Loading...
HomeMy WebLinkAboutReview Checklist • g-i3 ~-(2 • TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST d �2 Location: A.M. 7 .7 Lot -3 7 Zone of Contribution: In Out Acreage/ ,, 2- 9 ` \ ( � caal‘47 Commercial: Residential:Street: l L �"Village: K1, Floor Plan: C #Bedrooms: 3 Owner: 9/(2-eolil�l°l/~ Installer: 7 / `/Z 4t I Address: Phone: Phone: Builder: Engineer: 4,41�!71 -4 Address: Phone: l-- ' A--'z i ,K 1 r t56 Phone: �44% - ti,deete7 N/A YES ATO 1.Required#of copies received i.-------- 2.Date of soils exam and percolation test not older than 2 years ✓' 3.4-5 ft of naturally occurring pervious material,above water table L.✓ 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: •------- 5.Water line 10 ft from septic components Var.: l_._...---- 6. _„r6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: _--- 9.Leaching minimum 100 ft from wetlands Var.: t-- 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ___.---- 11. ---'"11.Tank/leaching minimum 10 ft from property line Var.: 'ter' 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: t j� +I f 0,t.-- 14.Leaching set 4-5 ft above adj. water or botto ii : .: - Var.: �',/ 15. System not in top or subsoil(A,B horizons) o 'remo : ,.... *----- 16. r16.Proposed contours are suitable L------ 17. System meets slope requirements-min. 1/8", ' "preferred 1../". 18. System meets breakout requirements PVC liner: Wall: •(r/ 19. Specified tee sizes are proper, gas baffle on outlet tee t 20. Sewage is under 10,000 gpd for parcel t 21.No garbage disposal ' 22. System adequately sized for its intended use i----- 23.Minimum 6"stone or compacted below tank and dbox .__-_ 24.Manhole covers within 6"of grade,pump chamber cover to grade 25.Inspection port on plastic chambers/leach field c_------ 26.Electrical permit for pump chamber/Separate meter for duplexes ;,„,..- 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size u' 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet, under driveway/parking 30.Buoyancy calculations for tank/pump chamber .....---- 31.Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater 34. Title V Application and permit fee, installer signature �(+ _ 35.Foundation footing min. 2 feet above adjusted ground water for new house -----r 36.Deed Restriction required max. #bedrooms: ...___max. flow:2 .-(�' gpd 37.Check area lots for groundwater/Label groundwater in Assessor's MapL.----'' Plan reviewed by: 6/03/03