Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE FLAN REVIEW CHECKLIST F Location: AM./1,3 LOT /9 Date of Subdivision Approval Street // (/ .ild7( � Zone of Contribution:In Out Village iICommercial Residential Owner: iiic. .///7"0(-111441-01Installer rktv, ef'-i''''L. Builder: Engineer . -Fie/ii ,litik N/A YES NO 1.°Required number of copies received. 1...-- 2. .�2. Date of soils exam and percgbijpn test not.okier tla n 2<years. 3. 4 feet of naturally occumiraervious material. above water table(new constriction) `� 4. Foundation 2 feet above int of from road for new construction. 5. Water availability letter from for new construction. t� 6. Benchmark indicated and shown-NGVD if near wetlands. v✓ 7. Building sewer does not exit center ofhouse. t. 8. Septic tank a minimum of 10 feet from_house and deck. a al's nradP ✓ 9. Leaching a minimum of 20 feet from house and 10 feet from deck. ✓ 10. Leaching a minimum of 190 feet from wetland. +7 11. Leaching a minimum of 150 feet from drinking wells/25 feet from irrigation wells? 12. System meets all other set•. , a 11 t 1, . e• c Y a✓ 13. Uses adiusttnent for maximum- • - 14. Leaching 4-5 feet above = •"� i -• water ; e • bottom of test pit. j r 6/04-4;4441 L✓ 15. System not in,top or su.. .' 5 foot t 11 r. 16.Proposed contours are suitable. 17. System meets slope requirements-min 1/8". 1/4"preferred. 18. System meets breakout requirements-past_one elevation carried out 15 *et minimum. _ _ 19. Specified tee sizes are proper. �r__ baffle on outlet tee. ✓ 20,,Sewage flow under 10.000 '41 . for parcel. > 21. No garbage disposal. ad1 ��ysteln e�uately sized for its intended use � ., , 23/Minimum 6 ,stone or mechanically compacted below the tank and d-box. ✓^ '. 24. Manhole covers within 6"olgrade-stink tank and pump chamber: L.-! 25. Electrical per for pump chamber. ../ 26. Pumas ystem-2 line.weep bole-check valve. sanitart ind-bax.aeon separate circuit. 27. Septic tank andpump c .. •: to be Factory watfed. L✓ i 28. Vent provided f leaching .. w 3 feet or under driveway or parking. ✓ 29, Engineer to inspect and certify: a.clay removal b.wall construction schedule � CI II ialy1.i -It _ t_'• - e_t• _��.L .10 '1_r_1111 t 1,* 7141A I. � ( * • i1 . 1 1 '1 t-7 t1 '1_ • �?l • L ! _ tr• ' 32. Title V a• • ication and fee sig 'by a licensed installer. 33. Foundation footing-2 feet above adjusted water table. L✓ 34. Lot subdivided prior to July 3 L 1986 -Nitrate Loading. 35. Subdivided prior co April 7_1989-.Phosphorus Zone 300'. Plan reviewed by: 0