Loading...
HomeMy WebLinkAboutEngineered Plan - 201995,36 — — 98 — — EXISTING CONTOUR LOCUS N x 100.98 EXISTING SPOT GRADE W PROPOSED WATER SVC. G EXISTING GAS SERVICE � r Rood BENCHMARK. 95.93OVERHEAD WIRES yg��o yF S TEST PIT z 62 � �, MANETIC NAIL SET -1 ,T BENCHMARK St EL.=9725 CTMh�i".'1.h.r ^h F ti Pon N LEGEND so0..;,. ... oooy / ROUTE 6 2 96.711 97,, 97,06/ 9 � EXISTING LEACH PIT 91.31 / �PUMPED, FILLED EAND ABANDONED OR <u / / /l SANDE ` x 99.0 INSPECTION PORT LOCUS MAP REMOVED4`8, Q745 NOT TO SCALE ' /1 & _X 100,0•��St' :" `�` 0` 9 °5 e 97,92 GENERAL NOTES: EXISTING SEPTIC TANK JA38,27/ ^p / 0) 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL TOP OF TANK, EL.=103.8E / / - - LA 8 BOARD OF HEALTH AND THE DESIGN ENGINEER. e INV (OUT)=102.45f(>/ERIFY) r 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS _ � �.`�° 1 � � OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE 103,64 \ LOCAL RULES AND REGULATIONS EXCEPT AS REQUESTED BELOW: 10 310 CMR 15.4050)(b): VENT 2) A 2' variance to the 3' maximum cover requirement, for up 99,32 H-20 Rated. S to 5' of cover. S.A.S. shall be vented and 68 yKFILLED .:; 0 / / r / O PRIOR ,. 99,56' 3 TOEINSPECTION SEWAGE I AND APPROVASPOSAL L BY BY THE SHALL NBOARD OFOT BE CHEALTH AND THE 0 •� 8�O 0 i%� 104,29 10439 DESIGN ENGINEER. // P \ q 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING SHOWN HEREON SHALL BE REPORTED TO THE DESIGN 99,6-.'.... 99.57;; .:..:.:::::.:: ::;:. ;, FROM THOSE ENGINEER BEFORE CONSTRUCTION CONTINUES. EXISTING X 105,6 3 HOUSE(#171) co 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF / T.0.F.=107.56E ��o' O THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 9 o / / GARAGE X N 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 106.1 1 V) Ed / / / / \ Uj 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 1 00,241 It gyp/ / / / / 1 / 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS /\ AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE Z / / ' x 106 8 DIRECTED BY THE APPROVING AUTHORITIES. !/ `� OF MASS9 104,46 X 105 PATIO �\�` 1 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY DECK 8,37 �yG THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING X 104,64 ��cQ G6-_ _ o PETER T. CONSTRUCTION. 106,16 pail \ o MCENTEE N 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS . * � { re v CIVIL IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND / / .04 No. 35109 REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). ✓ X 107,67 i /S1 �� 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND - r X 109,66 X 109 / A \ IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. va r REPAIR O �P , - - - _X_ - Per-,t,�. PARCEL !D: 116-86 ONLY, dire to d I,< cal Xe SP/PTJ i t es.108,04 108,37 �} 1 I L � l � 4' Board of flealth re 191 ;1Iip +A .elui d for LOT 19 + � PLAN REFERENCE: CERTIFIED PLOT PLAN BY CRAIG SHORT DATED MAY 25, 1983 any future additi. r.Q jour . air, ns to sewage facilities and/or sir 6tt� e,idwe 19,294± S.F. X19 86 PROPOSED SEPTIC SYSTEM UPGRADE PLAN ,� Yarmouth Health Deli rt" ► -ent �F �5 w ��•3�171 WEIR ROAD, YARMOUTH PORT, MA �. �% APPRE) i` E Prepared for: Michael Harris, 171 Weir Road, Yarmouth Port, MA 02675 < .64 OWNER OF RECORD Engineering by: SCALE DRAWN JOB. NO. HARRIS -WARREN, CHARLES M Engineering Works, Inc. 1 "=20' P.T.M. 160-19 Z 171 WEIR ROAD 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET N0. ame' Dat YARMOUTH PORT, MA 02675 (508) 477-5313. 