Loading...
HomeMy WebLinkAboutReview Checklist F TOWN OF YARMOUTH 6 7 Al?SEWAGE PLAN REVIEW CHECKLIST 1 Location: AM 7 LOT Date of Subdivision Approval g 7F-d 5-/g----- Street Street / i /.57Z) ' Zone of Contribution: In ?C' Out Village C c% .‘/ Commercial Residential Owner: ��� ,1.(. Installer "6 d v Builder: Engineer � __/ c (i i� N/A YES NO 1. Required number of copies received. . 2. Date of soils exam and percolation test not older than 2 years. e// 3. 4 feet of naturally occurring pervious material, above water table(new construction) ,/ 4. Foundation 2 feet above high point of fronting road for new construction. / 5. Water availability letter from Water Department for new construction. ✓/. 6. Benchmark indicated and shown- NGVD if near wetlands. ..// 7. Building sewer does not exit center of house. ✓�/ 8. Septic tank a minimum of 10 feet from house and deck. V 9. Leaching a minimum of 20 feet from house and 10 feet from deck. 10. Leaching a minimum of 100 feet from wetlands. / 11. Leaching a minimum of 150 feet from drinking wells/25 feet from irrigation wells. r/ y 12. System meets all other setback requirements. /V 13. Uses adjustment for maximum high groundwater. t/ / 14. Leaching 4 -5 feet above adjusted water table or bottom of test pit. V 15. System not in top or subsoil or 5 foot removal. / 16. Proposed contours are suitable. 1/ 17. System meets slope requirements - min. 1/8". 1/4" preferred. 18. System meets breakout requirements- peastone elevation carried out 15 feet minimum. 19• Specified tee sizes are proper. gas baffle on outlet tee. / 20. Sewage Clow under 10.000 gpd for parcel. ✓/ 21`No garbage disposal. / 22.tSvstem adequately sized for its intended use. ✓/ 23. Minimum 6" stone or mechanically compacted below the tank and d-box. 24. Manhole covers within 6" of grade - septic tank and pump chamber. ✓ 25. Electrical permit for pump chamber. 26. Pump system - 2" lines weep hole, check valve, sanitary in d-box. alarm on separate circuit.✓ 27. Septic tank and pump chamber to be Factory waterproofed. 28. Vent provided if leaching below 3 feet or under driveway or parking. J 29. Engineer to inspect and certify : a. clay removal (.1) b. wall construction schedule C// c. commercial system 30. Engineer and Land Surveyor stamp and signature. /31. H2O loading when system subject to vehicular traffic. ../ / 32. Title V application and fee signed by a licensed installer. / V33. Foundation footing 2 feet above adjusted water table. i/ . 34. Lot subdivided prior to July 31. 1986 - Nitrate Loading, 35. Subdivided prior to April 7, 1989 - Phosphorus ' one 300'. Plan reviewed by: I