91.84'
SEPTIC TANK
..
13' ® C3 EM
EUC3
r_3 CMP=91,97 24"
Inv. elev.= 98.49' " H-10
Ex.= 0'Bottom
® ® C3 ® ® ®
of Leach Facility Elev.=89.93'
Install Gas Baffle
or equal
Ex. Inv. Elev.=92.65'A.
P=92.14'
3/4"-11X" Double -Washed Stone
5'
Min. (5't PROVIDED)
6" OF 3/4"-11/2" STONE
LEACHING CHAMBERS
6" OF 3/4--11/2- STONE
MINIMUM Bottom of Test Hole Elev.=85.0'
ire"" One chamber cover shall be Min. 2"-1/8"-1/2" Double—Washed Stone
filter cloth
geo—teTor
Design Calculations
within 6" of finished grade
of SASxtile
.:: 2
.............................
Number of Bedrooms: 3 Equivalent to 330 Gal./Day
.�,,.,_._,..;.,_,:::,.:.,_......
. �������••:•�:::::::.
:::.:::...................
Garbage Disposal: Not allowed with this design
LR
Septic Tank Ca acit Required: 330 d x 200 - 660 d.
P Capacity q 9P - 9P
C3 C3 C3 0
24"
0
Septic Tank Capacity Provided: Existing 1,000 -gal H-10 septic Tank
O C3 r-3 G G G r_3 Bottom of Leach Facility Elev.B
r4!
Leaching Capacity Required: 330 gpd x LTAR= 446 SF Req'd Area
s' a'
BATH
N:
LTAR for Class I soil at <2 min./inch = 0.74 gal/sq. ft.
3/4"-1V"
/
Double—Washed Stone s' Mtn.
H-10
DR K
''''
EXISTINGr////;,
Proposed Leaching Structure: 1-25'x13'x2' Leaching Trench
P 9 9
Bottom Leaching Area Provided = 325 Sq.Ft.
LEACHING CHAMBERS
.•::1.3;:•::::
DWELL ING
/�'���
Sidewall Leaching Area Provided = 152 sq. ft.
Total Leachin Area Provided = 477 s . ft. > 446 s . ft re 'd.
9 q q qCROSS
SECTION
F elev.=103.17'
Leaching Capacity Provided =477 sq. ft X 0.74 gal/sq.ft.=353 gpd.
FIRST FLOOR
"""�����.......
B Fl.elev.—"
94.94'���� j
25'
SAS LAYOUT
MBR
>
Scale: 1 =20
...............................................................................
6
A
FIN N,
13 O 0
RM CL
HALL
A-1 = 43'-0" B-1 = 41'-5"
A-2 = 58'-8" B-2 = 41'-3"
BA
BR
BATH
BASEMENT LEVEL
CONSTRUCTION NOTES
SAS LAYOUT
SECOND FLOOR
OF
PLAN VIEW
1.
Contractor is responsible for Digsafe notification
and protection of all underground utilities and pipes.
�y
p G
NOT TO SCALE
2.
The septic tank and distribution box shall be set
level on 6" of 3/4"-11/2 stone.
AR ING N —'
3.
Backfill should be clean sand or gravel with no
® 0
stones over 3" in size.
PROPOSED SEPTIC SYSTEM REPAIR
4.
This system is subject to inspection during installation -
PERK TEST &SOIL
EVALUATION PERK TEST
�°f�-��Q•��
PREPARED FOR
by Glen E. Harrington, R.S.
Dote of TEST HOLE: APRIL 10, 2019 DEPTH: 39-57"
Performed By. GLEN E. HARRINGTON, R.S.
1TAF0
JANIS GOLD
5.
The contractor shall install this system in accordance
BEGIN SOAK: 00:00
Witness: AMY VON HONE, R.S., BOH AGENT END SOAK: 11:05 min:sec
AT
with Title V of the Massachusetts Environmental Code
and local Board of Health Rules and Regulations.
Excavator: BRUCE, CAPEWIDE ENTERPRISES
Percolation Rate: < 2 MPI
TIME: 11 MIN.=UNABLE TO SOAK
USE <2 MPI FOR DESIGN
#3 CONSERVATION DRIVE
6.
If, during installation the contractor encounters any
Test Hole
Test Hole Test Hole
Test Hole
YARMOUTH, MA
soil conditions or site conditions that are different
No. 1
DEP soils ELEV.
No. 2 No. 3
ELEV. DEPTH SOILS ELEV.
DEPTHr�EBW
No. 4
OWNER: ANTHONY L. CRAPIS, C/0 JANIS GOLD
from those shown on the soil log or in the design,
^
^ 1 or,"
"
DEP SOILS ELEV.
the installer shall halt installation and immediately notify
D/A
0/A
TKY
o/A
PREPARED BY:
Glen E. Harrington, R.S.
loamy
sand
loamy
sand
loamy
7.
NO vehicle Or heavy machinery shall drive over the
10YR4 1 5.1
" 5.2 ' 10YR4 1
sand
90YR4 1
Glen E. Harrington, R.S.
g
septics stem unless noted as H-20 septic components.
Y P P
Ioam
sandy
BW
oom
sandy
tom,9
Leda Rose Lane
8.
All piping shall be 4"diameter SCH 40 PVC unless otherwise specified. ^ .5YRs
^ .5YR5 ^ .5YR5
sandy
" .5YR5
Marstons Mills, MA 02648
9.
No wells are located within 150' of proposed SAS.
c1
92.5'
c1 c1
c1
Tel: 774-238-1813
10.
Provide 1 DB -3 H-20 d—box and 2 H-10 500— al concrete
g
MEDIUM
SAND
MEDIUM �Q MEDIUM
SAND SAND
MEDIUM
Email: gharr880hotmail.com
chambers by Wiggin Precast or equal.
2.5Y6/4
2.5Y6/4 910' 2.5Y6/4
SAND
2.5Y6/4
11.
Existing leach pit shall be pumped and backfilled.
NO GROUNDWATER ENCOUNTERED NO GROUNDWATER ENCOUNTERED NO GROUNDWATER ENCOUNTERED NO GROUNDWATER ENCOUNTERED
SCALE: 1"=20' DRAWN BY: GEH DATE: 27 MAR 2019
DATUM: ASSUMED FILE: 3ConservYarm SHEET 2 OF 2