4/12/19 P.T.M. 1 Of 2 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:98.8 FOR A DISTANCE OF 15' AROUND THE SEPTIC TANK PROPOSED D -BOX PERIMETER OF THE S.A.S. INSTALL RISERS & COVERS OVER INLET & DECK INSTALL RISER & COVER OUTLET AND SET TO 6" OF FINISH GRADE PROPOSED S.A.S. SET TO 6" OF GRADE INSTALL INSPECTION PORT OVER ONEH ROW N.) 7GE T.O.F.=107.61 CHARCOAL F.G. EL.=106.41 F.G. EL.=104.3± F.G. EL.=98.0± F.G. EL.=98.3 to 101.3± VENT CONNECT MAINTAIN 2% GRADE MIN. OVER S.A.S. ALL ROWS ` L = 57' INSPECTION ® S=1% (MIN.) ® S=1% (MIN.) PORT �l J 4"SCH40 PVC 4"SCH40 PVC -: 0 711 1 EX�SnNG to„I 74" 8" HOUSE(#171) 71&ETRO���� EXISTING a8" LIQUID�LEVEL3 SAFFLE INV.=96.17 PD INV.=9INV.=102.45± ROWS OF 7 UNITS AT 6.25'/UNIT = 43.8'GAs INV.=. EXISTING 3 OLD-Ja�ETS SOIL ABSORPTION SYSTEM PROFILE; H-20 EXISTING SEPTIC TANK WITH INLET TEE ESTABLISH VEGETATIVE COVER - 62.8, .9 BACKFILL WITH NATIVE ORPERC 69 \` SAND TO TOPA OF CHAMBERS 6' G� NOTES: BREAKOUT=TOP 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE TOP ELEV.=96.33 i. . '•,�. :: `;' �` ,.; .;� • : MAGNETIC NAIL SET M- cS / / cS. d,, �t // INVERTS, PRIOR TO INSTALLATION. INV.=95.92 2) D -BOX SHALL BE SET LEVEL AND TRUE TO BOTTOM ELEV.=95.00 �llll�lllll /00 PS / do // GRADE ON A MECHANICALLY COMPACTED SIX 5' MIN. SEPARATION 2.83' 6" 6" Q05�' / pR0 INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). TO GROUNDWATER // �•+j8 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 4' (MIN.) OF NATURALLY OCCURRING PERVIOUS SOILS EFFECTIVE WIDTH=9.5' SUITABLE SOILS ; /// / 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE NO G.W., EL=89.0 S.A.S. LAYOUT AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. = USE 3 ROWS OF 7 -HIGH CAPACITY H-20 INFILTRATOR UNITS a000000 0000000 WITH 6" SEPARATION BETWEEN EACH ROW & NO STONE SEPTIC SYSTEM PROFILE TYPICAL sECTION 0000000alI 100000000 28"--I SOIL LOG Closed End Plate Open End Plate DESIGN CRITERIA DATE: APRIL 10, 2019 SOIL EVALUATOR: PETER McENTEE PE(SE#1542) NUMBER OF BEDROOMS: 4 BEDROOMS WITNESS: AMY VON HONE R.S. HEALTH AGENT SOIL TEXTURAL CLASS: CLASS I- ELEV. TP DEPTH Z'- - DESIGN PERCOLATION RATE:0" <5 MIN/IN 100.0 A 16" DAILY FLOW: 440 GPD LOAMY SAND �I , 75" �-- 34" DESIGN FLOW: 440 GPD 10YR 4/2 99.0 12" 1.25" GARBAGE GRINDER: NO B LOAMY SAND Side View End View EXISTING SEPTIC TANK: 1000 GALLON CAPACITY 10YR 5/8 32„ 97.3 HIGH CAPACITY INFILTRATORS, H-20 LOADING LEACHING AREA REQUIRED: (440 GPD) = 594.6 SF C L PERC INFILTRATOR CHAMBERS .74 GPD/SF 26"/44" DISTRIBUTION BOX: 1 INLET, 4 OUTLETS (MINIMUM) H-20 PROPOSED SEPTIC SYSTEM UPGRADE PLAN M -C SAND USE 3 ROWS OF 7. HIGH CAPACITY INFILTRATOR H-20 UNITS, WITH 10YR 6/4 171 WEIR ROAD, YARMOUTH PORT, MA NO STONE. SPACED 6" BETWEEN ROWS. FOR A 9.5' x 43.8' BED SIDEWALL AREA: NOT APPLICABLE Prepared for: Michael Harris, 171 Weir Road, Yarmouth Port, MA 02675 BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF) Engineering by: SCALE DRAWN JOB. NO. (INFILTRATORS) 21 UNITS x 6.25 LF x 4.73 SF/LF = 620.81 SF 89.0132„ Engineering Works, Inc. N.T.S. P.T.M. 160-19 DESIGN FLOW PROVIDED: 0.74 GPD/SF(620.81 SF) = 459.4 GPD PERC RATE <2 MIN/IN. "C" HORIZON 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO. NOMINAL BED AREA: 9.5' x 43.8' = 416.1 SF (400 SF REQ'D) NO GROUNDWATER ENCOUNTERED (508) 477-5313 1 4/12/19 P.T.M. 2 Of 2