HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
// SEWAGE
PLAN REVIEW CHECKLIST
7 Location: A.M. !43 Lot .7'3 Zone of Contribution: In Out acreage
1" ---/%'f Commercial: Residential: (---
Street: _.7:1//
Village:
V2/ Floor Plan: (.' #Bedrooms:_
Owner: j fk(ey.17 Installer: A es.,-/p/14-t, �,
Address: Phone: / -7/,
Phone: 7' c /, d ��
Gdr! lads
Builder: Engineer: f,S ���' / Y
Address: / Phone: 4%
Phone: /
N/A YES NO
1.Required#of copies received
2. Date of soils exam and percolation test not older than 2 years L.---'
3. 4-5 ft of naturally occurring pervious material, above water table t-----
4.
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: t.....----
5.
/5. Water line 10 ft from septic components Var.: lam''
6.Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: L .----
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: C c.--
9.
9.Leaching minimum 100 ft from wetlands Var.: `_/
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11. Tank/leaching minimum 10 ft from property line Var.: Cam
12. System meets all other setback requirements Var.: L----
13.Uses adjustment for maximum high groundwater Var.: :- ` �o
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.= ���'1� 4
15. System not in top or subsoil(A,B horizons)or 5' removal t--
16.Proposed contours are suitable L----
17. System meets slope requirements-min. 1/8", 1/4"preferred L.---
18. System meets breakout requirements PVC liner: Wall: 1------
19.
/19. Specified tee sizes are proper, gas baffle on outlet tee L.-------
20. Sewage is under 10,000 gpd for parcel t-----•
21.No garbage disposal f
22. System adequately sized for its intended use (..---
23.Minimum 6"stone or compacted below tank and dbox .
' 24.Manhole covers within 6"of grade,pump chamber cover to grade L_-
25. Inspection port on plastic chambers/leach field Ls
26.Electrical permit for pump chamber/Separate meter for duplexes -.......-
27.
�27.Pump system-2" line,weep hole,check valve,tee in dbox, pump size L✓
28. Septic tank/pump chamber to be factory waterproofed `....----
29.Vent provided if leaching below 3 feet, under driveway/parking l-,y,
30. Buoyancy calculations for tank/pump chamber k......----
31.Engineer to inspect and certify soils: wall: commercial: %-_,..---
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature �_.---
33. H-20 loading is subject to vehicular traffic, groundwater ts•
34.Title V Application and permit fee, installer signature - \---__,„
35.Foundation footing min. 2 feet above adjusted ground water for new house
36. Deed Restriction required max. #bedrooms: max. flow: gpd �-
37. Check area lots for groundwater/Label groundwater in Assessor's Ma
Plan reviewed by: - 6/03/03